Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Number system ratio test

Each sample batch contains replicates of two sets of standard calibrators which are placed at the beginning and end of the batch to bracket study samples and QC samples. The total numbers of QC samples from all levels should be >5 % of the number of unknown samples in the run and at a minimum of N= 2 at each level or N= 3 for Dilution QC. Minimum three system suitability test samples (SST) should be included in the beginning of the batch (1) SST-LLOQ sample to evaluate the signal to noise ratio of the instrument on the day of the analysis. (2) SST-QCO sample (a blank sample is fortified with IS) to evaluate any potential contamination of IS solution. (3) SST-Control blank (a double blank sample) to evaluate any interference or contamination of the blank matrix lot. [Pg.61]

Edgren carried out a number of studies in which bioassays were used to compare the widely differing potencies of a number of analogues of 17/i-oestradiol that were modified in the 18-position. Commenting on the use of potency ratios, Edgren concluded that they were only valid for specific substances and test systems and useless for product safety testing . These problems could have important consequences for any attempt to establish the potency of specific environmental EDs or environmentally relevant mixtures. [Pg.20]

Geometric similarity requires all corresponding dimensions of a new system to have the same ratio with a test model which has proven acceptable. These dimensions should include vessel diameter and liquid level, baffle width and number in vessel, impeller diameter, number of blades and width ratio. For example, a tank four times the diameter of the original model also requires a turbine ten times the diameter of the original turbine. [Pg.313]

Immunological abnormalities were reported in 23 adults in Woburn, Massachusetts, who were exposed to contaminated well water and who were family members of children with leukemia (Byers et al. 1988). These immunological abnormalities, tested for 5 years after well closure, included persistent lymphocytosis, increased numbers of T-lymphocytes, and depressed helper suppressor T-cell ratio. Auto-antibodies, particularly anti-nuclear antibodies, were detected in 11 of 23 adults tested. This study is limited by the possible bias in identifying risk factors for immunological abnormalities in a small, nonpopulation-based group identified by leukemia types. Other limitations of this study are described in Section 2.2.2.8. A study of 356 residents of Tucson, Arizona, who were exposed to trichloroethylene (6-500 ppb) and other chemicals in well water drawn from the Santa Cmz aquifer found increased frequencies of 10 systemic lupus erythematosus symptoms, 5 (arthritis, Raynaud s phenomenon, malar rash, skin lesions related to sun exposure, seizure or convulsions) of which were statistically significant (Kilbum and Warshaw 1992). [Pg.93]

In another reaction dendritic pyridine derivatives such as 82 or 83 were tested as co-catalysts for enantioselective cyclopropanation of styrene with ethyl diazoacetate [102]. Using catalyst 82, enantiomer ratios of up to 55 45 were obtained. However, with catalyst 83 bearing larger branches yields and selectivities did not increase. The relatively low selectivities were rationalized by the presence of a large number of different conformations that this non-rigid system may adopt. [Pg.166]

The number of scientific articles published on meteorites has increased dramatically in the last few years few of these, however, concern themselves with small meteorites, the size of which lies between that of the normal meteorites (from centimetres to metres in size) and that of interplanetary dust particles. In the course of an Antarctic expedition, scientists (mainly from French institutions) collected micrometeorites from 100 tons of Antarctic blue ice (Maurette et al 1991). These micrometeorites were only 100 400 pm in size five samples, each consisting of 30-35 particles, were studied to determine the amount of the extraterrestrial amino acids a-aminoisobutyric acid (AIBS) and isovaline—both of which are extremely rare on Earth—which they contained. The analysis was carried out using a well-tested and extremely sensitive HPLC system at the Scripps Institute, La Jolla. Although the micrometeorites came from an extremely clean environment, the samples must have been contaminated, as they all showed traces of L-amino acids. Only one sample showed a significantly higher concentration of AIBS (about 280 ppm). The AIBS/isovaline ratio in the samples also lay considerably above that previously found in CM-chondrites. [Pg.71]

