Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Methods of control

In the field of radiation methods of control, development work was performed in order to create the X-ray detectors with a low content of silver. X-ray TV systems with improved performance for automatic interpretation of the X-ray TV images, portable radiometers and dosimeters, creation of portable equipment for radioscopy of the welded joints of pipelines, etc. [Pg.969]

In other words, if we look at any phase-space volume element, the rate of incoming state points should equal the rate of outflow. This requires that be a fiinction of the constants of the motion, and especially Q=Q i). Equilibrium also implies d(/)/dt = 0 for any /. The extension of the above equations to nonequilibriiim ensembles requires a consideration of entropy production, the method of controlling energy dissipation (diennostatting) and the consequent non-Liouville nature of the time evolution [35]. [Pg.2249]

The one-carbon fragment is ethyl formate. This reaction is important as a method of control since it occurs only on one side of the carbonyl group that is it is regioselective. The reason is that this product can itself enohse in... [Pg.32]

Galvanic corrosion can be controlled by the use of sacrificial anodes. This is a common method of controlling corrosion in heat exchangers with Admiralty tube bundles and carbon steel tube sheets and channel heads. The anodes are bolted direcdy to the steel and protect a limited area around the anode. Proper placement of sacrificial anodes is a precise science. [Pg.267]

Absorptive distillation, involving the addition of water to the upper section of a column in the whiskey distillation system, is a method of controlling the level of heavier components in a product. [Pg.85]

Air-Flow Control Process operating reqmrements and weather conditions are considered in determining the method of controlling air flow. The most common methods include simple on-off control, on-off step control (in the case of multiple-driver units), two-speed-motor control, variable-speed drivers, controllable fan pitch, manually or automatically adjustable louvers, and air recirculation. [Pg.1080]

In report separately discuss the peculiarities of determination of the anion composition of the solid solutions, that conditioned by ability of diphosphate anion to destruction in water solutions. In given concrete case by most acceptable method of control of the diphosphate anion in the hydrated solid solutions is a traditional method of the quantitative chromatography on the paper. Methodical ways which providing of minimum destruction of the diphosphate anion in the time of preparation of the model to analysis (translation in soluble condition) and during quantitative determination of the P.,0, anion are considered. [Pg.182]

In most cases, artificial destratification is carried out throughout the summer. However, work in the Lund Tubes in Blelham Tarn suggests that intermittent destratification could provide further enhancement to this method of control by creating an unstable environment. This instability causes disruption of growth patterns of the algal community and, consequently, no species becomes dominant. [Pg.38]

At the central platform, water and hydrocarbon liquids are first removed in knockout drums. Then saturated natural gas, free of any liquid droplets, enters the twin expanders. The gas is cooled below its dewpoint, allowing heavy hydrocarbon components and water vapor to condense in the discharge stream. Turboexpanders were chosen for two main reasons They are more compact than competing methods of controlling the dewpoint and their operating costs are typically lower than those of many alternatives. [Pg.451]

One of the methods of controlling air pollution mentioned in the previous chapter was pollution removal. For pollution removal to be accomplished, the polluted carrier gas must pass through a control device or system, which collects or destroys the pollutant and releases the cleaned carrier gas to the atmosphere. The control device or system selected must be specific for the pollutant of concern. If the pollutant is an aerosol, the device used will, in most cases, be different from the one used for a gaseous pollutant. If the aerosol is a dry solid, a different device must be used than for liquid droplets. [Pg.460]

Control of stationary sources of air pollution requires the application of either the control concepts mentioned in Chapter 28 of the control devices mentioned in Chapter 29. In some cases, more than one system or device must be used to achieve satisfactory control. The three general methods of control are (1) process change to a less polluting process or to a lowered emission from the existing process through modification of the operation,... [Pg.489]

Another form current-mode control is called hysteretic current-mode control. Here both the peak and the valley currents are controlled. This is obviously better for continuous-mode forward for boost converters. It is somewhat complicated to set-up, but it does offer very fast response times. It is not a very common method of control and its frequency varies. [Pg.74]

Quasi-resonant converters are a separate class of switching power supplies that tune the ac power waveforms to reduce or eliminate the switching loss within the supply. This is done by placing resonant tank circuits within the ac current paths to create pseudo-sinusoidal voltage or current waveforms. Because the tank circuits have one resonant frequency, the method of control needs to be modified to a variable frequency control where the resonant period is fixed and the control varies the period of the non-resonant period. The quasi-resonant converters usually operate in the 300 kHz to 2 MHz frequency range. [Pg.151]

The method of control of the ZVS QR converter is inverse from the ZCS. At light loads, the control frequency is high, thus performing many off-times. When the load is heavy, the number of off-times decreases. So its control relationship is... [Pg.155]

AVe in this case can be the peak-to-peak voltage of the oscillator ramp if the method of control is voltage-mode, or the maximum peak voltage representing the primary current within the current-mode method of control. The gain can be converted into decibels, which is shown in Equation B.7. [Pg.203]

