Switch pressure

Automatic filters are made with either viscous-coated or dry filter media. However, the cleaning or disposal of the loaded medium is essentially continuous and automatic. In most such devices the air passes horizontally through a movable filter curtain. As the filter loads with dust, the curtain is continuously or intermittently advanced to expose clean media to the air flow and to clean or dispose of the loaded medium. Movement of the curtain can be provided by a hand crank or a motor drive. Movement of a motor-driven curtain can be actuated automatically by a differential-pressure switch connected across the filter. [Pg.1608]

A complete lubrication console schematic is shown in Fig, 29-87, Instrumentation for the console includes thermometers, pressure switches, and flow meters. [Pg.2540]

An interlock is provided through a centrifugal type of pressure switch (PS) to trip the engine in the case of low lube (lubricating) oil pressure during a run. Since during a. start oil pre.s.sure has not built up, a timer, 7 j is introduced to bypass the trip interlock and avoid a false trip. A relay (contactor), d], is used to provide lube oil pressure interlock. [Pg.507]

Two level pressure switch -1st level contact for alarm... [Pg.641]

A differential pressure switch set to alarm when the pressure drop reaches a predetermined point protects against the loss of oil flow. In addition to the differential pressure switch, a two-way, three-port valve with a pressure gauge is piped in parallel with the differential pressure switch for accurate indication of inlet and outlet oil filter pressure. When a single transflow valve is used with a cooler-filter installation, the differential pressure switch and pressure gauge assembly should span the cooler-filter system. [Pg.551]

A pressure switch located so as to sense falling pressure at the earliest moment should be used to activate the standby pump. The switch should be so connected to the system as to permit testing the startup circuit without shutting down the compressor. Figure 8-8 shows four piping arrangements. The figure at b would be the recommended method. [Pg.313]

Figure 8-8. Pressure gauge and pressure switch piping arrangements [1],... Figure 8-8. Pressure gauge and pressure switch piping arrangements [1],...
Provision must be made in the wiring to maintain power to the standby pump driver. This will prevent power interruption due to the pressure switch contacts opening when lubricant pressure is restored. Cycling of the standby pump will occur if the circuit is not maintained. A reset will have to be furnished to permit shutting down the standby pump when the main pump is back on stream. [Pg.314]

The balance of the controls consists of the required pressure switches and/or transmitters to provide monitoring of the system and alarm and shutdown functions for the critical buffers. Filter differential normally is also monitored and alarmed on high filter differential pressure. [Pg.327]

Many large petrochemical projects involve considerable investment. Plant output value can be measured in staggering amounts of money if value of lost production is calculated. An incorrect pressure switch installed on a compressor may have very little direct financial impact to a compressor manufacturer, but it can cause a loss to the user far in excess of the total value of the compressor package itself. Extra care must therefore be taken in compressor performance tests. In the planning of a pro- ject, testing has to be reviewed to ... [Pg.404]

The pressure switch that permits squeezing of the membranes only when the plate pack is compressed with the hydraulic closing system. [Pg.191]

The same system, but with an on-off pressure switch set to activate the emergency shutdown system if the pressure reaches the predetermined point. The pressure switch remains inactive as long as the pressure is below its trip point. [Pg.14]

In Europe, the gas safety controls must meet the requirements of CEN standards, including flame failure devices, solenoid control valve, pilot con trols, ignition and governor. Overheat-type thermostats and either a pressure switch or an airflow-proving device are fitted to ensure that the burner will cut off in the event of no air flowing through the heater, such as occurs with fan failure. [Pg.714]

For safe operation, the heater should have an overheat thermostat and either a pressure switch or airflow-proving device. This control device ensures that tlie burner will isolate in the event of restricted or no airflow through the heater. [Pg.715]

Automatic roll A roll filter that constantly or intermittently provides a clean portion of filter in the air stream by means of a pressure switch activating an electric motor, which winds the filter from a clean spool to a dirty spool. [Pg.1440]

Rupture discs are also used below relief valves to protect them from corrosion due to ves.sel fluids. The rupture disc bursts first and the relief valve immediately opens. The relief valve reseals, limiting flow when the pressure declines. When this configuration is used, it is necessary to monitor the pressure in the space between the rupture disk and the relief valve, either with a pressure indicator or a high pressure switch. Othei-wise, if a pinhole leak develops in the rupture disk, the pressure would equalize on both sides, and the rupture disk would not rupture at its set pressure because it works on differential pressure. [Pg.367]

