Inspection level types

The setup function in automated inspection corresponds to configuring the system for the task. Several environmental factors affect the setup function. In a machine vision system, lighting factors such as illumination levels, type of illumination, reflectivity, and contrast affect performance. Most vision systems are quite sensitive to these variables. In many cases, the automated system has failed because... [Pg.1901]

Select the inspection level as specified. If the inspection level is unspecified, normal inspection level II should be used. Some companies use past quality history as a guideline for selecting the inspection level. For example, if the supplier has mostly submitted good lots in the past, level I (reduced inspection) is used. Level III (tightened inspection) is used if lots have been mostly bad. Special inspection levels 5-1 through 5-4 may also be used for expensive as well as destructive-type inspections or for parts made with repetitive-type processes. [Pg.435]

Introducing the Selenium for gammagraphic weld inspection at significantly improved quality levels of the radiographs we have also designed an exposure unit for Selenium. This unit is fuUy compatible with both models, M6 and Ml8. Different from the exposure units for iridium, which are Type B(U) containers, the Source Projector M-SE for Selenium is a Type A container with a maximum loading of 3 TBq (80Ci) Selenium. [Pg.427]

The method was applied for determination of the quality of the detection media on test pieces following the type testing of the European standard [4] in order to check the validity of the method. The other application was the determination of the visibility in dependance of the variations of the inspection parameters (application of the detection medium, magnetization, inclination, viewing conditions) in a range which may appear in the practical inspections. The results leads to conclusions on the visibility level which is a measure of the probability of recognition for the indication that means of the reliability of the method. [Pg.669]

A routine inspection of the tube bundle during a plant outage revealed fine cracks of the type shown in Fig. 9.11. Scattered longitudinal cracks were observed along the lengths of most tubes. The external surface was covered with a thin film of black copper oxide and deposits. The bundle had been exposed to ammonia levels that produced 14 ppm of ammonia in the accumulated condensate. [Pg.212]

Mobile sources include railroad locomotives, marine vessels, aircraft, and automotive vehicles. Over the past 100 years, we have gained much experience in regulating smoke and odor emission from locomotives and marine craft. Methods of combustion equipment improvement, firefighter training, and smoke inspection for these purposes are well documented. This type of control is best at the local level. [Pg.423]

In the case of a latent human error the consequences of the error may only become apparent after a period of time when the condition caused by the error combines with other errors or particular operational conditions. Two types of latent error can be distinguished. One category originates at the operational level and leads to some required system function being degraded or unavailable. Maintenance and inspection operations are a frequent source of this type of latent failure. [Pg.40]

Apart from bottom blowdown valves (main BD valve), other types of valves are often employed. Blowdown valves also can be used to control high water levels, drain the boiler for cleaning or inspection purposes, and maintain chemical concentrations and water chemistry below maximum permitted levels. [Pg.74]

It is important that the tube surfaces be kept clean to avoid the initiation of corrosion. Regular waterside inspections and, if necessary, chemical cleaning of high-pressure equipment is recommended. The level of chloride that may be tolerated in such boilers during steady operation depends on the type of treatment employed. Where all-volatile alkaline treatments (AVT) are used, then the chloride levels should be lower than where nonvolatile alkalis (NVAT), such as sodium hydroxide and sodium phosphate, are used. The value may vary, depending on whether the boiler is coal-fired or oil-fired. [Pg.589]

Compliance monitoring is used to determine a handler s level of compliance with RCRA s regulatory requirements. The primary method of collecting compliance monitoring data is through an inspection. Either U.S. EPA or an authorized state may lead inspections. Inspections must be conducted annually at all federal- or state-operated facilities and at least once every two years at each TSDF. The six types of inspections conducted under the RCRA program are2... [Pg.465]


See other pages where Inspection level types is mentioned: [Pg.299]    [Pg.483]    [Pg.418]    [Pg.999]    [Pg.1001]    [Pg.1041]    [Pg.390]    [Pg.424]    [Pg.180]    [Pg.79]    [Pg.280]    [Pg.85]    [Pg.132]    [Pg.85]    [Pg.198]    [Pg.300]    [Pg.41]    [Pg.301]    [Pg.414]    [Pg.259]    [Pg.311]    [Pg.400]    [Pg.323]    [Pg.347]    [Pg.90]    [Pg.192]    [Pg.151]    [Pg.132]    [Pg.289]    [Pg.202]    [Pg.503]    [Pg.260]    [Pg.135]    [Pg.204]    [Pg.390]    [Pg.180]    [Pg.33]    [Pg.10]    [Pg.271]    [Pg.231]   
See also in sourсe #XX -- [ Pg.38 ]