Quantitative analysis calibration

Three methods are used for quantitative analysis calibration curves, empirical coefficients, and fundamental parameters. [Pg.436]

For the quantitative analysis calibrated sensitivity factors, obtained from pure oxides, were used. These were 0 Is = 1, Ti... [Pg.122]

Quantitative Analysis calibration using external standard mode spiked recovery no write-up required... [Pg.473]

The raw Crystaf profile provides information about the distribution of crys-tallizabilities of the polymer sample that can be correlated to molecular structure with the use of a proper calibration curve. Contrary to SEC, there is no universal calibration curve for Crystaf for quantitative analysis, calibration curves should be prepared with narrow standards that have microstructures as similar as possible to the sample being analyzed. [Pg.3359]

Using the flame ionization detector and temperature programming Veening et al obtained results quoted in Table 149 for a mixture of five areue tricarbonylehromiurn compounds. Except where indicated the mesitylene compound was used as reference compound for quantitative analysis. Calibration curves for all four constituents were linear between 1.0 x 10 and 1.0 x 10 g/ml. From the results in Table 149 it can be seen that the accuracy of the method is good to within i 3.2% relative error. Table 149 also tabulates results obtained for benzene and mesitylene tricarbonylchromium using an electron capture detector and 2-bromonapthalene as internal standard. [Pg.498]

Equations 10.4 and 10.5, which establish the linear relationship between absorbance and concentration, are known as the Beer-Lambert law, or more commonly, as Beer s law. Calibration curves based on Beer s law are used routinely in quantitative analysis. [Pg.386]

Quantitative Analysis for a Single Analyte The concentration of a single analyte is determined by measuring the absorbance of the sample and applying Beer s law (equation 10.5) using any of the standardization methods described in Chapter 5. The most common methods are the normal calibration curve and the method of standard additions. Single-point standardizations also can be used, provided that the validity of Beer s law has been demonstrated. [Pg.400]

The slope of the calibration curve is found to be -57.98 mV per tenfold change in the concentration of F , compared with the expected slope of-59.16 mV per tenfold change in concentration. What effect does this have on the quantitative analysis for %w/w Snp2 in the toothpaste samples ... [Pg.490]

If the rate is measured at a fixed time, then both k and are constant, and a calibration curve of (rate)f versus [A]o can be used for the quantitative analysis of the analyte. [Pg.630]

Of course, the most reliable and accurate method of quantitative analysis is to calibrate each element with standards prepared in matrices similar to the unknown being analyzed. For a survey technique that is used to examine such a wide variety of materials, however, standards are not available in many cases. When the technique is used mainly in one application (typing steels, specifying the purity of alloys for a selected group of elements, or identifying impurities in silicon boules and... [Pg.604]

Kinetic methods. These methods of quantitative analysis are based upon the fact that the speed of a given chemical reaction may frequently be increased by the addition of a small amount of a catalyst, and within limits, the rate of the catalysed reaction will be governed by the amount of catalyst present. If a calibration curve is prepared showing variation of reaction rate with amount of catalyst used, then measurement of reaction rate will make it possible to determine how much catalyst has been added in a certain instance. This provides a sensitive method for determining sub-microgram amounts of appropriate substances. [Pg.10]

We will explore the two major families of chemometric quantitative calibration techniques that are most commonly employed the Multiple Linear Regression (MLR) techniques, and the Factor-Based Techniques. Within each family, we will review the various methods commonly employed, learn how to develop and test calibrations, and how to use the calibrations to estimate, or predict, the properties of unknown samples. We will consider the advantages and limitations of each method as well as some of the tricks and pitfalls associated with their use. While our emphasis will be on quantitative analysis, we will also touch on how these techniques are used for qualitative analysis, classification, and discriminative analysis. [Pg.2]