Power Supply Cookbook, Second Edition has been updated with the latest advances in the field of efficient power conversion. Efficiencies of between 80 to 95 percent are now possible using these new techniques. The major losses within the switching power supply and the modern techniques to reduce them are discussed at length. These include synchronous rectification, lossless snubbers, and active clamps. The information on methods of control, noise control, and optimum printed circuit board layout has also been updated. [Pg.276]

Either acid or base catalysis may be employed. Alkaline catalysts such as caustic soda or sodium methoxide give more rapid alcoholysis. With alkaline catalysts, increasing catalyst concentration, usually less than 1% in the case of sodium methoxide, will result in decreasing residual acetate content and this phenomenon is used as a method of controlling the degree of alcoholysis. Variations in reaction time provide only a secondary means of controlling the reaction. At 60°C the reaction may takes less than an hour but at 20°C complete hydrolysis may take up to 8 hours. [Pg.390]

The power consumed to operate a wet electrostatic precipitator is much less than that required by most other methods of control. There are four areas in which power is consumed (1) electrostatic power, (2) fan power, (3) insulator heating power, and (4) pump power. The total electrostatic power input required for operation is 0.8 to 1.0 kW/1,000 ft of collection area. A comparable piece of equipment is a venturi scrubber with 50-in.wg pressure drop. The power required for this installation would be 6 to 7 kW/1,000 cfm. This would mean that approximately seven times the power would be needed to achieve the same amount of cleaning with a venturi scrubber as opposed to using a precipitator. [Pg.432]

The lime feeding system may be controlled by an instrumentation system integrating both plant flow and pH of the wastewater after lime addition. However, it should be recognized that pH probes require daily maintenance in this application to monitor the pH accurately. Deposits tend to build up on the probe and necessitate frequent maintenance. The low pH lime treatment systems (pH 9.5 to 10.0) can be more readily adapted to this method of control than high-lime treatment systems (pH 11.0 or greater) because less maintenance of the pH equipment is required. In a close-loop pH-flow control system, milk of lime is prepared on a batch basis and... [Pg.102]

The most frequent method of controlling reaction temperature employs a solvent with a suitable boiling point in conjunction with a reflux condenser. Under these circumstances, heating can be done with a steam bath, hot plate, or heating mantle. [Pg.170]

Determination of the drug substance is expected to be enantioselective, and this may be achieved by including a chiral assay in the specification or an achiral assay together with appropriate methods of controlling the enantiomeric impurity. For a drug product where racemization does not occur during manufacture or storage, an achiral assay may suffice. If racemization does happen, then a chiral assay should be used or an achiral method combined with a validated procedure to control the presence of the other enantiomer. [Pg.335]

Outlet Damper mth Constant Fan Speed. The system resistance is varied with this damper. The volume of gas delivered from the fan is changed as a function of the movement of the damper. It is low in first cost and simple to operate but does require more horsepower than other methods of control. [Pg.552]

Figure 12-135B. Comparison of efficiencies of five principal methods of controlling fan output. (Used by permission The Howden Fan Company.)... Figure 12-135B. Comparison of efficiencies of five principal methods of controlling fan output. (Used by permission The Howden Fan Company.)...
A hardened-steel or hardwood shoe bearing against the back of the chain is another method of controlling chain tension. The method is satisfactory for small horsepower drives operating on fixed centers at slow or moderate speed with ample lubrication. [Pg.449]

The driller s method of controlling a kick is accomplished in two main steps ... [Pg.1107]


See other pages where Methods of control is mentioned: [Pg.2322]    [Pg.443]    [Pg.104]    [Pg.458]    [Pg.334]    [Pg.184]    [Pg.288]    [Pg.354]    [Pg.228]    [Pg.492]    [Pg.930]    [Pg.2335]    [Pg.89]    [Pg.43]    [Pg.51]    [Pg.75]    [Pg.9]    [Pg.298]    [Pg.511]    [Pg.1442]    [Pg.269]    [Pg.158]    [Pg.365]    [Pg.195]    [Pg.1302]    [Pg.48]   


SEARCH



Alternative methods of insect control

Analytical methods and quality control of pesticides in developing countries

Application of Controlled-Potential Methods

Brief Overview of Current Control Methods

Control methods

Control of Hazardous Energy—Lockout/Tagout and Alternative Methods

Control of product gas temperature method

Empirical Methods of Controller Specification

Essential Oils Analytical Methods to Control the Quality of Perfumes

Method for quality control of textile electrodes

Methods of pest control

Pain ladder method of controlling approach

Procedure of Cell-Impedance-Controlled Current Transients with Kinetic Monte Carlo Method

Searching Environmentally Benign Methods for Pest Control Reflections of a Synthetic Chemist

Selection of Fire Control and Suppression Methods

Steps in the Selection of a DDA or Other Flame Propagation Control Method

The method of controlled evacuation

© 2024 chempedia.info