Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Insulator service

If the distribution network consists of pipes with screwed rubber sockets and only the service pipes are of steel, these can be protected with zinc or magnesium anodes. This requires an insulating service clip near the insulating connection. It is usually sufficient just to insulate the stirrup of the service clip since the rubber seal of the service pipe acts as an insulator. In the United Kingdom, the protection of numerous service pipes has been proved with magnesium anodes [31]. [Pg.285]

In still another development, greases are used in insulator service which have been developed for high-voltage insulation purposes. They are based on thickened parafBns, petrolatum, and ceresin. [Pg.217]

Barriers and controls (4) All relief valves are either isolated from personnel by distance or are contained inside an insulated service panel. [Pg.111]

M S is also exploring how it can use its environment-friendly credentials to do more business, building on the sueeess of M S Energy. A new home insulation service has already been launehed. Writing in the FT last year. Sir Stuart said the greening of the home market would be worth billions in the years to come. People trust the M S brand in that marketplaee, Barry says. [Pg.155]

Yang HE, Chen U, He F et al (2012) NM Cable insulation service fife time prediction using materials... [Pg.150]

The market for composite insulators is growing steadily. Composite designs generally employ a fibreglass rod or hollow core for mechanical strength, with an outer housing made from either silicone mbber, EPDM or EPR. Insulator service life can be affected by electrical, mechanical and environmental stresses. One of the biggest... [Pg.43]

One further use of Fiberglas in vacuum insulation service is its application between flexible skins with the Fiberglas itself supporting the load of atmospheric pressure, keeping the skins separated. Figure 10 is a load-density curve... [Pg.150]

As a tme thermoplastic, FEP copolymer can be melt-processed by extmsion and compression, injection, and blow molding. Films can be heat-bonded and sealed, vacuum-formed, and laminated to various substrates. Chemical inertness and corrosion resistance make FEP highly suitable for chemical services its dielectric and insulating properties favor it for electrical and electronic service and its low frictional properties, mechanical toughness, thermal stabiUty, and nonstick quaUty make it highly suitable for bearings and seals, high temperature components, and nonstick surfaces. [Pg.358]

Electrica.1 Properties. Because of excellent electrical properties, FEP is a valuable and versatile electrical insulator. Within the recommended service temperature range, PTFE and EEP have identical properties as electrical insulators. Volume resistivity, which is >10 H/cm, remains unchanged even after prolonged soaking in water surface resistivity is >10 H/sq. [Pg.361]

Because the heat distortion temperature of cured epoxy resins (qv) increases with the functionality of the curing agents, pyromellitic dianhydride is used to cross-link epoxy resins for elevated temperature service. The dianhydride may be added as a dispersion of micropulverized powder in liquid epoxy resin or as a glycol adduct (158). Such epoxies may be used as an insulating layer in printed circuit boards to improve heat resistance (159). Other uses include inhibition of corrosion (160,161), hot melt traffic paints (162), azo pigments (163), adhesives (164), and photoresist compounds (165). [Pg.500]

Lugs are an improvement of the ear type by the addition of an element to provide lateral stiffening which also serves to improve load-carrying capacity and lateral strength. In high temperature services, unless heavily insulated, lugs are susceptible to distortion. [Pg.60]

PVC—nitrile mbber permanent plasticization of PVC, improved processibihty wire and cable insulation, food contact service 141,317,318... [Pg.422]

Insulating Brick ASTM classifies insulating firebrick under C155 by group. The group number corresponds to the service temperature divided by 100 (Table 13). For example, group 16 corresponds to a test temperature of ca 1600°F (871°C). [Pg.33]

Equipment Costs. Equipment costs include the purchased cost of process and materials handling equipment, storage faciUties, waste treatment equipment, stmctures, and site service faciUties. Installation costs such as insulation, piping, painting and finishing, foundations, process stmctures, instmmentation, and electrical service connections are estimated or factored separately. Actual quoted prices from suppHers are the best data, but these are not usually available when estimates are made. The quick, inexpensive cost estimates are based largely on personal cost files, internal company cost data, or pubUshed cost correlations. [Pg.441]

However, conductive elastomers have only ca <10 of the conductivity of soHd metals. Also, the contact resistance of elastomers changes with time when they are compressed. Therefore, elastomers are not used where significant currents must be carried or when low or stable resistance is required. Typical apphcations, which require a high density of contacts and easy disassembly for servicing, include connection between Hquid crystal display panels (see Liquid crystals) and between printed circuit boards in watches. Another type of elastomeric contact has a nonconducting silicone mbber core around which is wrapped metalized contacts that are separated from each other by insulating areas (25). A newer material has closely spaced strings of small spherical metal particles in contact, or fine soHd wires, which are oriented in the elastomer so that electrical conduction occurs only in the Z direction (26). [Pg.31]

With external insulation, the metal temperature is taken as the fluid temperature unless service data, tests, or calculations justify lower values. For internally insulated pipe, the design metal temperature shall be calculated or obtained from tests. [Pg.980]

Electrode insulators must also be designed for a particular service. The properties of the dust or mist and gas determine their design as well as the physical details of the installation. Conducting mists require specif lowances such as oil seals, energized shielding cups, or air bleeds. With saturated gas, steam coils are frequently used to prevent condensation on the electrodes. [Pg.1616]

Electrical insulation Thermal properties Service temperature, F Fair Good Very good Good Fair to good... [Pg.2473]

In LT motors, a standard test finger as shown in Figure 11.7 is used, connected by an incandescent lamp to one pole of a supply of at least 40 V, the other pole of the supply being connected to the parts intended to be live in normal service. All parts must be connected electrically. The lamp should not glow when an attempt is made to touch the bare live parts or insufficiently insulated parts. Insufficiently insulated parts may be covered with a metal foil connected to tho.se parts that are live in normal service. Conducting parts covered with varnish or enamel only or protected by oxidation or by a similar process may be considered as insufficiently insulated. In HT motors, the clearance is verified with the minimum clearance required to withstand the dielectric test as in Section 11.4.8,... [Pg.264]

The purpose of this test is to check for proper insulation of all the insulated live parts and components and to ensure protection of a human body against electrical shocks while the eqtiipment is energized and is in operation. The test detects weak insulation, if any, and this must be rectified before putting the equipment into service. [Pg.435]

These are heat- and flameproof cables suitable for high fire risk zones. In severe fire conditions, when the outer protection and insulation have been destroyed, these cables would still maintain continuity of essential services. [Pg.533]


See other pages where Insulator service is mentioned: [Pg.34]    [Pg.121]    [Pg.299]    [Pg.503]    [Pg.329]    [Pg.459]    [Pg.523]    [Pg.70]    [Pg.79]    [Pg.66]    [Pg.332]    [Pg.312]    [Pg.333]    [Pg.545]    [Pg.336]    [Pg.46]    [Pg.59]    [Pg.125]    [Pg.226]    [Pg.273]    [Pg.441]    [Pg.779]    [Pg.978]    [Pg.1099]    [Pg.617]    [Pg.841]   
See also in sourсe #XX -- [ Pg.217 ]