Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Polymer coating method

Chemisorption requires direct contact between the chemisorbed molecule and the electrode surface as a result, the highest coverage achievable is usually a monomolecular layer. This may be contrasted with several of the methods to be discussed later that allow the electrode surface to be covered with thick films (i.e., multimolecular layers) of the desired molecule. In addition to this coverage limitation, chemisorption is rarely completely irreversible. In most cases, the chemisorbed molecules slowly leach into the contacting solution phase during electrochemical or other investigations of the chemisorbed layer. For these reasons, electrode modification via chemisorption was quickly supplanted by other methods, most notably polymer-coating methods. [Pg.405]

The control of electron transfer is a critical issue in the fabrication of molecular electronic devices from the viewpoint of electronic circuit formation however, electron transfer processes of redox polymer-coated electrodes fabricated using a conventional polymer-coating method usually shows a diffusion-like behavior because the redox sites are randomly distributed in the polymer film (Fig. la) 17-20 consequently, it is difficult to control the electron transfer direction in three dimensions. [Pg.389]

Extmsion technology is used to produce spunbond, meltblown, and porous-film nonwovens. Fabrics produced by these systems are referred to individually as spunbonded, meltblown, and textured- or apertured-film nonwovens, or genericaHy as polymer-laid nonwovens. These fabrics are produced with machinery associated with such polymer extmsion methods as melt-spinning, film casting, and extmsion coating. In polymer-laid systems, fiber stmctures are simultaneously formed and manipulated. [Pg.146]

There are several methods of buffer and capillary surface modification used to prevent electrostatic interactions. Two modes have been examined mn buffer with pH >10 in the uncoated capillary and anionic polymer coating capillary, developed in lAI. [Pg.100]

Adhesion of polymer coatings (thickness 60-70 fik) formed on the glass surface is obtained by lattice notch" method. [Pg.273]

Another method to synthesize hollow nanocapsules involves the use of nanoparticle templates as the core, growing a shell around them, then subsequently removing the core by dissolution [30-32]. Although this approach is reminiscent of the sacrificial core method, the nanoparticles are first trapped and aligned in membrane pores by vacuum filtration rather than coated while in aqueous solution. The nanoparticles are employed as templates for polymer nucleation and growth Polymerization of a conducting polymer around the nanoparticles results in polymer-coated particles and, following dissolution of the core particles, hollow polymer nanocapsules are obtained. [Pg.516]

FAB-MS has been used for the analysis of lubricant additives, thermally labile or involatile organic compounds, such as macromolecules and dyes, and inorganic compounds. Cationic dyes and dye intermediates, which are typically acid salts, readily yield preformed ions in the FAB matrix solution. They are also very difficult to address by other MS ionisation methods due to their involatility. Lay and Chang [85] used positive ion FAB to characterise a mixture of amine and ketimine cross-linking agents for polymer coatings. Bentz et al. [Pg.370]

Special electrochemical sensors that operate on the principle of the voltammetric cell have been developed. The area of chemically modified solid electrodes (CMSEs) is a rapidly growing field, giving rise to the development of new electroanalytical methods with increased selectivity and sensitivity for the determination of a wide variety of analytes [490]. CMSEs are typically used to preconcentrate the electroactive target analyte(s) from the solution. The use of polymer coatings showing electrocatalytic activity to modify electrode surfaces constitutes an interesting approach to fabricate sensing surfaces useful for analytical purposes [491]. [Pg.670]

In order to act as a transducer optode must be attached to the optical fiber. Bulks (>1 mm) of sol-gel matrix can be easily glued to the fiber tip, especially, if the polymer fiber is used39. The smaller optodes can be attached to fiber end by dip-coating method or simply by direct painting of the fiber-tip with a liquid gel. [Pg.361]

To prepare ultrathin polymer films on the surface of wafers, especially those of large diameter (6 or 8 inch), uniformity and defect density become important factors in determining the resist quality. The conventional spin coating method has been reported to introduce interference striations (11) and high defect densities (2.31 when used to prepare ultrathin polymer films. As an alternative approach, the LB technique has been proposed as being suited to the preparation of more uniform ultrathin polymer films (2). Using this technique monolayer polymer films can be transferred layer by layer to the surface of a solid substrate from the water surface. An important feature of the LB technique is that the accumulation of monolayer films allows the thickness of the built-up film to be controlled in a precise manner. Consequently, extremely uniform and ultrathin polymer films can be prepared. [Pg.350]

The efficacy of CE separation depends considerably on the type of capillary. Fused-silica capillaries without pretreatment are used most frequently. Its outside is coated with a polymer layer to make it flexible and to lessen the occurrence of breakage. The polymer coating has to be dissolved with acid or burned away at the detection point. Capillaries with an optically transparent outer coating have also found application in CE. The objectives of the development of chemically modified capillary walls were the elimination of electro-osmotic flow and the prevention of adsorption on the inner wall of the capillary. Another method to prevent the adsorption of cationic analyses and proteins is the use of mobile phase additives. The modification of the pH of the buffer, the addition of salts, amines and polymers have all been successfully employed for the improvement of separation. [Pg.54]


See other pages where Polymer coating method is mentioned: [Pg.743]    [Pg.6319]    [Pg.216]    [Pg.216]    [Pg.217]    [Pg.79]    [Pg.216]    [Pg.216]    [Pg.217]    [Pg.147]    [Pg.743]    [Pg.6319]    [Pg.216]    [Pg.216]    [Pg.217]    [Pg.79]    [Pg.216]    [Pg.216]    [Pg.217]    [Pg.147]    [Pg.171]    [Pg.213]    [Pg.328]    [Pg.135]    [Pg.149]    [Pg.162]    [Pg.52]    [Pg.60]    [Pg.364]    [Pg.88]    [Pg.506]    [Pg.687]    [Pg.696]    [Pg.296]    [Pg.261]    [Pg.72]    [Pg.262]    [Pg.131]    [Pg.261]    [Pg.420]    [Pg.53]    [Pg.12]    [Pg.471]    [Pg.284]    [Pg.285]    [Pg.289]   


SEARCH



Coating methods

Electroactive polymers conductive coating methods

Methods Applied to Polymer Layers Coated on Electrodes

Polymer coating method advantages

Polymer coating method approach

Polymer coating method character

Polymer coating method contamination

Polymer coating method polystyrene surfaces

Polymer coating method triblock copolymer

Polymer coatings

Polymer method

© 2024 chempedia.info