The air is streaming through the supply pipes directly into the blade which is mounted on a turntable. The blade is measured in different positions, so that all important surface areas can be examined. The time for a complete blade examination is approximatly 5 minutes. The blades or vanes are mounted manuell, otherwise the process is running fully automatically. [Pg.402]

For testing under field conditions a new mobile version of introscope has been developed, mounted on a lorry with high cross-country capability and self-contained power supply. [Pg.452]

The changes described above also allowed much easier access to the high voltage cable for routine (6-month) owner directed, service operations, and provided better upper and lower x-ray cabinet and control cabinet ventilation. With the exception of the x-ray tubes, all the individual manufactured components, on all four systems are identical. There are very subtle differences in the warm-up/start-up sequence on the x-ray controllers on the newer systems due to model/year and x-ray tube differences. The last three systems were supplied with environmental type key-boards for the image processors and base-mounted , rather than conduit-mounted exterior warning indicators. The first system was subsequently upgraded to include the better keyboard and the external warning appliances/features. [Pg.611]

The method is based on the international standard ISO 4053/IV. A small amount of the radioactive tracer is injected instantaneously into the flare gas flow through e.g. a valve, representing the only physical interference with the process. Radiation detectors are mounted outside the pipe and the variation of tracer concentration with time is recorded as the tracer moves with the gas stream and passes by the detectors. A control, supply and data registration unit including PC is used for on site data treatment... [Pg.1054]

In other designs, a diffused siUcon sensor is mounted in a meter body that is designed to permit caUbration, convenient installation in pressure systems and electrical circuits, protection against overload, protection from weather, isolation from corrosive or conductive process fluids, and in some cases to meet standards requirements, eg, of Factory Mutual. A typical process pressure meter body is shown in Figure 10. Pressure measurement from 0—746 Pa (0—3 in. H2O) to 0—69 MPa (0—10,000 psi) is available for process temperatures in the range —40 to 125°C. Differential pressure- and absolute pressure-measuring meter bodies are also available. As transmitters, the output of these devices is typically 4—20 m A dc with 25-V-dc supply voltage. [Pg.25]

Enclosed motors with air-to-water coolers cost much less than TEF( motors above 373 kW (5()0 hp) in large svnchronoiis-rnotor ratings, thev cost even less than weather-protected, tvpe II, Large enclosed synchronous machines with coolers for mounting in the motor foundation are frequently supplied at lower cost than motors with integral-mounted coolers. [Pg.2488]

In the first two types a brake shoe, operated by an external auxiliary supply, is mounted on the extended shaft at the NDE (non-driving end) of the motor. These brakes are normally operated after the motor is switched OFF. The heat of braking appears in the external circuit and the motor windings are not affected. For motors with this braking, only the starting heat need be considered, depending upon the frequency of starts and not the heat of braking. [Pg.151]

Cathodes made of steel tube rings 10 m in diameter are used m the internal protection of several 30-m-high caustic soda stirring tanks, each with a surface area of 3100 m, The cathodes were insulated and mounted on supporting brackets. The current supply was via armored parallel connected cables. One-inch bolts were used for the entrance in the tank wall as shown in Fig. 21 -13 for a feed current of 500 A. The size of the cathodes has to be such that they can maintain sufficient cathodic protection current. The surface ratio of the object to be protected and the... [Pg.482]

Lube oil units are typieally available in two versions the manu-faeturer s standard or in aeeordanee with API Standard 614. The major eomponents of a unit are the oil tank, auxiliary oil pump, double filter and, seleetively, one or two oil eoolers. All eomponents of the smaller units are mounted on a eommon bedplate, separated from the other eomponents. The oil ean be heated by an eleetrieal or steam-powered heating unit. The neeessary instrumentation is a standard supply item and, if requested, the switehes and motors ean be prewired. The main and auxiliary oil pumps are driven by different types of drivers (e.g., one by an eleetrie motor and the other by either a small steam turbine or by direet eonneetion to the shaft end of a major maehine easing in the turbotrain). [Pg.129]

