Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Low molecular mass

Low molecular mass enol esters (e.g. acetates H.O. House, 1965) or enol ethers (e.g. silyl ethers H.O. House, 1969) of ketones can be synthesized regioselectively and/or separated by distillation. Treatment with lithium alkyls converts them into the corresponding lithi-... [Pg.57]

Fundamentally, introduction of a gaseous sample is the easiest option for ICP/MS because all of the sample can be passed efficiently along the inlet tube and into the center of the flame. Unfortunately, gases are mainly confined to low-molecular-mass compounds, and many of the samples that need to be examined cannot be vaporized easily. Nevertheless, there are some key analyses that are carried out in this fashion the major one i.s the generation of volatile hydrides. Other methods for volatiles are discussed below. An important method of analysis uses lasers to vaporize nonvolatile samples such as bone or ceramics. With a laser, ablated (vaporized) sample material is swept into the plasma flame before it can condense out again. Similarly, electrically heated filaments or ovens are also used to volatilize solids, the vapor of which is then swept by argon makeup gas into the plasma torch. However, for convenience, the methods of introducing solid samples are discussed fully in Part C (Chapter 17). [Pg.98]

Apart from ES and APCI being excellent ion sources/inlet systems for polar, thermally unstable, high-molecular-mass substances eluting from an LC or a CE column, they can also be used for stand-alone solutions of substances of high to low molecular mass. In these cases, a solution of the sample substance is placed in a short length of capillary tubing and is then sprayed from there into the mass spectrometer. [Pg.284]

Until 1981, mass spectrometry was limited, generally, to the analysis of volatile, relatively low-molecular-mass samples and was difficult to apply to nonvolatile peptides and proteins without first cutting them chemically into smaller volatile segments. During the past decade, the situation has changed radically with the advent of new ionization techniques and the development of tandem mass spectrometry. Now, the mass spectrometer has a well-deserved place in any laboratory interested in the analysis of peptides and proteins. [Pg.287]

Almost any type of analyzer could be used to separate isotopes, so their ratios of abundances can be measured. In practice, the type of analyzer employed will depend on the resolution needed to differentiate among a range of isotopes. When the isotopes are locked into multielement ions, it becomes difficult to separate all of the possible isotopes. For example, an ion of composition CgHijOj will actually consist of many compositions if all of the isotopes ( C, C, H, H, 0, O, and 0) are considered. To resolve all of these isotopic compositions before measurement of their abundances is difficult. For low-molecular-mass ions (HjO, COj) or for atomic ions (Ca, Cl), the problems are not so severe. Therefore, most accurate isotope ratio measurements are made on low-molecular-mass species, and resolution of these even with simple analyzers is not difficult. The most widely used analyzers are based on magnets, quadrupoles, ion traps, and time-of-flight instruments. [Pg.365]

Hydrochloric acid [7647-01-0], which is formed as by-product from unreacted chloroacetic acid, is fed into an absorption column. After the addition of acid and alcohol is complete, the mixture is heated at reflux for 6—8 h, whereby the intermediate malonic acid ester monoamide is hydroly2ed to a dialkyl malonate. The pure ester is obtained from the mixture of cmde esters by extraction with ben2ene [71-43-2], toluene [108-88-3], or xylene [1330-20-7]. The organic phase is washed with dilute sodium hydroxide [1310-73-2] to remove small amounts of the monoester. The diester is then separated from solvent by distillation at atmospheric pressure, and the malonic ester obtained by redistillation under vacuum as a colorless Hquid with a minimum assay of 99%. The aqueous phase contains considerable amounts of mineral acid and salts and must be treated before being fed to the waste treatment plant. The process is suitable for both the dimethyl and diethyl esters. The yield based on sodium chloroacetate is 75—85%. Various low molecular mass hydrocarbons, some of them partially chlorinated, are formed as by-products. Although a relatively simple plant is sufficient for the reaction itself, a si2eable investment is required for treatment of the wastewater and exhaust gas. [Pg.467]

