Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Provide Continuous Monitoring Performance

Body Temperature Monitoring Internal body temperature, a potential confounding variable in the association between jet fuel constituent metabolism and performance/health measures, was monitored during the enrollee s work period. Selected subjects were asked to swallow a small pill-like sensor. The device provided continuous monitoring of body core temperature during the enrollee s work period. Other enrollees were asked to wear an aural or skin temperature probe. All enrollees wore Polar Band heart rate monitors around the chest area, and activity sensors on the wrist. [Pg.190]

Provide Continuous Monitoring of Performance is the final safety culture feature in the comprehensive CCPS book Guidelines for Risk Based Process Safety (KBPS) [9], The focus is leading and lagging indicators of a process safety culture (see Fig. 16.7). [Pg.440]

There are important economic consequences of a process being out of control for example, product waste and customer dissatisfaction. Hence, statistical process control does provide a way to continuously monitor process performance and improve product quahty. A typic process may go out of control due to several reasons, including... [Pg.735]

Electrodeposition of metals can be performed under different electrochemical modes. In the work mentioned in Ref. [18], it was performed in potentiostatic mode. The potential value for formation of platinum nanoparticles is —25 mV vs. SCE the deposition is performed from 2.5 mM solution of H2[PtCl6] in 50 mM KCl. The size of nanoparticles formed depends on the reduction charge. Continuous monitoring of the charge in potentiostatic mode is provided by different potentiostats, for example, by Autolab-PG-stat (EcoChemie, The Netherlands). Conditions for deposition of other metals should be selected according to their electrochemical properties. [Pg.323]

In this study we performed initial rate experiments, reacting H2S with lepidocrocite (23). The consumption of H2S was measured continuously by using a pH2S electrode cell (25). To avoid interferences of pH buffer solutions with the iron oxide surface, the pH was stabilized by using a pH-stat that added appropriate amounts of HC1 to the solution. The added volume, which was also continuously monitored, provided information about the amount of protons consumed during the reaction. Dissolved iron was measured only in some runs. [Pg.373]

Spectrophotometric assays for the HCV serine protease were performed on selected experimental agents using the method of Zhang (1). This assay is based on the proteolysis of chromogenic ester substrates and is suitable for continuous monitoring of HCV NS3 protease activity. Testing results are provided in Table 2. [Pg.364]

Reference items can be one or more items where a specific readout and well-known responses are expected. The reference item(s) is used to provide a basis for comparison with the test item or to compare the response of the test system to the test item. Reference items should be specific to the endpoint being measure, i.e., provide a known measurable or observable response. Reference item(s) should be tested for batch to batch variability and be appropriately characterized (e.g., purity, stability) and identified (e.g., CAS number). Solubility, stability, and purity need to be established for each reference item used, and acceptance criteria based on historical data developed. The continuous monitoring of the reference items is important to prove that the in vitro method continues to perform within the limits and consistent over time. [Pg.559]

Early radical kinetic values involved ESR methods, typically with continuous irradiation [16]. Much of the work had to be performed at low temperatures, and the resulting kinetic values at ambient temperatures could contain large errors. A modern variant of ESR spectroscopy removes the low-temperature requirement for relatively slow radical reactions and provides more precise data at ambient temperatures. The technique involves time-resolved ESR studies using pulsed photol-yses with continuous monitoring. It can be applied not only when the radicals of interest are formed instantly in the photochemical reaction but also when they are produced during the observing period from reaction of a first-formed transient [2]. [Pg.325]


See other pages where Provide Continuous Monitoring Performance is mentioned: [Pg.304]    [Pg.1085]    [Pg.148]    [Pg.173]    [Pg.433]    [Pg.440]    [Pg.440]    [Pg.228]    [Pg.61]    [Pg.616]    [Pg.192]    [Pg.158]    [Pg.538]    [Pg.95]    [Pg.259]    [Pg.247]    [Pg.99]    [Pg.58]    [Pg.254]    [Pg.253]    [Pg.125]    [Pg.732]    [Pg.626]    [Pg.20]    [Pg.97]    [Pg.365]    [Pg.214]    [Pg.253]    [Pg.669]    [Pg.29]    [Pg.1811]    [Pg.149]    [Pg.258]    [Pg.2679]    [Pg.2994]    [Pg.82]    [Pg.78]    [Pg.29]    [Pg.208]   
See also in sourсe #XX -- [ Pg.440 ]




SEARCH



Continuous monitoring

Performance continuous monitoring

Provide Continuous Monitoring

© 2024 chempedia.info