The second question is, however, still being discussed (see, e.g., 180) Gault et al. studied the butenes/D2 exchange and came to conclusions which were supported by the data of mass and microwave spectrometries (183-185)— namely, the dissociative adsorption produces on some metals intermediates... [Pg.167]

Many furan derivatives have been examined by X-ray diffraction methods, and natural products (especially the terpenoids) have provided numerous, interesting subjects for study. Some work has also been done by electron diffraction methods and, more recently, by microwave spectrometry. The bond lengths and angles determined for furan and assembled... [Pg.535]

Maser amplifiers are used where the requirement for a very low noise amplifier outweighs the technological problems of cooling 10 low temperatures. They have been used in passive and active radiostronomical work, in satellite communications, and us preamplifiers for microwave spectrometry The ammonia and the atomic hydrogen masers have been studied as frequency standards and have heen used in accurate tests of special relativity. [Pg.971]

Epsilon Industrial has pioneered a concept for the measurement of constituents in pumpable process described as guided microwave spectrometry (GMS) (Epsilon 1994). GMS was originally developed as a means for determining moisture content (0 to 100%), salinity and other molecular concentrations but has been recently been expanded to foods as well as many other applications. [Pg.225]

An alternative mechanism is required to explain some peculiarities of the aromatization of -heptane on Pt/AljOj. The distribution, determined by microwave spectrometry, of the toluenes from n-heptane-l- C, is methyl-( C), 50% ortho- C, 34% meta- C, 16% (94). These results can be compared to those obtained by Davis (757) with n-heptane- 1- C. [Pg.56]

Most published applications of microwave spectrometry have taken data from samples at Pa pressures. It is widely recognised, however, that the technique would be far more useful if it could deal directly with samples at atmospheric pressure and some recent work has been directed to this end and is discussed in Chapters 5 and 6. Linewidths at atmospheric pressure are 6 GHz making it essential for frequency scanning spectrometers to employ wideband MMW sources, but at the same time the requirement for source frequency stability is much reduced. [Pg.76]

J.F. Alder, M.F. Brennan, I.M. Clegg, P.K.P. Drew and G. Thinip, Application of Microwave Spectrometry, Permittivity and Loss Measurements to Chemical Analysis, Trans. Inst. Meas. Control, 1983, 5, 99-111. [Pg.87]

Another reason for interest in microwaves in chemical technology involves the fields of dielectric spectrometry, electron spin resonance (esr), or nuclear magnetic resonance (nmr) (see Magnetic spin resonance). AppHcations in chemical technology relating to microwave quantum effects are of a diagnostic nature and are not reviewed herein. [Pg.337]

In the structure sections, labelled compounds have often been used to solve a spectroscopic problem involved in microwave (Section 4.04.1.3.2), nitrogen NMR (Section 4.04.1.3.5), IR (Section 4.04.1.3.7(i)) or mass spectrometry (Section 4.04.1.3.8). The synthesis usually involves non-radioactive compounds ( H, N) by classical methods that must be repeated several times in order to obtain good yields. [Pg.289]

SOME NEW ADVANCES IN DEVELOPING MICROWAVE PLASMA TORCH SPECTROMETRY... [Pg.14]

COMPARISON OF MICROWAVE ASSISTED EXTRACTION METHODS FOR THE DETERMINATION OF PLATINUM GROUP ELEMENTS IN SOIL SAMPLES BY ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY AFTER PHASE SEPARATION-EXTRACTION... [Pg.290]

During the past decade, MALDI-TOF MS has proven to be an effective tool for the analysis of oligo- and polymeric mannoglucans (for extensive reviews see [222,223]). SEC/MALDI mass spectrometry was employed in the analysis of hemicelluloses isolated by microwave heat-fractionation from spruce and aspen wood [94]. These methods allowed the separation and characterization of the oligo- and polysaccharide fractions derived from the xylan and mannan components of both woods [224]. [Pg.29]

It is well established that disulfur difluoride (S2F2) exists in two isomeric forms, the nonplanar disulfane FSSF and the branched thiosulfoxide form p2S=S, with the latter found to be the more stable isomer. Both isomers have been characterized by microwave spectroscopy, mass spectrometry, infrared and Raman spectroscopy as well as photoelectron spectra [6] (and refer-... [Pg.4]

Minganti V, Capelli R, Depellegrini R (1995) Evaluation of different derivatization methods for the multielement detection of Hg, Pb and Sn compounds by gas chromatography-microwave induced plasma-atomic emission spectrometry in environmental samples. Fresenius Journal of Analytical Chemistry, 351 (4-5) 471 77. [Pg.48]

