Lipids sample preparation

The basic technology for the preparation of sample material is similar in all TLC preparations, irrespective of the origin of the hpid and specific preparation method for a variety of biological samples [43]. The most important factor is the solubihty of the sample. The lipid sample must be completely soluble in the dissolving solvent prior to the application and must be free from water. Either toluene or chloroform is commonly used as the solvent to dissolve hpid materials. The dissolving solvent should be nonpolar in namre and volatile at such a concentration that the hpid components in the sample are completely adsorbed throughout the entire thickness of the layer as quickly as possible. Although sample sizes as small as 1 to 10 pi can... [Pg.306]

The amoimt of lipid applied to the plate varies depending on the ease of separation of individual lipid components in the sample. Usually 25 to 50 mg of the neutral lipid sample can be applied to a 20 X 20 cm preparative plate with the silica gel G layer thickness of 0.5 mm, whereas only about 4 mg of phospholipids can be applied on these plates. [Pg.308]

An immunoassay was developed to determine the penicillinase stable isoxazolyl penicillins cloxacillin and dicloxacillin in milk by Usleber et alJ The assay detected lOpgkg" of cloxacillin and 30pgkg of dicloxacillin with recoveries of 102% and 84%, respectively. The calibration curve was prepared by fortifying skimmed milk powder (lOOgL ) with standards. Fortified samples were prepared in pasteurized milk and analyzed directly after decreaming by centrifugation. This immunoassay was performed with minimal sample preparation, probably because the extensive water solubility of the penicillins prevents problems associated with more lipid-soluble analytes. [Pg.702]

Ivermectin, a macrocyclic lactone, is also utilized to control parasites. An immunoassay was developed to determine ivermectin residues in bovine liver by Crooks etal. The sample preparation procedure was complex, involving tissue homogenization in acetonitrile, centrifugation, extraction with hexane (to remove lipids), evaporation and reconstitution in ethyl acetate, and passage through an SPE column followed... [Pg.706]

Sample preparation used to extract proteins from cells prior to analysis is an important step that can have an effect on the accuracy and reproducibility of the results. Proteins isolated from bacterial cells will have co-extracted contaminants such as lipids, polysaccharides, and nucleic acids. In addition various organic salts, buffers, detergents, surfactants, and preservatives may have been added to aid in protein extraction or to retain enzymatic or biological activity of the proteins. The presence of these extraneous materials can significantly impede or affect the reproducibility of analysis if they are not removed prior to analysis. [Pg.206]

Although ribosomal proteins are readily observed as in Figures 13.7 and 13.8 altered matrix conditions can alter the relative ionization of bacterial whole-cell compounds. A systematic analysis involving laser power/fluence and sample preparation conditions reveals that if the concentrated trifluo-roacetic acid is added and the laser power increased above optimal conditions, ionization of bacterial surface compounds can be enhanced. Figure 13.9 is the resulting 9.4 T MALDI-FTMS, seen are both the Braun s lipoprotein56,57 and the Murein lipoprotein. Both of these compounds are complex combinations of hydrocarbon lipids attached to a protein base. This is the first MALDI-FTMS observation of surface proteins desorbed directly from whole cells by influencing ionization conditions. [Pg.291]

The results for bacterial whole-cell analysis described here establish the utility of MALDI-FTMS for mass spectral analysis of whole-cell bacteria and (potentially) more complex single-celled organisms. The use of MALDI-measured accurate mass values combined with mass defect plots is rapid, accurate, and simpler in sample preparation then conventional liquid chromatographic methods for bacterial lipid analysis. Intact cell MALDI-FTMS bacterial lipid characterization complements the use of proteomics profiling by mass spectrometry because it relies on accurate mass measurements of chemical species that are not subject to posttranslational modification or proteolytic degradation. [Pg.295]

Retention of a protein or protein activity after 105,000y, 1 hr Chromatography on gel filtration columns with large pore sizes Electron microscopy—however, sample preparation may partially reconstitute membranes Decrease in solution turbidity, which may be detected by a diminution in light scattering or an enhancement in light transmission Diffusion of membrane lipids as assayed by nuclear magnetic resonance and electron spin resonance... [Pg.185]

Heptachlor and heptachlor epoxide have been measured in samples of human milk using GC/ECD and GC/MS (Mussalo-Rauhamaa et al. 1988 Polishuk et al. 1977b Ritcey et al. 1972). Sample preparation steps for milk involve homogenization with chloroform/methanol, lipid extraction with petroleum ether, hexane or acetone-hexane, clean-up by column chromatography, and elution with acetonitrile, hexane, methylene chloride, or dichloromethane-petroleum ether. Precision, accuracy, and sensitivity were not reported for most of the studies however, one study reported a sensitivity in the low-ppb range (Ritcey et al. 1972). [Pg.98]