Lube oil level in the reservoir should be monitored by a sensing deviee to indieate low lube oil level. Loeal and panel-mounted pressure gauges are neeessary to monitor operation of the lube oil system and must be ineluded in the manufaeturer s seope of supply. The purehaser must distinguish between eontrol room instrumentation and instruments mounted on a stand-alone (loeal) panel. There is also a tendeney to plaee monitoring instruments on auxiliary equipment and piping. While this may eost less, it often eomplieates tlie operator s surveillanee tasks. [Pg.279]

This node(s) presents a different problem. Its AC voltage can be easily capac-itively coupled into any adjacent traces on different metal layers, as well as radiate EMI. Unfortunately, it is generally the trace that must also act as a heatsink for both the power switch and the rectifiers, especially in surface mount power supplies. Electrically, the trace wants to be as small as possible, but thermally, it wants to be large. There is one good compromise in the surface mount designs, and that is to make the top PCB island identical to the bottom PCB island and connect them with numerous vias (or thru-hole connections). This can be seen in Figure 3-62. [Pg.98]

The transformer is going to be the only nonsurfaee mount eomponent inside the power supply beeause there is no surfaee mount eore style large enough to support 15 W. A toroid will work but I will be using a low profile E-E eore from TDK. The EPC style of low profile eores will do. [Pg.171]

In surfaee mount printed eireuit board applieations, more than one issue usually must be eonsidered. Heatsinking must be eonsidered, along with signal and EMI/RFI eonsiderations. The traee that must dissipate the greatest heat within a switehing power supply is also the node that has the largest dv/dts whieh eouple very easily to the surrounding traees. [Pg.192]

There are several suppliers of electron accelerators suitable for remote repair of composites, including Varian, Siemans, and Schonberg. At present, the only manufacturer of suitable portable electron accelerators is Schonberg Radiation Corporation of Santa Clara, California. Field repair of damaged aircraft components can be accomplished with a remotely controlled, truck-mounted accelerator. Table 13 gives the characteristics for several electron accelerators, all portable, supplied by Schonberg. Fig. 5 shows a schematic layout of a 10-MeV accelerator... [Pg.1030]

When solution must be pumped, consideration should be given to use of holding tanks between the dry feed system and feed pumps, and the solution water supply should be controlled to prevent excessive dilution. The dry feeders may be started and stopped by tank level probes. Variable-control metering pumps can then transfer the alum stock solution to the point of application without further dilution. Means should be provided for calibration of the chemical feeders. Volumetric feeders may be mounted on platform scales. Belt feeders should include a sample chute and box to catch samples for checking actual delivery with set delivery. Gravimetric feeders are usually furnished with totalizers only. Remote instrumentation is frequently used with gravimetric equipment, but seldom used with volumetric equipment. [Pg.95]

Bulk unloading facilities usually must be provided at the treatment plant. Rail cars are constructed for top unloading and therefore require an air supply system and flexible connectors to pneumatically displace the alum from the car. U.S. Department of Transportation regulations concerning chemical tank car unloading should be observed. Tank truck unloading is usually accomplished by gravity or by a truck mounted pump. [Pg.95]


See other pages where Mounting supplies is mentioned: [Pg.230]    [Pg.522]    [Pg.230]    [Pg.522]    [Pg.571]    [Pg.27]    [Pg.58]    [Pg.65]    [Pg.150]    [Pg.870]    [Pg.270]    [Pg.474]    [Pg.69]    [Pg.412]    [Pg.508]    [Pg.509]    [Pg.145]    [Pg.926]    [Pg.1105]    [Pg.1595]    [Pg.1741]    [Pg.341]    [Pg.957]    [Pg.237]    [Pg.277]    [Pg.266]    [Pg.517]    [Pg.566]    [Pg.244]    [Pg.260]    [Pg.445]    [Pg.352]    [Pg.97]    [Pg.535]    [Pg.446]   