In the context of the stability of the nitrosoamine intermediate in the diazotization of heteroaromatic amines relative to that in the case of aromatic amines, the reversibility of diazotization has to be considered. To the best of our knowledge the reverse reaction of a diazotization of an aromatic amine has never been observed in acidic solutions. This fact is the basis of the well-known method for the quantitative analysis of aromatic amines by titration with a calibrated solution of sodium nitrite (see Sec. 3.3). With heteroaromatic amines, however, it has been reported several times that, when using amine and sodium nitrite in the stoichiometric ratio 1 1, after completion of the reaction nitrous acid can still be detected with Kl-starch paper,... [Pg.62]

Because of peak overlappings in the first- and second-derivative spectra, conventional spectrophotometry cannot be applied satisfactorily for quantitative analysis, and the interpretation cannot be resolved by the zero-crossing technique. A chemometric approach improves precision and predictability, e.g., by the application of classical least sqnares (CLS), principal component regression (PCR), partial least squares (PLS), and iterative target transformation factor analysis (ITTFA), appropriate interpretations were found from the direct and first- and second-derivative absorption spectra. When five colorant combinations of sixteen mixtures of colorants from commercial food products were evaluated, the results were compared by the application of different chemometric approaches. The ITTFA analysis offered better precision than CLS, PCR, and PLS, and calibrations based on first-derivative data provided some advantages for all four methods. ... [Pg.541]

The set of possible dependent properties and independent predictor variables, i.e. the number of possible applications of predictive modelling, is virtually boundless. A major application is in analytical chemistry, specifically the development and application of quantitative predictive calibration models, e.g. for the simultaneous determination of the concentrations of various analytes in a multi-component mixture where one may choose from a large arsenal of spectroscopic methods (e.g. UV, IR, NIR, XRF, NMR). The emerging field of process analysis,... [Pg.349]

D.M. Haaland, Multivariate Calibration Methods Applied to the Quantitative Analysis of Infrared Spectra, Chapter I in Computer-Enhanced Analytical Spectroscopy, Volume 3", edited by P.C. Jurs. Plenum Press, New York, 1992. [Pg.381]

Quantitative analysis is performed by the calibration technique. A new calibration curve with a standard solution of each diphenyl ether herbicides is constructed, plotting the peak area against the amount of standard solution injected. Each diphenyl ether herbicide in the sample is measured by using the peak area for each standard. Before each set of measurements, the GC and HPLC system is checked by injecting more than one standard solution containing ca 0.01-2 mg L of each compound. [Pg.457]

Internal rather than external standards are recommended for quantitative analysis. If standard additions are used for calibration all the parameters listed in this table must be held constant. [Pg.128]

The determination of the relationship between detector response and the sample concentration is termed the calibration of the method. There are two types of methods in use for the quantitative analysis of a sample, i.e., the external standard and the internal standard method. An external standard method is a direct comparison of the detector response of a pure compound (standard) to a sample.2 The calibration of the method is performed by preparing standards of varying concentration and analyzing them by a developed method. Method 1 (below) was developed for toluene, and standards of varying concentration were prepared and analyzed. The results obtained are summarized in Table 2 see Figure 3. [Pg.156]

In direct insertion techniques, reproducibility is the main obstacle in developing a reliable analytical technique. One of the many variables to take into account is sample shape. A compact sample with minimal surface area is ideal [64]. Direct mass-spectrometric characterisation in the direct insertion probe is not very quantitative, and, even under optimised conditions, mass discrimination in the analysis of polydisperse polymers and specific oligomer discrimination may occur. For nonvolatile additives that do not evaporate up to 350 °C, direct quantitative analysis by thermal desorption is not possible (e.g. Hostanox 03, MW 794). Good quantitation is also prevented by contamination of the ion source by pyrolysis products of the polymeric matrix. For polymer-based calibration standards, the homogeneity of the samples is of great importance. Hyphenated techniques such as LC-ESI-ToFMS and LC-MALDI-ToFMS have been developed for polymer analyses in which the reliable quantitative features of LC are combined with the identification power and structure analysis of MS. [Pg.409]

