Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Press Routines

For best results, a method that allows real-time measurement and control of the pressing process is preferred and is available on today s commercial presses.There are four commonly used pressing routines, but only three take advantage of force-sensing, distance-sensing, or real-time feedback control of the connector press. Connector complexity and equipment availability dictate press-fit assembly methodology. [Pg.1154]

Although this type of pressing is discouraged, it may be adequate for low lead-count, coarse-pitch connectors in noncritical assemblies. As with any press routine, a suitable support fixture must be used beneath the board to keep the assembly from breaking or flexing. It should incorporate support to counter the forces of the ram, and relieved areas to accept protrusion of press-pins below the bottom side of the board and clearances for bottomside components as shown in Fig. 49.11. [Pg.1154]

The principle application of XRF thin-film analysis is in the simultaneous determination of composition and thickness. The technique has been used for the routine analysis of single-layer films since 1977 and multiple-layer films since 1986. Two main sources of publications in the fields are the annual volumes of Advances in X-Ray Analysis by Plenum Press, New York, and the Journal of X-Ray Spectrometry by Heyden and Sons, London. Typical examples on the analysis of single-layer films and multiple-layer films are used to illustrate the capabilities of the technique. [Pg.343]

The direct transmission experiment is the most elegant and yields the most quantifiable results. The beam makes a single pass through the sample before reaching the detector. The bands of interest in the absorbance spectrum should have peak absorbances in the range of 0.1—2.0 for routine work, although much weaker or stronger bands can be studied. Various holders, pellet presses, and liquid cells have been... [Pg.422]

In addition to new bars, lounges and restaurants, parties and press events routinely served specially created cocktails, and cocktail conception specialists like Jerri Banks, Francesco Lafranconi and Dushan Zaric and Jason Kosmas of Cocktail Conceptions are now an established part of the liquor industry. [Pg.3]

Most of the algorithms and formulae discussed in this chapter can be implemented as expressions in computer spreadsheets, and the rest as simple computer programs. Most are also incorporated into the Microsoft Excel spreadsheet program by the Isoplot add-in (Ludwig 1999, in press) as user-available functions and graphical routines (Appendix III). [Pg.651]

It is noted that Press et al. (1992) give a subroutine that implements the simplex method of Nelder and Mead. They also recommend to restart the minimization routine at a point where it claims to have found a minimum... [Pg.82]

Bremser produced tables of these HOSE codes from NMR work that was carried out at BASF in Germany. Most modern carbon prediction routines still use this HOSE code today (albeit slightly modified from the original). Modem software hides all the HOSE code generation in the background so all you do is draw a structure and press the predict button and all the chemical shifts are calculated. [Pg.169]

Laser ablation ICP-MS (LA-ICP-MS) was established in the early 1990s as a potential routine tool for the measurement of trace and ultra-trace elements in silicate systems for geology. Early studies (Perkins et al. 1993) used sample preparation techniques identical to that used to prepare rock samples for WDXRF, i.e., either a pressed powder disk or a glass bead fusion method (see Appendix VIII). Such studies concluded that LA-ICP-MS had the potential to surpass XRF in terms of the limits of detection achieved and INAA in terms of the speed of analysis (Perkins et al. 1993 481). It has long been recognized that the main limit on the quantitative performance of LA-ICP-MS is the homogeneity at the trace and ultra-trace level of the solid calibration standards available. Subsequent work (e.g., Hollecher and Ruiz 1995, Norman et al. 1996) has demonstrated that some of the international... [Pg.135]

Plate-and-frame filter presses are particularly suited to batch operations. Modern frames are made of polymers (mainly polypropylene), which have replaced wood as a building material. Large amounts of products, on the other hand, are filtered routinely via continuous-belt filters or rotary drum-type filters. Following the filtration step, inorganic salts are removed by washing with water. [Pg.203]

Dumas was the first chemist to give a practical laboratory course as a routine part of instruction to students, beginning in 1832 at the Ecole Polytechnique. See Leo J. Klosterman, "A Research School of Chemistry." On the earlier period, see Maurice Crosland, The Society of Arcueil A View of French Science at the Time of Napoleon I (Cambridge, Harvard University Press, 1967) and Crosland, Gay-Lussac. [Pg.70]

These sorts of analyses are limited only by the ability of the chosen mass spectrometer to detect the test-compound under infusion-buffer conditions. In many cases, there will not be a problem even at low nanomolar compound concentrations, but in others MS will be hard-pressed to detect compounds even at micromolar concentrations. The online FAC-MS system will always be challenged by the inherent incompatibility of routine assay buffers with MS, but there are opportunities to reconfigure either the ion source or the buffer composition for... [Pg.225]

In order to determine how useful the Presster would be in predicting the behavior of a formulation on a production tablet press, it was decided to do a retrospective evaluation of two products that are routinely manufactured in production. The conditions used for manufacturing the two products in production were simulated on the Presster and the results are presented in Figures 3 and 4. [Pg.380]

Type of Service. The type of service—quality assurance, methods development, or routine testing—for each instrument or laboratory is a general consideration, as is the question of whether several types of service will be required of the system. A quality assurance laboratory associated with a chemicals production facility has far simpler needs in terms of analytical capability than a methods development laboratory or one that normally analyzes biological samples for pharmacologically active compounds at sub-ppm or even ppb concentrations. On the other hand, the data storage and reduction needs of a quality assurance laboratory are usually much more pressing than those of a methods development laboratory. [Pg.430]


See other pages where Press Routines is mentioned: [Pg.612]    [Pg.612]    [Pg.1154]    [Pg.612]    [Pg.612]    [Pg.1154]    [Pg.645]    [Pg.350]    [Pg.1504]    [Pg.1709]    [Pg.100]    [Pg.560]    [Pg.39]    [Pg.327]    [Pg.475]    [Pg.440]    [Pg.42]    [Pg.335]    [Pg.51]    [Pg.446]    [Pg.424]    [Pg.12]    [Pg.49]    [Pg.44]    [Pg.270]    [Pg.46]    [Pg.5]    [Pg.118]    [Pg.362]    [Pg.72]    [Pg.76]    [Pg.430]    [Pg.372]    [Pg.404]    [Pg.8]    [Pg.166]    [Pg.138]    [Pg.46]   


SEARCH



Routine

© 2024 chempedia.info