Performance continuous monitoring

Data Acquisition and Control System. Computer-based system that controls all parameters of HPLC instrument (eluent composition (mixing of different solvents) temperature, injection sequence, etc.) and acquires data from the detector and monitors system performance (continuous monitoring of the mobile-phase composition, temperature, backpressure, etc.). [Pg.10]

Biosensors can be defined as chemical sensor systems in which an analyte is detected based on biochemical processes or biochemical utilization. A biosensor is mostly composed of a biological element responsible for sampling and tracing, and a physical element called a transducer responsible for sample transmission and further processing (see also Part V, Chapters 8 and 9). The term biosensor does not really meet the lUPAC definition, in which sensors are defined to be self-containing, perform continuous monitoring and are reversible. For the purpose of this chapter, the term biosensor will not be so strictly used as in the traditional context. [Pg.1544]

Computerized goniometer with digital sensing and electronics can either perform continuous monitoring or calculate individual ROM/EOM from a compound motion function (see Figure 76.2c)... [Pg.1248]

Sensors on the tree allow the control module to transmit data such as tubing head pressure, tubing head temperature, annulus pressure and production choke setting. Data from the downhole gauge is also received by the control module. With current subsea systems more and more data is being recorded and transmitted to the host facility. This allows operations staff to continuously monitor the performance of the subsea system. [Pg.271]

The specific results of well over 1 year of continued monitoring will be discussed in a second paper. It is pointed out here that the AEBIL monitoring system installed in the power plant for the above monitoring purposes has efficiently and continuedly performed during this time interval, with no instrumentation reliability problems. [Pg.71]

Automated analyzers may be used for continuous monitoring of ambient poUutants and EPA has developed continuous procedures (23) as alternatives to the referenced methods. Eor source sampling, EPA has specified extractive sampling trains and analytical methods for poUutants such as SO2 and SO [7446-11-9] sulfuric acid [7664-93-9] mists, NO, mercury [7439-97-6], beryUium [7440-41-7], vinyl chloride, and VOCs (volatile organic compounds). Some EPA New Source Performance Standards requite continuous monitors on specified sources. [Pg.384]

There are important economic consequences of a process being out of control for example, product waste and customer dissatisfaction. Hence, statistical process control does provide a way to continuously monitor process performance and improve product quahty. A typic process may go out of control due to several reasons, including... [Pg.735]

All scales reqmre continuous monitoring to assure that the desired set weight is maintained and does not drift off because of changes in product bulk-density or flow characteristics. Microprocessors can perform this task automatically. [Pg.1943]

The safe operation of a chemical process requires continuous monitoring of the operation to stabilize the system, prevent deviations, and optimize system performance. This can be accomplished through the use of instrumentation/control systems, and through human intervention. The human element is discussed in Chapter 6. Proper operation requires a close interaction between the operators and the instrumentation/control system. To a large extent, batch operations have simple control systems and are frequently operated in the manual mode. The instrumentation system is the main source of information about the state of the process. Some of the typical functions of the instrumentation/control system are... [Pg.109]

The evaluation methods could be direct, e.g., measuring a containment index, or indirect, e.g., measuring pressure loss or velocity distribution. The direct methods are used to measure the performance of a hood or an inlet during periodic preventive maintenance. Indirect methods are used for verifying or checking on a daily basis (routine checks). How often each method is used depends on the availability of instrumentation and qualified personnel, since direct measurement of a hood s performance can be both expensive and difficult. On the other hand, indirect methods are usually easier to use and can sometimes include inexpensive, continuously monitoring instruments (pressure gauges or velocity indicators). [Pg.1012]

For some hood types, measurements usually seen as indirect method, are used to measure the hood s performance to determine regulatory compliance. For example, regulations specify minimum and maximum face velocities for laboratory fume hoods and static pressure (negative) inside enclosed hoods. Continuously monitoring instruments can be connected to alarms that sound when the measurement is outside the specified limits. [Pg.1012]

The key phrase in this clause is or otherwise verified as it allows you to receive product into your company and straight onto the production line if you have verified that it conforms to the specified requirements before it arrives. An example of this is where you have performed acceptance tests or witnessed tests on the supplier s premises. You may also have obtained sufficient confidence in your supplier that you can operate a Just-in-time arrangement but you must be able to show that you have a continuous monitoring program which informs you of the supplier s performance. [Pg.379]

Because of their role as the link between producing and market areas, interstate natural gas pipelines play a crucial role in balancing supply and demand. To do so, the interstate pipelines continually monitor pipeline performance. These companies rely heavily on computers to gather, analyze and retain information on the performance of their pipelines, and to control the flow of gas in remote sections of the line. [Pg.836]

Continuous monitoring of the third-stage separator performance. If catalyst is showing up downstream, consider using more than the standard 3% flue gas underflow. The blowcase needs more attention than it usually gets. [Pg.264]

Continuous monitoring in use over a period of several years to insure continued performance and a replacement program that will take products out of service after a conservative use-life to preclude possible failure. [Pg.276]

Electrodeposition of metals can be performed under different electrochemical modes. In the work mentioned in Ref. [18], it was performed in potentiostatic mode. The potential value for formation of platinum nanoparticles is —25 mV vs. SCE the deposition is performed from 2.5 mM solution of H2[PtCl6] in 50 mM KCl. The size of nanoparticles formed depends on the reduction charge. Continuous monitoring of the charge in potentiostatic mode is provided by different potentiostats, for example, by Autolab-PG-stat (EcoChemie, The Netherlands). Conditions for deposition of other metals should be selected according to their electrochemical properties. [Pg.323]

One of the attractive features of SFE with CO2 as the extracting fluid is the ability to directly couple the extraction method with subsequent analytical methods (both chromatographic and spectroscopic). Various modes of on-line analyses have been reported, and include continuous monitoring of the total SFE effluent by MS [6,7], SFE-GC [8-11], SFE-HPLC [12,13], SFE-SFC [14,15] and SFE-TLC [16]. However, interfacing of SFE with other techniques is not without problems. The required purity of the CO2 for extraction depends entirely on the analytical technique used. In the off-line mode SFE takes place as a separate and isolated process to chromatography extracted solutes are trapped or collected, often in a suitable solvent for later injection on to chromatographic instrumentation. Off-line SFE is inherently simpler to perform, since only the extraction parameters need to be understood, and several analyses can be performed on a single extract. Off-line SFE still dominates over on-line determinations of additives-an... [Pg.429]

An RCRA permit for a hazardous waste combustion unit sets operating requirements that specify allowable ranges for, and requires continuous monitoring of, certain critical parameters that will ensure compliance with the performance standards. Operation within these parameters ensures that combustion is performed in the most protective manner and the performance standards are achieved. These parameters, or operating requirements, may include... [Pg.462]


See other pages where Performance continuous monitoring is mentioned: [Pg.248]    [Pg.283]    [Pg.8]    [Pg.1342]    [Pg.7]    [Pg.248]    [Pg.283]    [Pg.8]    [Pg.1342]    [Pg.7]    [Pg.71]    [Pg.274]    [Pg.442]    [Pg.499]    [Pg.28]    [Pg.701]    [Pg.1314]    [Pg.158]    [Pg.216]    [Pg.304]    [Pg.220]    [Pg.569]    [Pg.430]    [Pg.201]    [Pg.468]    [Pg.209]    [Pg.1242]    [Pg.417]    [Pg.448]    [Pg.63]    [Pg.88]    [Pg.309]    [Pg.587]    [Pg.521]    [Pg.445]   