Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Poly samples

Solid-phase microextractions also have been developed. In one approach, a fused silica fiber is placed inside a syringe needle. The fiber, which is coated with a thin organic film, such as poly(dimethyl siloxane), is lowered into the sample by depressing a plunger and exposed to the sample for a predetermined time. The fiber is then withdrawn into the needle and transferred to a gas chromatograph for analysis. [Pg.213]

This experiment describes a simple gravimetric procedure for determining the %w/w Cl in samples of poly(vinyl chloride). [Pg.266]

When a 0.8006-g sample of a poly(styrene/maleic anhydride) copolymer was prepared in the same manner, the following results were obtained... [Pg.453]

At 25°C, the Mark-Houwink exponent for poly(methyl methacrylate) has the value 0.69 in acetone and 0.83 in chloroform. Calculate (retaining more significant figures than strictly warranted) the value of that would be obtained for a sample with the following molecular weight distribution if the sample were studied by viscometry in each of these solvents ... [Pg.69]

Plazek et al.t measured the viscosities of a poly(dimethyl siloxane) sample of = 4.1 X 10 over a range of temperatures using the falling-ball method. Stainless steel (P2 = 7.81 g cm" ) balls of two different diameters,... [Pg.131]

As we did in the case of relaxation, we now compare the behavior predicted by the Voigt model—and, for that matter, the Maxwell model—with the behavior of actual polymer samples in a creep experiment. Figure 3.12 shows plots of such experiments for two polymers. The graph is on log-log coordinates and should therefore be compared with Fig. 3.11b. The polymers are polystyrene of molecular weight 6.0 X 10 at a reduced temperature of 100°C and cis-poly-isoprene of molecular weight 6.2 X 10 at a reduced temperature of -30°C. [Pg.170]

Figure 7.10 Nuclear magnetic resonance spectra of three poly(methyl methacrylate samples. Curves are labeled according to the preominant tacticity of samples. [From D. W. McCall and W. P. Slichter, in Newer Methods of Polymer Characterization, B. Ke (Ed.), Interscience, New York, 1964, used with permission.]... Figure 7.10 Nuclear magnetic resonance spectra of three poly(methyl methacrylate samples. Curves are labeled according to the preominant tacticity of samples. [From D. W. McCall and W. P. Slichter, in Newer Methods of Polymer Characterization, B. Ke (Ed.), Interscience, New York, 1964, used with permission.]...
The phenomena we discuss, phase separation and osmotic pressure, are developed with particular attention to their applications in polymer characterization. Phase separation can be used to fractionate poly disperse polymer specimens into samples in which the molecular weight distribution is more narrow. Osmostic pressure experiments can be used to provide absolute values for the number average molecular weight of a polymer. Alternative methods for both fractionation and molecular weight determination exist, but the methods discussed in this chapter occupy a place of prominence among the alternatives, both historically and in contemporary practice. [Pg.505]

Table 9.3 lists the intrinsic viscosity for a number of poly(caprolactam) samples of different molecular weight. The M values listed are number average figures based on both end group analysis and osmotic pressure experiments. Tlie values of [r ] were measured in w-cresol at 25°C. In the following example we consider the evaluation of the Mark-Houwink coefficients from these data. [Pg.605]

Table 9.3 Intrinsic Viscosity as a Function of Molecular Weight for Samples of Poly(caprolactam) ... Table 9.3 Intrinsic Viscosity as a Function of Molecular Weight for Samples of Poly(caprolactam) ...
Poly(7-benzyl-L-glutamate) is known to possess a helical structure in certain solvents. As part of an investigationf of this molecule, a fractionated sample was examined in chloroform (CHCI3) and chloroform saturated ( 0.5%) with dimethyl formamide (DMF). The following results were obtained ... [Pg.708]

Bhatnagar and Biswast measured the turbidity at 436 nm of 2l single sample of poly(methyl methacrylate) in several solvents, including acetone and methyl ethyl ketone (MEK) ... [Pg.717]

Molybdenum trioxide is a condensed-phase flame retardant (26). Its decomposition products ate nonvolatile and tend to increase chat yields. Two parts of molybdic oxide added to flexible poly(vinyl chloride) that contains 30 parts of plasticizer have been shown to increase the chat yield from 9.9 to 23.5%. Ninety percent of the molybdenum was recovered from the chat after the sample was burned. A reaction between the flame retardant and the chlorine to form M0O2 012 H20, a nonvolatile compound, was assumed. This compound was assumed to promote chat formation (26,27). [Pg.458]

