Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Operating hours

Servicing of items is a routinely scheduled activity which is managed in the same way as inspection, and the periods between services will depend on the design of fhe equipment. The periods may be set on a calendar basis (e.g. every 24 months) or on a service hours basis (e.g. every 10,000 operating hours). [Pg.343]

The demonstration unit was later transported to the CECOS faciHty at Niagara Falls, New York. In tests performed in 1985, approximately 3400 L of a mixed waste containing 2-chlorophenol [95-57-8] nitrobenzene [98-95-3] and 1,1,2-trichloroethane [79-00-5] were processed over 145 operating hours 2-propanol was used as a supplemental fuel the temperature was maintained at 615 to 635°C. Another 95-h test was conducted on a PCB containing transformer waste. Very high destmction efficiencies were achieved for all compounds studied (17). A later bench-scale study, conducted at Smith Kline and French Laboratories in conjunction with Modar (18), showed that simulated chemical and biological wastes, a fermentation broth, and extreme thermophilic bacteria were all completely destroyed within detection limits. [Pg.499]

Considerable effort has been directed to determining the causes of connection failutes and to learning how to minimize the likelihood of occurrence. Acceptable failute rates range from <1 in 10 operating hours for contacts in air-frame (31) electrical systems and in some telecommunications equipment, to 100—1000 in 10 operating hours in instmments, to even larger rates for contacts in many consumer products. A failute is defined as exceedance of contact resistance, which can be as Httle as twice the initial contact resistance, that causes circuit malfunction. The required lifetimes of connectors may be >20 yr, although most required appHcation times ate shorter (see Materials reliability). [Pg.32]

Design considerations and costs of the catalyst, hardware, and a fume control system are direcdy proportional to the oven exhaust volume. The size of the catalyst bed often ranges from 1.0 m at 0°C and 101 kPa per 1000 m /min of exhaust, to 2 m for 1000 m /min of exhaust. Catalyst performance at a number of can plant installations has been enhanced by proper maintenance. Annual analytical measurements show reduction of solvent hydrocarbons to be in excess of 90% for 3—6 years, the equivalent of 12,000 to 30,000 operating hours. When propane was the only available fuel, the catalyst cost was recovered by fuel savings (vs thermal incineration prior to the catalyst retrofit) in two to three months. In numerous cases the fuel savings paid for the catalyst in 6 to 12 months. [Pg.515]

After the recommended operating hours, as shown in Table 10.3, the bearings should be taken out and washed thoroughly as prescribed above and fresh grease applied. The bearing covers and the bearing housing should also be washed. [Pg.236]

Since activated carbon lies to the left of the extractant and has a lower c, it will be used to remove the remaining load (0.0003 kg toluene/s, as shown by Fig. 3.19b). The flowrate of activated carbon is 0.015 kg/s. For 8000 operating hours per year, the annual operating cost of the system is 96,700/year. The annualized fixed cost can be calculated after equipment sizing (as shown in Example 2.1). [Pg.72]

Predictive maintenance is part of planned preventive maintenance. In order to determine the frequency of checks you need to predict when failure may occur. Will failure occur at some future time, after a certain number of operating hours, when... [Pg.360]

Both of the sources above contain tWo types of failure rate data used in CPQRAs time-related failure rates and demand-related failure rates. Time-related failure rates, presented as failures per 10 hours, are for equipment that is normally functioning, for example, a running pump, or a temperature transmitter. Data are collected to reflect the number of equipment failures per operating hour or per calendar hour. [Pg.7]

This data collection effort was concentrated on the following components because of their extensive populations and repair action documentation pumps, valves, electrical positioning devices, electric motors, and drives. For each component type, preface pages and data summary tables are provided. Separate data summary tables are provided for each component type and are structured in a format that allows for the inclusion of the number of pieces of operating equipment, the total number of operating hours, total number of failures, and hourly failure rates with upper and lower bounds. [Pg.66]

Where full canteen facilities are provided an accurate assessment of the hours of operation must be obtained so that plant and services are correctly sized. The operating hours will also greatly influence the need to provide separate plant from the main building, especially if meals are to be provided at the end of each shift. [Pg.59]

As with all convective systems, warm air heating installations produce large temperature gradients in the spaces they serve. This results in the inefficient use of heat and high heat losses from roofs and upper wall areas. To improve the energy efficiency of warm air systems, pendant-type punkah fans or similar devices may be installed at roof level in the heated space. During the operational hours of the heating system, these fans work either continuously or under the control of a roof-level thermostat and return the stratified warm air down to occupied levels. [Pg.412]

Absolute-fault alarm The third limit (absolute-fault alarm) is the most critical of the alert/alarm limits. When this limit is reached, the probability of catastrophic failure within 1000 operating hours is greater than 90 per cent. [Pg.718]

Scheduled maintenance is work based on known information, such as number of operations, hours mn, mileage, etc., and can therefore be carried out at a predetermined time interval. [Pg.785]

Plant and equipment that require a service on completion of a certain specified period of hours may, through experience, be catered for on a fixed frequency basis. If employed, this method avoids the need to record running hours (or, in the case of transport, mileage) on a daily or weekly basis to schedule the relevant planned maintenance. If it is essential that the maintenance of the plant and equipment be carried out on the completion of a certain number of operating hours or mileage, then this must be allowed for in the allocated work hours of the relevant trade group. [Pg.787]

The information on life-cycle costs gained with certain items of plant and equipment need not be true for a similar item in another location, as specific details on operating hours, and maintenance attendance can vary markedly. Also, it may be an auxiliary part (e.g. an electric motor) of a major component. Therefore, it may have an entirely different set of parameters. An important element that must be examined in detail when establishing life-cycle costs of a specific item of plant and equipment is the demand placed on energy resources by them. [Pg.791]

However, much more precision and attention to detail must be given to the installation of mechanical seals compared to conventional packing. Nevertheless, it is not unusual for mechanical seals to remain in service for many thousands of operational hours if they have been properly installed and maintained. [Pg.946]

EAR Energy Resources, which develops Zn-air batteries for portable computers, claims about 250 Wh for a computer unit. The price (in 1994) was 600, including the charger. For the first discharge, ten operating hours are claimed. However, it must be realized that the subsequent cycle behavior is not well established. Sony s Li... [Pg.72]

All the supported catalysts used gave TCE conversions less than 20% for the wet oxidation at 310 K, except for the 5 wt.% CoOx/Ti02, which had a steady-state conversion of 45% via a transient behavior in activity up to 1 h on stream (Fig. 1). Subsequently, there was negligible TCE conversion for the bare Ti02 during continuous operating hours near 6. [Pg.306]


See other pages where Operating hours is mentioned: [Pg.2]    [Pg.105]    [Pg.228]    [Pg.861]    [Pg.861]    [Pg.1774]    [Pg.237]    [Pg.771]    [Pg.811]    [Pg.811]    [Pg.101]    [Pg.162]    [Pg.537]    [Pg.726]    [Pg.59]    [Pg.77]    [Pg.475]    [Pg.204]    [Pg.265]    [Pg.2]    [Pg.33]    [Pg.67]    [Pg.84]    [Pg.122]    [Pg.219]    [Pg.222]    [Pg.222]    [Pg.222]    [Pg.282]    [Pg.59]    [Pg.460]    [Pg.552]    [Pg.126]   
See also in sourсe #XX -- [ Pg.18 , Pg.64 , Pg.110 , Pg.114 , Pg.128 ]




SEARCH



Cost drivers operating hours

HOUR

Hours of operation

Operation year-round 24-hour

Operations) hours

Operations) hours

© 2024 chempedia.info