Influent concentrations

Compounds Maximum solubiUty in water, g/L Influent concentration, mg/L Adsorption capacity, kg/m ... [Pg.227]

E>/m = capacity per unit weight of carbon at the influent concentration W = weight of liquid used in the isotherm test = influent concentration... [Pg.305]

The MTZ is that length of the adsorbent bed where the adsorbate concentration in the liquid varies from the influent concentration to zero or the specification value. At the same contact time, the single fixed-bed system at the higher LV stays onstream about 15 percent longer. [Pg.308]

If your facilrty has several pieces of equipment performing a similar service, you may combine the reporting for such equipment on a single line. It is not necessary to enter four lines of data to cover four scrubber units, for example, if all four are treating wastes of similar character (e.g., sulfuric acid mist emissions), have similar influent concentrations, and have similar removal efficiencies. If, however, any of these parameters differ from one unit to the next, each scrubber must be listed separately. [Pg.47]

Enter the appropriate code for the influent concentration (in column Cl for the first treatment step in the sequence. Leave this item blank for the rest of the treatment steps in the sequence. [Pg.49]

Estimation of Treatment System Efficiencies and Influent Concentrations... [Pg.84]

Air Treatment Systems. Fabric filters and cyclone collectors are considered to be mechanical separation systems the treatment code for these systems is A06. The treatment code for wet scrubbers is A03. Information on each air treatment system must be entered individually in Section 7. The cyclone collector and fabric filter on the lead oxide mill exhaust are sequential treatment systems, because they treat the same wastestream in sequence. Therefore, sequential treatment must be indicated for both systems in column D of Section 7. You are required to indicate the influent concentration only to... [Pg.84]

In Section 7, columns C and E you must Indicate the range of influent concentration and treatment efficiency, respectively, lor each treatment system listed. The facility must estimate the efficiency and influent concentration of each air omission treatment system, as the stack test program did not determine influent concentrations. The facility has manufacturers data on the efficiency of each treatment system and should use this information along with effluent concentration data to estimate the influent concentrations. The efficiency estimates for air treatment systems are not based on operating data this must be indicated in column F of Section 7. [Pg.85]

An electrodialysis cell has the following dimensions (110 cm X 60 cm x 0.04 cm (thickness), and is used to treat water with a throughput velocity of 10 cm/sec. The product concentration is 0.0092 eq/Liter. The cell current efficiency is 0.892. Resistance across the cell is 0.205 ohm. The influent concentration is 125 mg/Liter of NaCl. Calculate the following (a) cell current, (b) cell power output, (c) the cell voltage, and (d) the energy consumption per equivalent of product transferred. [Pg.370]

This drug has proved to be very recalcitrant, as it by-passes sewage treatment. Common WWTP influent concentrations are in the order of magnitude of several hundreds of nanograms per liter [5, 8, 13, 19, 20]. [Pg.202]

Figure 5.12 Sorption breakthrough curves - effect of flow rate of breakthrough capacity (C0 = influent concentration C = effluent concentration). Figure 5.12 Sorption breakthrough curves - effect of flow rate of breakthrough capacity (C0 = influent concentration C = effluent concentration).
Pollutant Parameter Influent Concentration (mg/L) Effluent Concentration (mg/L)... [Pg.283]

Parameters Influent Concentrations Effluent Concentrations Total Removal (%)... [Pg.582]

A stripper operating at a high pressure drop will require a smaller volume than a similar stripper at a lower pressure drop. This reduces the capital cost for the tower, but increases the blower cost. Towers designed and built to operate at a low pressure drop have the flexibility to increase the gas flow rate and hence the air/water ratio, should the future influent concentration increase or the effluent limitation decrease. Towers designed for high pressure drops do not have this flexibility in operation and would need to decrease the liquid loading to increase the air/water ratio. [Pg.724]

Cyclic volatile methyl siloxane) D5 Nene and Great Ouse Rivers Surface water (England) - Influent dry weather flow - WWTP influent concentration - Effluent discharges flow [54]... [Pg.40]

Table 4 Summary of FM influent concentrations to wastewater treatment... [Pg.97]

With given flow Q and influent concentrations CAi and Cs and the required efficiency s the reactor volume and ozone consumption can be calculated from this equation. [Pg.260]

The time effect on concentration is an important consideration of process design. In treatment of most manufacturing or municipal wastes, the concentration of contaminants is usually relatively high and reasonably uniform over time (or at least predictable). At remediation sites, the concentrations tend to vary with time and not be as predictable. Certain treatment processes are more efficient at minimum concentrations and others function best at higher concentrations. When influent concentrations vary significantly with time, the effectiveness of the treatment system may vary. One system design may not be adequate for a site from start to finish. [Pg.345]

Microorganism Influent Concentration - mass/ volume- influent... [Pg.200]

The interval observer was finally tested on-line in a series of experimental runs conducted over a 35 days period in the anaerobic fixed bed reactor pilot plant. Parameters used are listed in Table 4. For the experimental implementation of the observer the influent concentrations were considered unknown and only a known boundary region was supplied to the interval observer. Figures 50 to 52 depict the corresponding bounded intervals for S, S2 and Z , respectively. [Pg.155]


See other pages where Influent concentrations is mentioned: [Pg.378]    [Pg.383]    [Pg.383]    [Pg.386]    [Pg.180]    [Pg.304]    [Pg.48]    [Pg.74]    [Pg.75]    [Pg.78]    [Pg.89]    [Pg.201]    [Pg.16]    [Pg.146]    [Pg.302]    [Pg.726]    [Pg.1043]    [Pg.1044]    [Pg.252]    [Pg.197]    [Pg.219]    [Pg.92]    [Pg.96]    [Pg.100]    [Pg.110]    [Pg.111]    [Pg.689]    [Pg.696]    [Pg.146]   