Pumps INDEX

Friatec, 2012. http //www.friatec.com/content/friatec/en/Mechanical-Engineering/Pumps/index. html lan given content=Hit Mat matid=7. [Pg.356]

The guarded hot-plate method can be modified to perform dry and wet heat transfer testing (sweating skin model). Some plates contain simulated sweat glands and use a pumping mechanism to deUver water to the plate surface. Thermal comfort properties that can be deterrnined from this test are do, permeabihty index (/ ), and comfort limits. PermeabiUty index indicates moisture—heat permeabiUty through the fabric on a scale of 0 (completely impermeable) to 1 (completely permeable). This parameter indicates the effect of skin moisture on heat loss. Comfort limits are the predicted metaboHc activity levels that may be sustained while maintaining body thermal comfort in the test environment. [Pg.461]

Another distinction in impellers is the way the liquid traverses and leaves the impeller blades. This is called the Specific Speed, Ns. It is another index used by pump designers to describe the geometry of the impeller and to classify impellers according to their clesign type and application. By definition, the Specific Speed, Ns is the revolutions per minute (rpm) at which a geometrically similar impeller would run if it were of such a size as to discharge one gallon per minute at one foot of head. [Pg.73]

The Specific Speed is a dimensionless number using the formula above. Pump design engineers consider the Ns a valuable tool in the development of impellers. It is also a key index in determining if the pump... [Pg.73]

Several sources (References 19. 20, 21, and 22) are available for estimating pumps and drivers to check in-house coiTelations or to fill in w here data is not available. Care must be exercised in using construction cost indexes to update the literature data. It would be w ise to calibrate the indexes and literature data by getting vendor prices on a few of the larger, more expensive pumps, and 5% or 10% of the common types of pumps in the project being estimated. [Pg.233]

For acrylate polymers with higher levels of carboxylic acids, THF can be modified by the addition of acids such as acetic, phosphoric, or trifluoroacetic. Levels as high as 10% acetic acid are considered acceptable by most manufacturers for their styrene/DVB columns. If such a modified mobile phase is used, it may need to be premixed rather than generated using a dynamic mixing HPLC pump because on-line mixing often leads to much noisier baselines, particularly when using a refractive index detector. [Pg.553]

The hazard index for acute exposure to the emissions near tlie pumps is ... [Pg.415]

In California, a Iiazard index greater tlian 0.5 is considered to be significant. Tlicrcforc, if. xj lcnc was tlie only contaminant at tlie gas station, the long tcnii exposure could be considered liazardous, but the sliort tenn exposure to the emissions near tlie pump niiglit not. [Pg.415]

Type specific speed is defined as that operating specific speed that gives the maximum efficiency for a specific pump and is the number that identifies the pump type [25]. This index number is independent of the rotative speed at which the pump is operating, because any change in speed creates a change in capacity in direct proportion and a change in head that varies as the square of the speed [25]. Practice is to true type the specific speed of the pump reasonably close to the conditions of maximum effi-... [Pg.194]

Refractive index detectors. These bulk property detectors are based on the change of refractive index of the eluant from the column with respect to pure mobile phase. Although they are widely used, the refractive index detectors suffer from several disadvantages — lack of high sensitivity, lack of suitability for gradient elution, and the need for strict temperature control ( + 0.001 °C) to operate at their highest sensitivity. A pulseless pump, or a reciprocating pump equipped with a pulse dampener, must also be employed. The effect of these limitations may to some extent be overcome by the use of differential systems in which the column eluant is compared with a reference flow of pure mobile phase. The two chief types of RI detector are as follows. [Pg.225]

For both reactions studied, NO+CO and NO+propene, the effect of electrochemically pumped Na in increasing the extent of NO dissociation is large and significant. This is because unpromoted low index planes of Pt, Pt(lll), are relatively inert towards NO dissociation and we adscribe the NO dissociation as the key reaction-initiating step. Such dissociation of diatomic molecules in the field of coadsorbed cations has been discussed in detail by Lang et al [29], The rates of production of CO2. N2 and NjO all depend on... [Pg.520]

Another variation of the preceding method is to apply HPLC to fractionate the cleaned-up aliphatic-aromatic fraction from flash colurim separation of soluble organic matter as it is performed in the Chevron laboratory, for example, as described in Reference 2. A Waters HPLC system equipped with a preparative Whatman Partisil 10 silica column (9.4 X 500 mm), a HPLC pump, and two detectors for separation monitoring (a UV and refractive index detector) are used, giving three fractions of aliphatic hydrocarbons, mono-, di-, and triaromatics and polar compounds. The hrst two fractions are eluted with hexane, whereas polar compounds are eluted with... [Pg.372]

Gel permeation chromatography was performed in tetrahydrofuran using a Waters pump system and a Model 410 differential refractive index detector for the eluant. Five Ultrastyragel columns with nominal porosities ranging from 500 to 105 angstroms were used for all the samples and the polystyrene standards. [Pg.183]

HPLC analysis for succinic acid, succinamic acid, succinamide, succinimide, N-methylsuccinimide, butyric acid, and propionic acid was performed with a Waters Model 515 HPLC pump equipped with a Waters Model 2410 Refractive Index Detector. Separations were performed with an Aminex HPX-87H 300mm column (Bio-Rad Laboratories, Hercules, CA) operated at 35°C, and using 0.005 M H2S04 elluent. [Pg.149]


See other pages where Pumps INDEX is mentioned: [Pg.213]    [Pg.92]    [Pg.93]    [Pg.449]    [Pg.266]    [Pg.439]    [Pg.199]    [Pg.328]    [Pg.78]    [Pg.871]    [Pg.67]    [Pg.135]    [Pg.157]    [Pg.387]    [Pg.414]    [Pg.982]    [Pg.197]    [Pg.426]    [Pg.197]    [Pg.354]    [Pg.344]    [Pg.81]    [Pg.465]    [Pg.498]    [Pg.39]    [Pg.111]    [Pg.253]    [Pg.566]    [Pg.470]    [Pg.785]    [Pg.32]    [Pg.265]    [Pg.55]   