It is very important that the inert gas be available from a reliable source and that the proper pressure and flow rate are always provided. A low-pressure switch and alarm are sometimes installed in the inert gas supply line to the equipment and piping. The alarm will warn the operator that a problem may be occurring with the inert gas supply. The switch is also sometimes interlocked to open up a valve in piping from a backup inert gas cylinder bank. [Pg.34]

Various workers have suggested modifications of this useful equipment (26,79). One such modification, which can be adopted to any reactor, is Incorporation of a pressure switch that slops agitation when a predetermined... [Pg.19]

All interlocks checked for correct setting and operation. These will include thermostats, pressurestats, limit switches, pressure switches, process interlocks, etc. ... [Pg.283]

In this form, a continuously running centrifugal pump maintains the pressure. A second pump under the control of a pressure switch is provided to come into operation at a predetermined pressure differential and as an automatic standby to the duty pump. Surplus water is delivered to or taken from a spill tank or cylinder as described previously. [Pg.410]

The determining factor in the frequency of cleaning is the pressure drop. A differential-pressure switch can serve as the actuator in automatic cleaning applications. Cyclone pre-cleaners are sometimes used to reduce the dust load on the filter or to remove large particles before they enter the bag. [Pg.778]

Bellows Nickel bellows can be made by electrodeposition onto a grooved cylinder. In this case, the nickel coating cannot be slid off, and so the substrate must be removed destructively. The grooved cylinders or mandrels are frequently of aluminium alloy which is dissolved away in caustic alkali when the nickel deposition is completed. Uses include pressure switches, flexible couplings, and pressure transducers . [Pg.542]

Air-cooled condensers having two or more fans (Figure 6.2) may have a pressure switch or thermostatic control to stop the fans one by one. This method is simple, cheap, and effective. [Pg.78]

Where a complex system is served by two or more condensers, a complete condenser can be taken offline by a pressure switch. [Pg.79]

Since excess pressure indicates malfunction of part of the system - usually a condenser fault or incorrect closure of a valve - the high-pressure switch should be reset manually, not automatically. [Pg.106]

Abnormally low pressure may not be an unsafe condition and the low-pressure switch may be automatic reset, closing again at a pressure corresponding to a temperature just below that of the load. [Pg.106]

If a plant has been shut down long enough for all pressures to equalize and is then restarted, the suction pressure will pull down below normal until the liquid refrigerant has begun to circulate. Under such circumstances the low-pressure switch may operate. This is a normal occurrence, but may require the addition of a delay timer to prevent frequent starting of the compressor motor. [Pg.106]

A low-pressure switch can also be used in conjunction with a thermostat and a solenoid valve in the pump-down circuit. In this method of control, the thermostat does not stop the compressor but de-energizes the liquid line solenoid valve to stop the supply of refrigerant to the evaporator. The compressor continues to run and pumps down the evaporator until stopped by the low-pressure switch. When the thermostat again calls for cooling, it opens the solenoid valve, liquid enters the evaporator and the low-pressure switch will close again to restart the compressor. This method is used to ensure that the evaporator is kept clear of liquid when the plant is off. If there is any leak at the solenoid valve, it will cause the... [Pg.106]


See other pages where Switch pressure is mentioned: [Pg.476]    [Pg.379]    [Pg.1601]    [Pg.458]    [Pg.84]    [Pg.85]    [Pg.124]    [Pg.346]    [Pg.323]    [Pg.78]    [Pg.359]    [Pg.524]    [Pg.53]    [Pg.76]    [Pg.77]    [Pg.423]    [Pg.444]    [Pg.285]    [Pg.561]    [Pg.631]    [Pg.631]    [Pg.105]    [Pg.106]   
See also in sourсe #XX -- [ Pg.172 ]

See also in sourсe #XX -- [ Pg.501 ]




SEARCH



Absolute pressure switches

Differential pressure-actuated switches

Piston type pressure switches

Pressure measurement switches)

Pressure switch characteristics

Pressure switches sensor

Pressure water level switches

Response of flow to valve opening when the differential pressure controller is switched out

Switches proof pressure