Conventional XRF analysis uses calibration by regression, which is quite feasible for known matrices. Both single and multi-element standards are in use, prepared for example by vacuum evaporation of elements or compounds on a thin Mylar film. Comparing the X-ray intensities of the sample with those of a standard, allows quantitative analysis. Depending on the degree of similarity between sample and standard, a small or large correction for matrix effects is required. Calibration standards and samples must be carefully prepared standards must be checked frequently because of polymer degradation from continued exposure to X-rays. For trace-element determination, a standard very close in composition to the sample is required. This may be a certified reference material or a sample analysed by a primary technique (e.g. NAA). Standard reference material for rubber samples is not commercially available. Use can also be made of an internal standard,... [Pg.632]

XRF nowadays provides accurate concentration data at major and low trace levels for nearly all the elements in a wide variety of materials. Hardware and software advances enable on-line application of the fundamental approach in either classical or influence coefficient algorithms for the correction of absorption and enhancement effects. Vendors software packages, such as QuantAS (ARL), SSQ (Siemens), X40, IQ+ and SuperQ (Philips), are precalibrated analytical programs, allowing semiquantitative to quantitative analysis for elements in any type of (unknown) material measured on a specific X-ray spectrometer without standards or specific calibrations. The basis is the fundamental parameter method for calculation of correction coefficients for matrix elements (inter-element influences) from fundamental physical values such as absorption and secondary fluorescence. UniQuant (ODS) calibrates instrumental sensitivity factors (k values) for 79 elements with a set of standards of the pure element. In this approach to inter-element effects, it is not necessary to determine a calibration curve for each element in a matrix. Calibration of k values with pure standards may still lead to systematic errors for unknown polymer samples. UniQuant provides semiquantitative XRF analysis [242]. [Pg.633]

Whereas the use of conventional fast atom bombardment (FAB) in the analysis of polymer/additive extracts has been reported (see Section 6.2.4), the need for a glycerol (or other polar) matrix might render FAB-MS analysis of a dissolved polymer/additive system rather unattractive (high chemical background, high level of matrix-, solvent- and polymer-related ions, complicated spectra). Yet, in selected cases the method has proved quite successful. Lay and Miller [53] have developed an alternative method to the use of sample extraction, cleanup, followed by GC in the quantitative analysis of PVC/DEHP with plasticiser levels as typically found in consumer products (ca. 30 %). The method relied on addition of the internal standard didecylphthalate (DDP) to a THF solution of the PVC sample with FAB-MS quantitation based on the relative signal levels of the [MH]+ ions of DEHP and DDP obtained from full-scan spectra, and on the use of a calibration curve (intensity ratio m/z 391/447 vs. mg DEHP/mg DDP). No FAB-matrix was added. No ions associated with the bulk of the PVC polymer were observed. It was... [Pg.702]

Goodacre, R. Neal, M. J. Kell, D. B. Rapid and quantitative analysis of the pyrolysis mass spectra of complex binary and tertiary mixtures using multivariate calibration and artificial neural networks. Anal. Chem. 1994, 66,1070-1085. [Pg.339]

Timmins, E. M. Goodacre, R. Rapid quantitative analysis of binary mixtures of Escherichia coli strains using pyrolysis mass spectrometry with multivariate calibration and artificial neural networks J. Appl. Microbiol. 1997,83, 208-218. [Pg.340]


See other pages where Quantitative analysis calibration is mentioned: [Pg.106]    [Pg.261]    [Pg.106]    [Pg.261]    [Pg.389]    [Pg.453]    [Pg.154]    [Pg.286]    [Pg.491]    [Pg.79]    [Pg.230]    [Pg.174]    [Pg.120]    [Pg.697]    [Pg.145]    [Pg.148]    [Pg.290]    [Pg.278]    [Pg.16]    [Pg.130]    [Pg.202]    [Pg.444]    [Pg.636]    [Pg.655]    [Pg.176]   
See also in sourсe #XX -- [ Pg.292 ]




SEARCH



Calibration analysis

Quantitative Analysis Using Calibration Graph Method

Quantitative analysis calibration graph method

Quantitative analysis calibration methods

Quantitative analysis multivariate calibration