Raw foods were freeze-dried and analyzed for carbon isotopes using mass spectrometry. Cooked foods were prepared following historic recipes, then were freeze-dried prior to analysis. For the trace element analysis, foods (both raw and cooked) were wet ashed using nitric acid in Teflon lined pressure vessels and digested in a CEM Microwave oven. Analysis of Sr, Zn, Fe, Ca and Mg was performed using Atomic Absorption Spectrometry in the Department of Geology, University of Calgary. [Pg.5]

Specifically for triazines in water, multi-residue methods incorporating SPE and LC/MS/MS will soon be available that are capable of measuring numerous parent compounds and all their relevant degradates (including the hydroxytriazines) in one analysis. Continued increases in liquid chromatography/atmospheric pressure ionization tandem mass spectrometry (LC/API-MS/MS) sensitivity will lead to methods requiring no aqueous sample preparation at all, and portions of water samples will be injected directly into the LC column. The use of SPE and GC or LC coupled with MS and MS/MS systems will also be applied routinely to the analysis of more complex sample matrices such as soil and crop and animal tissues. However, the analyte(s) must first be removed from the sample matrix, and additional research is needed to develop more efficient extraction procedures. Increased selectivity during extraction also simplifies the sample purification requirements prior to injection. Certainly, miniaturization of all aspects of the analysis (sample extraction, purification, and instrumentation) will continue, and some of this may involve SEE, subcritical and microwave extraction, sonication, others or even combinations of these techniques for the initial isolation of the analyte(s) from the bulk of the sample matrix. [Pg.445]

Huang M, Hirabayashi A, Shirasaki T, Koiznmi H (2000) A multimicrospray nebulizer for microwave-induced plasma mass spectrometry. Anal Chem 72 2463-2467 Ivanovich M, Murray A (1992) Spectroscopic methods. In Uranium-Series Disequilibrium Applications to Earth, Marine, and Enviromnental Sciences, 2" Ed. Ivanovich M, Harmon RS (eds) Orfbrd Univ. Press, Oxford... [Pg.57]

Johnson SG, Fearey BL (1993) Spectroscopic study of thorium using continuous-wave resonance ionization mass-spectrometry with rrltraviolet ionization. Spectrochim Acta Part B 48 1065-1077 Knoll GF (1989) Radiation Detection and Measurement. J. Wiley and Sons, New York Kuss HM (1992) Applications of microwave digestion technique for elemental analyses. Fresenins J Anal Chem 343 788-793... [Pg.57]

As SFC provides gaseous sample introduction to the plasma and thus near-100 % analyte transport efficiency, coupling SFC with plasma mass spectrometry offers the potential of a highly sensitive, element-selective chromatographic detector for many elements. Helium high-efficiency microwave-induced plasma has been proposed as an element-selective detector for both pSFC and cSFC [467,468] easy hyphenation of pSFC to AED has been reported [213]. [Pg.488]

E.H. Evans, J.J. Giglio, T.M. Castillano and J.A. Caruso, Inductively Coupled and Microwave Induced Plasma Sources for Mass Spectrometry, The Royal Society of Chemistry, Cambridge (1995). [Pg.678]


See other pages where Microwave spectrometry is mentioned: [Pg.3]    [Pg.585]    [Pg.322]    [Pg.165]    [Pg.1683]    [Pg.61]    [Pg.3]    [Pg.585]    [Pg.322]    [Pg.165]    [Pg.1683]    [Pg.61]    [Pg.191]    [Pg.527]    [Pg.630]    [Pg.774]    [Pg.873]    [Pg.14]    [Pg.189]    [Pg.451]    [Pg.7]    [Pg.249]    [Pg.451]    [Pg.79]    [Pg.25]    [Pg.26]    [Pg.377]    [Pg.102]    [Pg.211]    [Pg.585]    [Pg.614]   
See also in sourсe #XX -- [ Pg.213 ]

See also in sourсe #XX -- [ Pg.205 , Pg.270 ]




SEARCH



Atomic absorption spectrometry microwave dissolution

Atomic emission spectrometry microwave-induced

Guided microwave spectrometry

Helium microwave-induced plasma mass spectrometry

Microwave plasma mass spectrometry

Microwave-induced plasma atomic emission spectrometry

Microwave-induced plasma mass spectrometry

Microwave-induced plasma optical emission spectrometry