Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Power plants installation

Figure 4.11 Power plant installation where multiple tower arrangement is utilized (towers ate operated in parallel). Cooling towers are placed in a row at right angles to the prevailing winds (courtesy of The Marley Company, Mission, KS). Figure 4.11 Power plant installation where multiple tower arrangement is utilized (towers ate operated in parallel). Cooling towers are placed in a row at right angles to the prevailing winds (courtesy of The Marley Company, Mission, KS).
Following testing at UTCFC, the power plant was delivered to DOE s Argonne National Laboratory. Figure 4 shows the power plant installed in the ANL test facility. Testing at ANL included steady-state and transient operation and provided experience in the new test facility. [Pg.269]

Figure 4. 50 kW power plant installed in ANL test facility... [Pg.269]

Zonal Inspection A collective term comprising selected general visual inspeetions and visual checks that are applied to each aeroplane zone, defined by access and area, to check system and power plant installations and structure for security and general condition. Refer to 03-02-13007-02 for further definition. [Pg.402]

In recent years, carbonate fuel cell technology has enjoyed a steady improvement both in cost reduction and performance. Large-scale manufacturing combined with a multitude of power plant installations has resulted in the establishment of the carbonate fuel cell technology as a leading candidate for efficient and reliable distributed generation. [Pg.217]

After preliminary shop tests on different mockups (e.g. superheater and reheater headers and steamline pipe sections), since 1996 AEBIL systems have been installed and are at work on several power plant components. In particular, three different components have been monitored throughout 1997 (monitoring still under way at the time being) ... [Pg.70]

The specific results of well over 1 year of continued monitoring will be discussed in a second paper. It is pointed out here that the AEBIL monitoring system installed in the power plant for the above monitoring purposes has efficiently and continuedly performed during this time interval, with no instrumentation reliability problems. [Pg.71]

The configuration of the AEBIL system, installed in an ENEL power plant can be summarized as follows ... [Pg.77]

The pipelines wear and increase of their total length, complex natural-technical and social terms of operation of the most hazardous objects e g., nuclear and heating power plants, chemical and microbiological enterprises, air-space systems, hydro-technical installations, all types of traffic, etc. — here are the reasons of urgent necessity to use as much as possible the NDT and TD systems. [Pg.910]

An example of a modem, tangentially fired, supercritical, lignite-fuel furnace is shown in Figure 5. This unit, at maximum continuous ratings, supplies 2450 metric tons pet hour superheat steam at 26.6 MPa (3850 psi) and 544°C, and 2160 t/h reheat steam at 5.32 MPa (772 psi) and 541°C. These ate the values at the superheater and reheater oudet, respectively. Supercritical fluid-pressure installations ate, however, only rarely needed. Most power plants operate at subcritical pressures in the range of 12.4—19.3 MPa (1800—2800 psi). [Pg.143]

In addition, other utiUties are installing estabUshed solar cells in a growing number of tests that may lead to a mass market. The studies may indicate the extent to which solar cells can be used to avoid installation costs for new distribution lines between conventional power plants and remote customers buildings. Also, among other objectives, PV cells may provide an economical means of helping to supply demand during peak summer periods in northern climates. [Pg.105]

Three demonstrations of the LIMB technology have been carried out. The first was a privately funded project in the 75 MWt Boiler 405 at the No. 4 AC Station of Inland Steel Industries, Inc. (56). By injecting 70 wt % minus 200 mesh (74 -lm) limestone, approximately 40% SO2 removal was achieved at a Ca S ratio of 3. This rose to 50% removal when the Ca S ratio was increased to 4. The second LIMB demonstration was the backup desulfurization system installed by B W as part of the relocation, repowering, and reconfiguration of the PCS power plant (46). [Pg.261]

Industrial use of cogeneration leads to small, dispersed electric-power-generation installations—an alternative to complete reliance on large central power plants. Because of the relatively snort distances over which thermal energy can be transported, process-heat generation is characteristically an on-site process, with or without cogeneration. [Pg.2405]

Our present discussions relate only to the laboratory testing of safety-related secondary systems, as are employed in critical areas such as areas of emergency power supply and reactor power control supply etc. of a nuclear power plant (NPP) according to IEEE 344 and lEC 60980. There are other codes also but IEEE 344 is referred to more commonly. Basically, all such codes are meant for an NPP but they can be applied to other critical applications or installations that are prone to earthquakes. [Pg.436]

After the final designs are complete it is recommended that the actual touch (actual) and step voltage (actual) are rechecked for both power plant and switchyard areas separately, to ensure that they are within the tolerable limits as determined above. After the ground stations have been finally installed the actual step and touch voltages must be measured to verify the designs. [Pg.716]

San Diego Gas Electric s expander is installed in parallel to a major city gate station. This type of system could be installed on a pressure reducing station supplying natural gas to an electric power plant. Large regulator stations serving industrial customers are another possible application. [Pg.471]


See other pages where Power plants installation is mentioned: [Pg.1195]    [Pg.66]    [Pg.155]    [Pg.159]    [Pg.232]    [Pg.377]    [Pg.81]    [Pg.110]    [Pg.547]    [Pg.443]    [Pg.218]    [Pg.1195]    [Pg.66]    [Pg.155]    [Pg.159]    [Pg.232]    [Pg.377]    [Pg.81]    [Pg.110]    [Pg.547]    [Pg.443]    [Pg.218]    [Pg.76]    [Pg.402]    [Pg.582]    [Pg.582]    [Pg.48]    [Pg.267]    [Pg.234]    [Pg.239]    [Pg.474]    [Pg.1]    [Pg.14]    [Pg.14]    [Pg.88]    [Pg.104]    [Pg.464]    [Pg.1613]    [Pg.2525]    [Pg.444]    [Pg.449]    [Pg.765]    [Pg.929]    [Pg.426]    [Pg.5]   
See also in sourсe #XX -- [ Pg.68 ]




SEARCH



Plant installation

Power plants

© 2024 chempedia.info