Analysis for Poly(Ethylene Oxide). Another special analytical method takes advantage of the fact that poly(ethylene oxide) forms a water-insoluble association compound with poly(acryhc acid). This reaction can be used in the analysis of the concentration of poly(ethylene oxide) in a dilute aqueous solution. Ereshly prepared poly(acryhc acid) is added to a solution of unknown poly(ethylene oxide) concentration. A precipitate forms, and its concentration can be measured turbidimetricaHy. Using appropriate caUbration standards, the precipitate concentration can then be converted to concentration of poly(ethylene oxide). The optimum resin concentration in the unknown sample is 0.2—0.4 ppm. Therefore, it is necessary to dilute more concentrated solutions to this range before analysis (97). Low concentrations of poly(ethylene oxide) in water may also be determined by viscometry (98) or by complexation with KI and then titration with Na2S202 (99). [Pg.343]

Bayer marketed PPS compounds in the United States under the trade name Tedur, but the company has exited the PPS business. PPS is also marketed in the United States by GE Plastics, whose source of neat resin is Tosoh Corporation of Japan. GE Plastics markets PPS under the trade name Supec PPS. Patent activity by Tennessee Eastman describes an alternative process for the production of poly(phenylene sulfide/disulfide), although samples of such product have not appeared as of early 1996. Both Phillips and Hoechst Celanese have aimounced plans to debotdeneck their existing U.S. faciUties in order to meet anticipated market growth. [Pg.442]

The actual time required for poly-L-lactide implants to be completely absorbed is relatively long, and depends on polymer purity, processing conditions, implant site, and physical dimensions of the implant. For instance, 50—90 mg samples of radiolabeled poly-DL-lactide implanted in the abdominal walls of rats had an absorption time of 1.5 years with metaboHsm resulting primarily from respiratory excretion (24). In contrast, pure poly-L-lactide bone plates attached to sheep femora showed mechanical deterioration, but Httie evidence of significant mass loss even after four years (25). [Pg.190]

The crystallinity of poly(lactide- (9-glycoHde) samples has been studied (36). These copolymers are amorphous between the compositional range of 25—70 mol % glycoHde. Pure polyglycoHde was found to be about 50% crystalline whereas pure poly-L-lactide was about 37% crystalline. An amorphous poly(L-lactide-i (9-glycoHde) copolymer is used in surgical cHps and staples (37). The preferred composition chosen for manufacture of cHps and staples is the 70/30 L-lactide/glycoHde copolymer. [Pg.191]

An example is poly(bis(p-carboxyphenoxy)propane) (PCPP) which has been prepared as a copolymer with various levels of sebacic anhydride (SA). Injection molded samples of poly (anhydride) / dmg mixtures display 2ero-order kinetics in both polymer erosion and dmg release. Degradation of these polymers simply releases the dicarboxyhc acid monomers (54). Preliminary toxicological evaluations showed that the polymers and degradation products had acceptable biocompatibiUty and did not exhibit cytotoxicity or mutagenicity (55). [Pg.192]

There are numerous misconceptions about the sources of various chemical elements in waste, particularly those that are potential acid formers when the waste is incinerated or mechanically converted and used as a refuse-derived fuel. For example, it is often mistakenly stated that the source of chlorine in waste, hence a potential source of HCl emissions, is poly(vinyl chloride). The relative contents of selected, potentially acid-forming elements in the organic portion of a sample of waste collected from various households in one U.S. East Coast city is given in Table 2 (17). In this city, a chief source of chlorine in the waste is NaCl, probably from food waste. [Pg.543]


See other pages where Poly samples is mentioned: [Pg.214]    [Pg.214]    [Pg.65]    [Pg.80]    [Pg.114]    [Pg.114]    [Pg.130]    [Pg.130]    [Pg.416]    [Pg.537]    [Pg.640]    [Pg.163]    [Pg.171]    [Pg.546]    [Pg.548]    [Pg.42]    [Pg.430]    [Pg.148]    [Pg.149]    [Pg.221]    [Pg.303]    [Pg.354]    [Pg.360]    [Pg.399]    [Pg.411]    [Pg.378]    [Pg.437]    [Pg.480]    [Pg.527]    [Pg.34]    [Pg.49]    [Pg.94]   
See also in sourсe #XX -- [ Pg.373 ]




SEARCH



Poly , blend sample with

Poly PDMS sample

Poly crystalline sample

Poly sample, well-crystallized

Preparation, sample, poly

© 2024 chempedia.info