Polyamide-imides may also be produced by reacting a diacid chloride with an excess of diamine to produce a low molecular mass polyamide with amine end groups. This may then be chain extended by reaction with pyromellitic dianhydride to produce imide linkages. Alternatively the dianhydride, diamine and diacid chloride may be reacted all together. [Pg.525]

Whereas cellulose films are biodegradable, that is they are readily attacked by bacteria, films and packaging from synthetic polymers are normally attacked at a very low rate. This has led to methods of degrading polymers to a sufficiently low molecular mass (typically about 10000) which are then accessible to biodegradation. [Pg.881]

FIGURE 2.1 I Separation of a low molecular mass sample mixture on Superdex peptide HR 10/ 30 in 20 min. (Reproduced with permission from Amersham Pharmacia Biotech.)... [Pg.55]

Another interesting application of LC-LC is the determination of low-molecular-mass carbonyl compounds in air. Carbonyl compounds, such as aldehydes and ketones, are now being given more and more attention, both as pollutants and as... [Pg.353]

Figure 13,12 Illusti ation of the clean-up method, showing the analysis of an air sample (a) with and (b) without column switching. Details of the analytical conditions are given in the text. Reprinted from Journal of Chromatography, A 697, R R. Kootsti a and H. A. Herbold, Automated solid-phase exti action and coupled-column reversed-phase liquid cltromatogra-phy for the trace-level determination of low-molecular-mass carbonyl compounds in ak , pp. 203-211, copyright 1995, with permission from Elsevier Science. Figure 13,12 Illusti ation of the clean-up method, showing the analysis of an air sample (a) with and (b) without column switching. Details of the analytical conditions are given in the text. Reprinted from Journal of Chromatography, A 697, R R. Kootsti a and H. A. Herbold, Automated solid-phase exti action and coupled-column reversed-phase liquid cltromatogra-phy for the trace-level determination of low-molecular-mass carbonyl compounds in ak , pp. 203-211, copyright 1995, with permission from Elsevier Science.
P. R. Kootstr-a and H. A. Herbold, Automated solid-phase extraction and coupled-column reversed-phase liquid cliromatogr aphy for the trace-level determination of low-molecular-mass carbonyl compounds in ak , 7. Chromatogr. 697 203-211 (1995). [Pg.373]

In contrast to low molecular mass materials, polymeric emitters possess the advantage that they can be easily worked into transparent films with a low degree... [Pg.35]

It is an intensely reactive and hygoscopic yellow-brown substance (m.p. 75-78°C) its volatility suggests a low molecular mass Mossbauer spectra indicate 6-coordinate gold while the Raman spectrum is interpreted in terms of cw-bridged octahedral units. In the gas phase at 170°C, it comprises dimers and trimers [29] (electron diffraction). [Pg.282]

Phospholipases. Table 1 Classification of low molecular mass phospholipase A2 isozymes that use catalytic His... [Pg.967]

The classical PTPs can be subdivided into receptorlike PTPs and nonreceptor, cytosolic PTPs. The second category of PTPs are broadly defined as dual specificity phosphatases (DSPs), which dephosphorylate pSer/ pThr as well as pTyr. MAP kinase phosphatases (MKPs) ( MAP kinase cascades) and PTEN are examples of DSP family members. Remarkably, PTEN also has lipid phosphatase activity that is specific for phosphatidylinositol-3,4,5-trisphosphate generated in response to the actions of PI3K. Finally, the class of low molecular mass (LM-) PTPs and that of CDC25 PTPs accomplish the cells repertoire of PTPs (Fig. 3). [Pg.1014]

Acid- and alkaline phosphatases act on a variety of mono- and multiple phosphate carrying low molecular mass molecules. In addition, they hydrolyze many, but not all, phosphoproteins. They are in use for decades to easily screen for diseases, however, somewhat unspe-cifially. For instance, acid phosphatase is used as biomarker for prostate cancer, and alkaline phosphatase to monitor bone (de-) mineralization and liver tumors. [Pg.1015]

