Mounting practices

The patented system (15) has stationary disks mounted inside a pressure vessel (horizontal vessel, vertical disks) which is mounted on rollers and can rotate slowly about its axis. A screw conveyor is mounted in the stationary center of rotation it conveys the cake, which is blown off the leaves when they pass above the screw, to one end of the vessel where it falls into a vertical chute. The cake discharge system involves two linear sHde valves that sHde the cake through compartments which gradually depressurize it and move it out of the vessel without any significant loss of pressure. The system rehes entirely on the cake falling freely from one compartment to another as the valves move across. This may be an unrealistic assumption, particularly with sticky cakes when combined with lots of sliding contact surfaces which are prone to abrasion and jamming, the practicality of the system is questionable. [Pg.406]

The active immunotherapeutic approach is specific and based on the premise that tumor antigens are immunogenic and the host is sufficientiy immunocompetent to mount an effective immune response to an autologous tumor. Theoretically, a weak or suppressed host immune system that had allowed the formation of a tumor may be overridden by active immunization or immunostimulation. In practice, vaccines composed of so-called autologous tumor extracts have been used to treat patients with malignant melanoma (73), and purified melanoma tumor-associated antigens have been used to ehcit antibody responses in melanoma patients (74). [Pg.41]

Test Methodfor Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method, ASTM C423-90a, ASTM, Philadelphia, Pa., 1990. Standard Practices for Mounting Test Specimens During Sound Absorption Tests, ASTM E795-92, ASTM, Philadelphia, Pa., 1992. [Pg.321]

Peroxyxanthates. A new factor ia the theory and practice of flotation was found ia the Mount Isa, AustraUa, copper flotation solution. Secondary butyl perxanthate was formed by the reaction of the xanthate with hydrogen peroxide ia dilute alkaline aqueous solution and was found to be identical to a substance from the flotation solution ... [Pg.365]

The labyrinth sleeve can be flexibly mounted to permit radial motion for self-ahguiug effects. In practice, a radial clearance of under 0.008 is difficiilt to achieve. [Pg.939]

The Mix-R-Step type in Fig. ll-62e is an adaptation of avibratoiy conveyor. It features better heat-transfer rates, practically doubling the coefficient values of the standard flat surface and trebling heat-flux values, as the layer depth can be increased from the norm 13 to 25 and 32 mm (V2 to 1 and F in). It mav be provided on decks jacketed for air, steam, or water spray. It is also often apphcable when an infrared heat source is mounted overhead to supplement the indirect or as the sole heat source. [Pg.1097]

Two-Roll Mills These mills contain two parallel rolls mounted in a heavy frame with provision for accurately regulating the pressure and distance between the rolls. As one pass between the rolls does little blending and only a small amount of work, the mills are practically always used as batch mixers. Only a small amount of material is in the high-shear zone at any one time. [Pg.1646]

Since card and ring frame motors are normally mounted inside the machine frame, there is an obvious obstruction in the cooling. With this in mind and to meet the torque requirements, the common practice is to choose the next... [Pg.167]

In outdoor type switchgear or controlgear assemblies the normal practice is to provide a double door in the front to house the front panel and protect the door knobs, meters, lights, pushbuttons, reset knobs or other accessories mounted on the door and thus prevent water or dust leaking through joints, knockouts and fitments etc. It is also recommended to have a canopy on the top of the enclosure to protect the panel from direct rain. Figures 13.6 and 13.28 illustrate this type of construction. [Pg.362]

Since it is not practical to manufacture a llameproof enclosure due to its size and bulk and the number of knockouts and openings on the doors for switches, metering, indicators, and pushbuttons (PBs) etc., it is common practice to locate the.se assemblies some distance from the affected area in a separate well-ventilated room. Depending upon the location and intensity ol contamination, it may be permissible to meet the requirement by using a pressurized enclosure by maintaining a positive pressure inside the enclosure similar to that for motors (Section 7.1.3..3). When there arc many switchgear assemblies, the room itself can be pressurized, which is safer and easier. Small enclosures, however, such as a PB station, switch or a switch fuse unit or an individual starter unit etc., which can be easily made of MS plates or cast iron, as discussed in Section 7.13, can be mounted in the hazardous area while the main MCC can be installed in the control room, away from the contaminated area and from where the process can be monitored. [Pg.363]

Manufacturers may adopt different practices to mount the main and auxiliary busbars, depending upon the size, rating and fault level of the system. Some of the recommended and more common of these are illustrated in Figure I3.30(a)-(d) and discussed briefly below,... [Pg.368]

To obtain a strong busbar mounting system, suitable to withstand the electrodynamic forces arising out of a system fault, modern practice is to make use of thermosetting plastics, such as DMC (Dough Moulding Compounds)... [Pg.368]

The normal practice is to mount each phase units on separate platforms, insulated for 33 kV from each other. [Pg.802]

Recommended Practices for Mounting Buses and Making Bus Joints... [Pg.903]

Recommended practices to mount buses and make bus connections... [Pg.990]

Sometimes in practice the dial indicators are mounted on the couplings, but it is best to mount and fix the indicatttrs onto the shafts because the couplings may be eeeentrie to the shaft centerlines. Rotate the shafts and obtain the displacement readings. Project these readings graphically (tr mathematically to the motor base t(t determine the adjustments required, and the spacing shims under each foot. [Pg.145]

Does your house have air conditioning, or a heat pump Do you have solar he,- ig, a Jacu22i bath, swimming pool, aquarium, solar heating, a roof mounted water storage tank, a well, a power assisted commode, a motorboat, a jet ski, ATV or camper Then you have even more mechanical sealed pumps. We have mechanical sealed pumps in practically all facets of our everyday life, and these pump seals last for years wii problems. [Pg.181]

Review the motor requirements and specifications to make sure that all the unnecessary, nonstandard, special features have been eliminated. Each special requirement such as nonstandard mounting dimensions and nonstandard bearings should be eliminated unless it can be demonstrated the feature is cost effective. In actual practice, many special features are specified because of an isolated case of trouble that occurred years ago. Likewise, some special features may become obsolete through changes in refinery or chemical plant practice or through improved manufacturing techniques. [Pg.257]


See other pages where Mounting practices is mentioned: [Pg.623]    [Pg.623]    [Pg.898]    [Pg.1692]    [Pg.99]    [Pg.479]    [Pg.543]    [Pg.23]    [Pg.244]    [Pg.324]    [Pg.1785]    [Pg.2328]    [Pg.2328]    [Pg.20]    [Pg.445]    [Pg.452]    [Pg.547]    [Pg.759]    [Pg.768]    [Pg.502]    [Pg.110]    [Pg.311]    [Pg.298]    [Pg.439]    [Pg.351]    [Pg.441]    [Pg.430]    [Pg.885]    [Pg.5]    [Pg.776]    [Pg.33]    [Pg.697]   