Engineers commonly use dimensionless ratios such as the Reynolds number and the lift coefficient to help understand complex experimental data, organize equations and model building, and relate model testing in a wind tunnel to that of a prototype flight. This kind of analysis is called dimensional analysis because it uses the dimensional nature of important variables to derive dimensionless parameters that determine the scaling properties of a physical system. [Pg.182]

If such enzymes occur at the same levels in relevant microbial populations, Vmax may be directly related to other metrics of biomass presence such as cell numbers, biomass dry weight, or protein concentrations. In an attempt to enable extending results from one system to another (e.g., from laboratory observations to field situations), one often normalizes Fmax by such biomass parameters. For example, in Table 17.7, the observed Vmax values are normalized to the protein contents of the tested microbial populations or isolated enzymes, and the result is given as values Vmax (the prime is added to emphasize the normalization). To apply such information to new situations, one must multiply the normalized maximum velocities by a measure of the relevant enzyme concentration or biomass protein in the new system of interest (e.g., Vmax x microbial protein content in new case involving intact microorganisms). Of course, one is assuming that the ratio of enzyme to total protein is the same in the old and new situation. [Pg.757]

At integrating (305) for the conditions of a flow system (93, 98), it proved to be convenient to introduce a constant k proportional to k. The value of k was also calculated from data obtained in circulation flow systems (4, 96, 99-103). If the volume of ammonia reduced to 0°C and 1 atm, formed in unit volume of catalyst bed per hour, is accepted as a measure of reaction rate, then k = (4/3)3 1 m)k (101). The constancy of k at different times of contact of the gas mixture with the catalyst and different N2/H2 ratios in the gas mixture can serve as a criterion of applicability of (305). Such constancy was obtained for an iron catalyst of a commercial type promoted with A1203 and K20 at m = 0.5 (93) from our own measurements at atmospheric pressure in a flow system and literature data on ammonia synthesis at elevated pressures up to 100 atm. A more thorough test of applicability of (305) to the reaction on a commercial catalyst at high pressures was done by means of circulation flow method (99), it confirmed (305) with m = 0.5 for pressures up to 300 atm. Similar results were obtained in a large number of investigations by different authors in the USSR and abroad. These authors, however, have obtained for some promoted iron catalysts m values differing from 0.5. Thus, Nielsen et al. (104) have found that m 0.7. [Pg.253]

It has been explained that when testing mixture diagrams, factor space is usually a regular simplex with q-vertices in a q-1 dimension space. In such a case, the task of mathematical theory of experiments consists of determining in the given simplex the minimum possible number of points where the design points will be done and based on which coefficients of the polynomial that adequately describes system behavior will be determined. This problem, for the case when there are no limitations on ratios of individual components, as presented in the previous chapter, was solved by Scheffe in 1958 [5], However, a researcher may in practice often be faced with multicomponent mixtures where definite limitations are imposed on ratios of individual components ... [Pg.506]


See other pages where Number system ratio test is mentioned: [Pg.306]    [Pg.237]    [Pg.179]    [Pg.532]    [Pg.192]    [Pg.204]    [Pg.153]    [Pg.179]    [Pg.576]    [Pg.482]    [Pg.587]    [Pg.266]    [Pg.203]    [Pg.410]    [Pg.140]    [Pg.79]    [Pg.153]    [Pg.169]    [Pg.356]    [Pg.46]    [Pg.19]    [Pg.561]    [Pg.347]    [Pg.370]    [Pg.419]    [Pg.289]    [Pg.705]    [Pg.17]    [Pg.118]    [Pg.388]    [Pg.128]    [Pg.57]    [Pg.11]    [Pg.36]    [Pg.1156]    [Pg.76]    [Pg.154]    [Pg.38]    [Pg.7]    [Pg.165]   
See also in sourсe #XX -- [ Pg.56 ]




SEARCH



Numbering system

Numbers ratios

System testing

Systemization numbers

Test systems

© 2024 chempedia.info