It is known the case of i-PP, for which the copolymerization with small amounts of ethylene tends to stabilize the y form [84] for instance, by melt crystallization of a copolymer with 6% by mol of ethylene more than 80% of the crystalline phase is in the y form [85], It is also known that the obtainment of the y form by melt crystallization, is also favored for samples of low molecular mass [86, 87] and for stereoblock fractions [88]. This seems to suggest that, whenever the preferential crystallization of the y-form is observed, there is the concomitant occurrence of a reduction in the polymer of the length of the chain stretches with polypropylene head to tail constitution and isotactic configuration. [Pg.204]

On the basis of the nucleophilicity parameters B, NBs, and fi (see Table 8-2) one expects less of the homolytic product in water than in methanol. This is, however, not the case. It has been known for many decades that a very complex mixture of products is formed in the decomposition of diazonium ions, including polymeric products, the so-called diazo tars. In alcohols this is quite different. The number of products exceeds three or four only in exceptional cases, diazo tars are hardly formed. For dediazoniation in weakly alkaline aqueous solutions, there has, to the best of our knowledge, been only one detailed study (Besse et al., 1981) on the products of decomposition of 4-chlorobenzenediazonium fluoroborate in aqueous HCOf/ CO]- buffers at pH 9.00-10.30. Depending on reaction conditions, up to ten compounds of low molecular mass were identified besides the diazo tar. [Pg.201]

Low molecular mass compounds capable of forming liquid crystals have been known since the late 1880s. They did not assume commercial importance until the late 1960s, however, when their properties were exploited in the design of electronic displays. Following the development of commercial applications for liquid crystals, polymers began to be studied for their potential in this application. [Pg.156]

Fig. 17a-c. Sketches of the molecular arrangements for the smectic structure with alternating layer-to-layer tilt a conventional and chevron smectic C layering in low molecular mass mesogens b ferroelectric hilayer chevron structures for achiral side-chain polymers c antiferroelectric hilayer chevron structures for achiral side-chain polymers. Arrows indicate the macroscopic polarization in the direction of the molecular tilt... [Pg.233]

The simulation of macromolecular systems involves, in principle, the same difficulties as that of compounds of low-molecular mass, but the polymeric nature of the molecules tends to aggravate the computational problems faced by investigators of small molecules. [Pg.162]

In contrast to materials of low molecular mass, polymeric emitters possess the advantage that they can be easily worked into transparent films with a low degree of scattering. In addition, they show a higher morphological stability than that of vapor-deposited low molecular weight compounds (low tendency toward recrystallization). [Pg.171]


See other pages where Low molecular mass is mentioned: [Pg.56]    [Pg.65]    [Pg.68]    [Pg.72]    [Pg.136]    [Pg.278]    [Pg.521]    [Pg.561]    [Pg.241]    [Pg.241]    [Pg.315]    [Pg.94]    [Pg.99]    [Pg.11]    [Pg.10]    [Pg.12]    [Pg.708]    [Pg.967]    [Pg.968]    [Pg.1139]    [Pg.1496]    [Pg.186]    [Pg.212]    [Pg.210]    [Pg.14]    [Pg.33]    [Pg.33]    [Pg.370]   
See also in sourсe #XX -- [ Pg.600 ]




SEARCH



Binding of low molecular mass compounds

Low Molecular Mass GTPases

Low molecular mass LCs

Low molecular mass displacers

Low molecular mass fractions

Low molecular mass liquid crystal

Low molecular mass permeation enhancers

Low-mass

Low-molecular

Low-molecular mass compounds,

Low-molecular-mass components

Low-molecular-mass molecules

Low-molecular-mass organic acids

Low-molecular-mass organic acids LMMOAs)

Low-molecular-mass organic gelators

Low-molecular-mass substances

Molecular mass

Radical transfer reactions to low molecular mass species

© 2024 chempedia.info