Precision quality control

Quality control procedures are generally established to provide checks on the data that have been collected to evaluate whether in fact the quality assurance procedures were followed and whether the data meet agreed-upon norms. Otherwise, it is difficult for the user to judge the integrity of a data set per se, because there may be few ways to tell that procedures were not followed or values properly recorded. Quality control measures can be linked to the quality assurance procedures. In the example given above for use of field blanks, spikes and duplicate samples, laboratories must provide evidence that their analysis of these samples meets acceptable statistical guidelines for accuracy and precision. Quality control can also simply involve careful analysis of a data set to determine whether it is internally consistent. [Pg.152]

At-line At-line is the fully automated analysis in a laboratory. The sample is still taken manually or by stand-alone devices. The sample is transported to the laboratory, e.g., by pneumatic delivery. Several hundred samples can be measured per day, allowing for precise quality control of slow processes. At-line laser diffraction is widely used for quality control in the cement industry. See Fig. 21-22. [Pg.2261]

Quality control procedures are the mechanisms established to control errors and make analyses more accurate and precise. Quality control procedures help you... [Pg.32]

A final component of a quality control program is the certification of an analyst s competence to perform the analysis for which he or she is responsible. Before an analyst is allowed to perform a new analytical method, he or she may be required to successfully analyze an independent check sample with acceptable accuracy and precision. The check sample should be similar in composition to samples that the analyst will routinely encounter, with a concentration that is 5 to 50 times that of the method s detection limit. [Pg.708]

The method was validated in accordance to the guidelines of the international conference on harmonization (ICH). Data with respect to accuracy, within- and between run precision, recovery, detection and quantitation limits were reported and found to be within the accepted international criteria. Neither endogeneous substances nor the commonly used dmgs were found to interfere with the retention times of the analytes. Standard solutions of the dmg and quality control preparations at high and low level concentrations were demonstrated to be stable at room temperature and/or -20°C for long and short periods of time. [Pg.395]

Quality assurance programs are designed to serve two functions (1) assessment of collected air quality data and (2) improvement of the data collection process. These two functions form a loop as air quality data are collected, procedures are implemented to determine whether the data are of acceptable precision and accuracy. If they are not, increased quality control procedures are implemented to improve the data collection process. [Pg.223]

In conclusion it must be emphasised again that all the tests used are accelerated tests and only provide information on susceptibility to intergranular attack under the precise test conditions prevailing. They are quality control tests that may be used to demonstrate either that heat treatment has been carried out adequately or that a steel will withstand the test for a certain sensitising heat treatment. [Pg.1039]

Adequate process control and its associated instrumentation are essential to have product quality control. In some cases the goal is precise adherence to a control point. In others it is simply to maintain the temperature within a comparatively narrow range. [Pg.170]

Adequate PC and its associated instrumentation are essential for product quality control. The goal in some cases is precise adherence to a single control point. In other cases, maintaining the temperature within a comparatively small range is all that is necessary. For effortless controller tuning and the lowest initial cost, the processor should select the simplest controller (of temperature, time, pressure, melt-flow, rate, etc.) that will produce the desired results. [Pg.531]

Several analytical methods are available to quantify chlorophylls and choice depends on the information needed. For quality control in industries and legislation attendance, simple and cost-effective methods represent widely used problem-solving approaches. For research purposes, more sensitive and precise methods are necessary to identify chlorophylls and derivatives simultaneously and individually. [Pg.434]

The establishment of performance criteria for a given tumor marker test is not a simple process because accuracy and precision are unique for each type of analyte and its application. Establishing methodological limits for accuracy, precision, sensitivity, and specificity often requires standard reference materials, quality control materials, comparative studies, and actual clinical specimens. Accuracy and precision must be measured over the analyte reportable range for which the device is intended to be used. Sensitivity and specificity must be considered with respect to the intended clinical use of the device. Also, the indications for use should be carefully considered in the design of the study protocol. The indications for class II should be to monitor residual tumor after surgery (or radiation), the recurrence of tumor, or response to therapy. A 510(k) must provide clear evidence that the device is accurate, safe, effective, and substantially equivalent to a device legally marketed in the United States. [Pg.176]

The identification of sampling requirements involves specifying the sampling design, the sampling method, sample numbers, types, and locations, and the level of sampling quality control. Data quality requirements include precision, accuracy, representativeness, completeness, and comparability. [Pg.598]

With respect to method application, once validation has been satisfactorily completed, there is little question that use of the analytical method in worker safety and re-entry studies falls under the full requirements of the GLP Standards. In addition, there should be an adequate level of quality control measurements taken in conjunction with the specimens so as to provide for a meaningful assessment of accuracy and precision, as well as verification of freedom from artifactual interferences. Along with these measurements there needs to be reasonably rigid data acceptance criteria in place (usually established during validation) which are consistently applied during the course of the specimen analytical phase of the study. [Pg.159]

The principles of quality assurance are commonly related to product and process control in manufacturing. Today the field of application greatly expanded to include environmental protection and quality control within analytical chemistry itself, i.e., the quality assurance of analytical measurements. In any field, features of quality cannot be reproduced with any absolute degree of precision but only within certain limits of tolerance. These depend on the uncertainties of both the process under control and the test procedure and additionally from the expense of testing and controlling that may be economically justifiable. [Pg.116]

Method performance study All laboratories follow the same written protocol and use the same test method to measure a quantity (usually concentration of an analyte) in sets of identical test samples. The results are used to estimate the performance characteristics of the method, which are usually within-laboratory- and between-laboratory precision and - if relevant - additional parameters such as sensitivity, limit of detection, recovery, and internal quality control parameters (IUPAC Orange Book [1997, 2000]). [Pg.252]

If repeatability is the only estimate of precision that is obtained, this is unlikely to be representative of the variability observed when the method is used over a long period of time. Intermediate precision is often more relevant - this expresses the within-laboratory variation or within-laboratory reproducibility (different days, different analysts, different equipment, etc.). This is initially obtained from validation studies and confirmed later by examining the results obtained for quality control material measured over a period of about three months (see the quality control (QC) charts in Chapter 6). [Pg.58]

GFAAS end analysis of Pb in blood was critically discussed in a review, including methods of introducing the sample into the furnace, matrix interferences and ways of improving the precision of the method, such as use of a stabilized temperature platform40. An evaluation program was carried out for quality control materials and proficiency for... [Pg.434]

Precision and Accuracy of Quality Control Samples for Automated LLE of Omeprazole and 5-OH Omeprazole Metabolite... [Pg.32]


See other pages where Precision quality control is mentioned: [Pg.16]    [Pg.315]    [Pg.283]    [Pg.4030]    [Pg.33]    [Pg.16]    [Pg.315]    [Pg.283]    [Pg.4030]    [Pg.33]    [Pg.2938]    [Pg.48]    [Pg.50]    [Pg.393]    [Pg.31]    [Pg.362]    [Pg.279]    [Pg.448]    [Pg.156]    [Pg.92]    [Pg.7]    [Pg.606]    [Pg.51]    [Pg.31]    [Pg.51]    [Pg.56]    [Pg.28]    [Pg.471]    [Pg.9]    [Pg.35]    [Pg.704]    [Pg.754]    [Pg.125]    [Pg.109]    [Pg.435]    [Pg.435]   