To detect dynamic featnres of colloidal preparations, additional methods are required. Nuclear magnetic resonance spectroscopy allows a rapid, repeatable, and noninvasive measurement of the physical parameters of lipid matrices withont sample preparation (e.g., dilution of the probe) [26,27]. Decreased lipid mobility resnlts in a remarkable broadening of the signals of lipid protons, which allows the differentiation of SLN and supercooled melts. Because of the different chemical shifts, it is possible to attribute the nuclear magnetic resonance signal to particnlar molecnles or their segments. [Pg.7]

A newer approach for lipid analysis is electrospray ionization tandem mass spectrometry (ESI-MS/MS) (Welti et al., 2002). This method requires limited sample preparation and sample size to identify and quantify lipids. Fauconnier et al. (2003) used ESI-MS/MS to analyze phospholipid and galactolipid levels during aging of potato tubers. [Pg.227]

Determination of CholesteroL For meat extraction, the procedures for determining the cholesterol of extracted lipid samples were described Chao et al. (2i). For edible beef tallow extraction, the preparation of samples for cholesterol content was based on the AOAC (22) method Section 28.110. The prepared sample was then injected into a Supelco SPB-1 fused silica capillary column of 30 meters x 032 mm i.d. in a Varian Model 3700 gas chromatograph equipped with dual flame ionization detectors. The initial holdup time was 4 min at 270°C and then programmed to a temperature of 300°C at a ramp rate of 10°C/min. Helium flow rate and split ratio were 13 ml and 50 1, respectively, while the injector/detector temperature was 310°C. [Pg.121]

Diethylstilbestrol is particularly difficult to quantitate below 1.0 ppb in bovine tissues, especially in liver, which is among the last tissues to contain diethystilbestrol after cattle are withdrawn from receiving tire drug (101, 102). Interferences from tissue matrix constitute a major problem that might be due to nonspecific interference of lipids and fatty compounds (103, 104). In addition, problems with false-positive results often appear in urine analysis unless a chromatographic step such as a solid-phase extraction cleanup (105, 106) is introduced. Simple sample preparation procedures such as those based on solvent extraction and liquid-liquid partitioning do not usually give satisfactory results (107, 108). [Pg.852]

BASIC PROTOCOL I PREPARATION OF FATTY ACID METHYL ESTERS FROM LIPID SAMPLES CATALYZED WITH BORON TRIFLUORIDE IN METHANOL In this method, lipid samples are first saponified with an excess of NaOH in methanol. Liberated fatty acids are then methylated in the presence of BF3 in methanol. The resulting fatty acid methyl esters (FAMEs) are extracted with an organic solvent (isooctane or hexane), and then sealed in GC sample vials for analysis. Because of the acidic condition and high temperature (100°C) used in the process, isomerization will occur to those fatty acids containing conjugated dienes, such as in dairy and ruminant meat products, that contain conjugated linoleic acids (CLA). If CLA isomers are of interest in the analysis, Basic Protocol 2 or the Alternate Protocol should be used instead. Based on experience, this method underestimates the amount of the naturally occurring cis-9, trans-11 CLA isomer by -10%. The formulas for the chemical reactions involved in this protocol are outlined in Equation D1.2.1 Saponification RCOO-R + NaOH, RCOO-Na + R -OH v 100°C DC Esterification RCOO-Na + CH,OH r 3 v RCOO-CH, + NaOH ioo°c ... [Pg.438]

PREPARATION OF FATTY ACID METHYL ESTERS FROM LIPID SAMPLES CATALYZED WITH SODIUM METHOXIDE IN METHANOL... [Pg.440]


See other pages where Lipids sample preparation is mentioned: [Pg.285]    [Pg.285]    [Pg.149]    [Pg.169]    [Pg.194]    [Pg.307]    [Pg.312]    [Pg.683]    [Pg.693]    [Pg.697]    [Pg.321]    [Pg.279]    [Pg.216]    [Pg.72]    [Pg.323]    [Pg.279]    [Pg.781]    [Pg.113]    [Pg.31]    [Pg.100]    [Pg.137]    [Pg.98]    [Pg.103]    [Pg.640]    [Pg.8]    [Pg.18]    [Pg.23]    [Pg.411]    [Pg.64]    [Pg.70]    [Pg.577]    [Pg.179]    [Pg.37]    [Pg.437]    [Pg.438]   
See also in sourсe #XX -- [ Pg.306 , Pg.307 ]

See also in sourсe #XX -- [ Pg.689 , Pg.690 ]

See also in sourсe #XX -- [ Pg.218 , Pg.219 ]