Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Minimal cassette

Minimal cassettes Eliminates vector backbone. Simpler transgenic loci. Higher expression levels. Reduced silencing Particle bombardment only 25-28... [Pg.257]

Assure that the bottom point (between the extension and the conical black piece) of the cassette is sealed tightly with a shrink band of electrical tape. Point the open end of the cassette down to minimize contamination. [Pg.245]

Liu, W., Ahlert, J., Gao, Q. et al. (2003) Rapid PCR amplification of minimal enediyne polyketide synthase cassettes leads to a predictive familial classification model. Proceedings of the National Academy of Sciences of the United States of America, 100, 11959. [Pg.258]

Adrenoleukodystrophy is an X-linked dysmyelinative disorder caused by mutations in the ABCD1 gene, which encodes the peroxisomal integral membrane ALD protein, a member of the ATP binding cassette transporter family. These mutations result in impaired clearance of plasma very-long-chain fatty acids. Affected males may present with symmetrical distal axonal polyneuropathy, adrenocortical insufficiency or CNS demyelination, while occasional heterozygous women demonstrate deficits suggestive of multiple sclerosis [56]. Manipulation of dietary fatty acid intake has some minimal therapeutic effect, while bone marrow transplantation has diminished deficits in a few patients. (See in Ch. 41.)... [Pg.624]

Enclose the gel in a piece of plastic wrap and place it in a film cassette. Using a felt-tipped pen, mark the film in a manner that will allow you to determine position of gel on the film after it is developed. Expose the gel to a piece of Kodak X-omat film for 18 hr at — 70°C. By exposing the film at low temperature, radioactive scattering will be minimized, giving you well-defined radioactive protein bands on the autoradiogram. [Pg.249]

Potential artifacts with the KO approach also include unanticipated changes from the DNA cassette itself plus insertion site effects (58), although insertion sire artifacts should be minimal in the oq-AR KOs (Table 1). More notably, each of the oq-AR KOs is systemic and lifelong, with the possibility that developmental and compensatory changes will mask a phenotype and produce a false negative or cause a secondary effect on phenotype related only indirectly to oq-AR deletion. For example, it is very likely that any KO (or TG for that matter) that changes cardiac or vascular function will alter sympathetic activity, with secondary effects via other ARs. Indeed, we saw sympathetic activation in the single A KO (2). [Pg.235]

One approach to minimizing these risks is by limiting the overall dose of NCEs administered. Typically, total oral doses of 5—10 mg/kg are considered acceptable. For a cassette composed of five NCEs, this translates to a dose of 1 to 2 mg/kg/compound. For intravenous administration, typical total doses range from 3 to 5 mg/kg, resulting in an individual NCE dose of 0.6 to 1 mg/kg/ compound. However, in some cases, limited analytical assay sensitivity may not permit dose reductions. In such cases, a reduction in the number of NCEs administered per cassette could be considered in lieu of or in addition to a reduction in the total dose administered. [Pg.362]

For this reason, when a cassette is composed of structurally diverse compounds, it is usually prudent to use protein precipitation as a plasma sample preparation technique. Although the absolute recovery will vary from compound to compound, this approach can be applied with fairly universal success across a wide structural range of compounds and assay development time will be minimal. Generic solid-phase extraction protocols can also be effective, but will experience a higher (10 to 15% of compounds) failure rate. Chapter 6 contains examples of generic extraction protocols that can be adapted for use with cassettes containing diverse NCEs. [Pg.367]

As with most LC/MS experiments, the analytical separation is a necessary part of multicomponent quantitation in cassette dosing for three reasons (i) separations are an important tool for managing collision-cell cross talk, (ii) to minimize possible in-source fragmentation from metabolites, and (iii) to minimize the unique ion-suppression circumstances that can occur in multicomponent quantitation (see Chaps. 3 and 5). [Pg.367]

Under the best circumstances, compounds are selected for cassettes with their analytical characteristics in mind. In this way, the chances of experimental success are improved. Although it would be useful to choose compounds so as to minimize drug—drug interaction issues, there is generally not enough pharmacological... [Pg.371]

An enclosed collection cassette has four individual compartments, into which a robot places the various tubes/collection vials, as shown in Fig. 8. After a fraction is collected, the robot returns the fraction to the original position of the tube/vial. This design limits the user to no more than four fractions per injection. However, this hardware is intended to be used with analytical SFC-MS, which identifies the correct peak and its retention time. A spreadsheet is created which relates analytical retention time windows to the desired peak. The chromatography is directly scaled to the semiprep level and the retention time windows are passed to the semiprep hardware. In most cases, a single fraction is collected. The analytical SFC-MS is intended as a form of triage to eliminate as many marginal samples as possible to minimize the number of prep runs. With MS tracking, the intent is to collect one peak per injection. [Pg.534]

Design to minimize the risk of contact between the operational person and the oral fluid Sample expressed into self-contained vial Sample expressed into separate vial. Verified through field study reports Sample does not overflow test cassette or test strip when transferred by pouring or pipetting ... [Pg.228]

The capillary cassette was placed directly on the heating surface of the thin-film resistive heater to minimize thermal capacitance. A Plexiglas frame was used to hold the assembly and allow access of the cooling air flow from the fans to the capillary cassette. [Pg.446]


See other pages where Minimal cassette is mentioned: [Pg.256]    [Pg.258]    [Pg.256]    [Pg.258]    [Pg.276]    [Pg.344]    [Pg.67]    [Pg.93]    [Pg.74]    [Pg.142]    [Pg.200]    [Pg.224]    [Pg.255]    [Pg.321]    [Pg.168]    [Pg.424]    [Pg.353]    [Pg.262]    [Pg.274]    [Pg.501]    [Pg.90]    [Pg.38]    [Pg.38]    [Pg.1974]    [Pg.370]    [Pg.114]    [Pg.261]    [Pg.363]    [Pg.368]    [Pg.368]    [Pg.372]    [Pg.38]    [Pg.184]    [Pg.269]    [Pg.191]    [Pg.140]    [Pg.394]    [Pg.38]   
See also in sourсe #XX -- [ Pg.256 ]




SEARCH



Cassettes

© 2024 chempedia.info