Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Polar organic compounds

Other Novel Solvents. In addition to molecules based on carboxylic and carbonic esters, other types of organic polar compounds were also explored as possible solvent candidates but with limited success. Zhang and Angell synthesized a dimeric glycol ester of boric ester (BEG, Table 12) in... [Pg.142]

At present, GAC is used most frequently for analysis of volatile compounds with various isotope compositions, of inorganic and organic gases, of volatile organic polar compounds, and of aqueous solutions of organic compounds. [Pg.1836]

Feedstocks come mainly from catalytic cracking. The catalyst system is sensitive to contaminants such as dienes and acetylenes or polar compounds such as water, oxygenates, basic nitrogen, organic sulfur, and chlorinated compounds, which usually require upstream treatment. [Pg.376]

Although httie or no reduction in total organic carbon occurs during ozonation, partially oxidized polar compounds (containing, COOH,... [Pg.502]

Physical properties of isopropyl alcohol are characteristic of polar compounds because of the presence of the polar hydroxyl, —OH, group. Isopropyl alcohol is completely miscible ia water and readily soluble ia a number of common organic solvents such as acids, esters, and ketones. It has solubiUty properties similar to those of ethyl alcohol (qv). There is a competition between these two products for many solvent appHcations. Isopropyl alcohol has a slight, pleasant odor resembling a mixture of ethyl alcohol and acetone, but unlike ethyl alcohol, isopropyl alcohol has a bitter, unpotable taste. [Pg.104]

Figure 2.21 shows the on-line extraction gas chromatogram of 2.25 ml of water spiked at 5 ppb levels with 14 different organic pollutants (40). In this case, the authors concluded that wall-coated open tubular traps (thick-film polysiloxane phases) can be used for the on-line extraction of organic compounds from water. However, when using swelling agents such as pentane, non-polar analytes can be trapped quantitatively, while for more polar compounds chloroform is the most suitable solvent. [Pg.38]

When analytes lack the selectivity in the new polar organic mode or reversed-phase mode, typical normal phase (hexane with ethanol or isopropanol) can also be tested. Normally, 20 % ethanol will give a reasonable retention time for most analytes on vancomycin and teicoplanin, while 40 % ethanol is more appropriate for ristocetin A CSP. The hexane/alcohol composition is favored on many occasions (preparative scale, for example) and offers better selectivity for some less polar compounds. Those compounds with a carbonyl group in the a or (3 position to the chiral center have an excellent chance to be resolved in this mode. The simplified method development protocols are illustrated in Fig. 2-6. The optimization will be discussed in detail later in this chapter. [Pg.38]

The toxicological or cumulative effect of illicit drugs on the ecosystems has not been studied yet. Moreover, their fate and transport in the environment is to a big extent still unknown. Due to their physical-chemical properties (octanol-water partition coefficient, solubility, etc.) some of them, such as cannabinoids, are likely to bioaccumulate in organisms or concentrate in sediments whereas the rest, much more polar compounds, will tend to stay in aqueous environmental matrices. However, continuous exposure of aquatic organisms to low aquatic concentrations of these substances, some of them still biologically active (e.g., cocaine (CO), morphine (MOR) and MDMA) may cause undesirable effects on the biota. [Pg.204]

Seed oils and waxes are more commonly extracted by SFE. It is the most suitable technique for non-polar compounds such as oils and waxes instead of other organic solvents, and it avoids the presence of solvent residues after extraction. Both extraction methods, the classical and SFE, stiU need the additional purification step of the extract, increasing the cost of the final product. [Pg.311]

All the preceding investigations have been concerned with polar compounds for which plansible mechanisms for their association with organic components of water, soil, and sediment may be more readily conceptualized. To provide a wider perspective, examples are given below for nentral compounds ... [Pg.209]

Celluloses (native or microcrystalline) are organic sorbents. They have a low specific surface area and are applied mainly in partition chromatography, especially for the separation of relatively polar compounds. Works on the topic include those by Whitton and coworkers [8], who examined biosynthetic pathways for the formation of taurine in vertebrates. Taurine and its precursor amino acids were extracted from tissues, and the purified supernatant was spotted onto cellulose plates. The... [Pg.201]

The open-column technique is commonly applied in the case of crude oils (being the least complex geochemical organic mixtures). MPLC, high-pressure liquid chromatography (HPLC), and PTLC are more often applied to more complex samples, especially those dominated by more polar compounds, such as hydrothermal bitumens or samples showing terrestrial organic matter input, such as extracts or pyroly-sates of coals of various ranks. [Pg.372]

Another variation of the preceding method is to apply HPLC to fractionate the cleaned-up aliphatic-aromatic fraction from flash colurim separation of soluble organic matter as it is performed in the Chevron laboratory, for example, as described in Reference 2. A Waters HPLC system equipped with a preparative Whatman Partisil 10 silica column (9.4 X 500 mm), a HPLC pump, and two detectors for separation monitoring (a UV and refractive index detector) are used, giving three fractions of aliphatic hydrocarbons, mono-, di-, and triaromatics and polar compounds. The hrst two fractions are eluted with hexane, whereas polar compounds are eluted with... [Pg.372]

This technique is based on the same separation mechanisms as found in liquid chromatography (LC). In LC, the solubility and the functional group interaction of sample, sorbent, and solvent are optimized to effect separation. In SPE, these interactions are optimized to effect retention or elution. Polar stationary phases, such as silica gel, Florisil and alumina, retain compounds with polar functional group (e.g., phenols, humic acids, and amines). A nonpolar organic solvent (e.g. hexane, dichloromethane) is used to remove nonpolar inferences where the target analyte is a polar compound. Conversely, the same nonpolar solvent may be used to elute a nonpolar analyte, leaving polar inferences adsorbed on the column. [Pg.877]

Most small organic molecules are soluble in mixed organic-aqueous solvents and can be easily analyzed using RPLC. However, there are some polar compounds which are not soluble in typical RPLC solvent systems or are unstable in an aqueous mobile phase system. These compounds can be analyzed on an RPLC column with a nonaqueous solvent system. This technique is called "nonaqueous reversed phase chromatography" (NARP).20-21 The NARP technique is primarily used for the separation of lipophilic compounds having low to medium polarity and a molecular weight larger than... [Pg.148]


See other pages where Polar organic compounds is mentioned: [Pg.112]    [Pg.262]    [Pg.374]    [Pg.71]    [Pg.191]    [Pg.7]    [Pg.346]    [Pg.112]    [Pg.262]    [Pg.374]    [Pg.71]    [Pg.191]    [Pg.7]    [Pg.346]    [Pg.351]    [Pg.196]    [Pg.164]    [Pg.331]    [Pg.411]    [Pg.308]    [Pg.2]    [Pg.79]    [Pg.87]    [Pg.217]    [Pg.21]    [Pg.22]    [Pg.316]    [Pg.83]    [Pg.380]    [Pg.383]    [Pg.384]    [Pg.338]    [Pg.408]    [Pg.876]    [Pg.420]    [Pg.423]    [Pg.680]    [Pg.147]    [Pg.94]    [Pg.110]    [Pg.235]    [Pg.271]   
See also in sourсe #XX -- [ Pg.245 ]




SEARCH



Organ polarity

Polar compounds

Polar organizers

© 2024 chempedia.info