Inductively coupled plasma method

Dorn, S.B. Skelly Frame, E.M. Development of a high-performance liquid chromatographic-inductively coupled plasma method for speciation and quantification of silicones from silanols to polysiloxanes. Analyst 1994, II9, 1687-1694. [Pg.523]

Inductive Coupled Plasma - Method 11 (Used for all Types of Phosphate Fertilizers)... [Pg.1227]

Inductively Coupled Plasma Methods and Electrothermal Atomic Absorption Spectrometry... [Pg.5040]

If a sample solution is introduced into the center of the plasma, the constituent molecules are bombarded by the energetic atoms, ions, electrons, and even photons from the plasma itself. Under these vigorous conditions, sample molecules are both ionized and fragmented repeatedly until only their constituent elemental atoms or ions survive. The ions are drawn off into a mass analyzer for measurement of abundances and mJz values. Plasma torches provide a powerful method for introducing and ionizing a wide range of sample types into a mass spectrometer (inductively coupled plasma mass spectrometry, ICP/MS). [Pg.87]

To examine a sample by inductively coupled plasma mass spectrometry (ICP/MS) or inductively coupled plasma atomic-emission spectroscopy (ICP/AES) the sample must be transported into the flame of a plasma torch. Once in the flame, sample molecules are literally ripped apart to form ions of their constituent elements. These fragmentation and ionization processes are described in Chapters 6 and 14. To introduce samples into the center of the (plasma) flame, they must be transported there as gases, as finely dispersed droplets of a solution, or as fine particulate matter. The various methods of sample introduction are described here in three parts — A, B, and C Chapters 15, 16, and 17 — to cover gases, solutions (liquids), and solids. Some types of sample inlets are multipurpose and can be used with gases and liquids or with liquids and solids, but others have been designed specifically for only one kind of analysis. However, the principles governing the operation of inlet systems fall into a small number of categories. This chapter discusses specifically substances that are normally liquids at ambient temperatures. This sort of inlet is the commonest in analytical work. [Pg.103]

Samples to be examined by inductively coupled plasma and mass spectrometry (ICP/MS) are commonly in the form of a solution that is transported into the plasma flame. The thermal mass of the flame is small, and ingress of excessive quantities of extraneous matter, such as solvent, would cool the flame and might even extinguish it. Even cooling the flame reduces its ionization efficiency, with concomitant effects on the accuracy and detection limits of the ICP/MS method. Consequently, it is necessary to remove as much solvent as possible which can be done by evaporation off-line or done on-line by spraying the solution as an aerosol into the plasma flame. [Pg.137]

Gold is a useflil caUbration standard for this method (see Radioactive tracers). Whereas similar sensitivities can be achieved by inductively coupled plasma mass spectrometry (qv), the latter requires more extensive sample preparation to overcome interference by other metals such as copper (64). [Pg.381]

Inductively coupled plasma (icp) emission, direct current plasma (dcp), and inductively coupled plasma mass spectrometry (icp/ms) have taken over as the methods of choice for the simultaneous detection of metallic impurities in hafnium and hafnium compounds (29,30). [Pg.443]

Nickel also is deterrnined by a volumetric method employing ethylenediaminetetraacetic acid as a titrant. Inductively coupled plasma (ICP) is preferred to determine very low nickel values (see Trace AND RESIDUE ANALYSIS). The classical gravimetric method employing dimethylglyoxime to precipitate nickel as a red complex is used as a precise analytical technique (122). A colorimetric method employing dimethylglyoxime also is available. The classical method of electro deposition is a commonly employed technique to separate nickel in the presence of other metals, notably copper (qv). It is also used to estabhsh caUbration criteria for the spectrophotometric methods. X-ray diffraction often is used to identify nickel in crystalline form. [Pg.13]

Spectroscopic methods for the deterrnination of impurities in niobium include the older arc and spark emission procedures (53) along with newer inductively coupled plasma source optical emission methods (54). Some work has been done using inductively coupled mass spectroscopy to determine impurities in niobium (55,56). X-ray fluorescence analysis, a widely used method for niobium analysis, is used for routine work by niobium concentrates producers (57,58). Paying careful attention to matrix effects, precision and accuracy of x-ray fluorescence analyses are at least equal to those of the gravimetric and ion-exchange methods. [Pg.25]

Analytical and Test Methods. Ash in isophthahc acid refers to the residue left after combustion of the sample. Ash consists of oxides of trace metals that are deterrnined individually by atomic absorption or inductively coupled plasma. A Kad Fischer titration is specific for the water content. [Pg.494]

Potassium is analyzed in chemicals that are used in the fertilizer industry and in finished fertilizers by flame photometric methods (44) or volumetric sodium tertraphenylboron methods (45) as approved by the AO AC. Gravimetric deterrnination of potassium as K2PtClg, known as the Lindo-Gladding method (46), and the wet-digestion deterrnination of potassium (47) have been declared surplus methods by the AO AC. Other methods used for control purposes and special analyses include atomic absorption spectrophotometry, inductively coupled plasma (icp) emission spectrophotometry, and a radiometric method based on measuring the radioactivity of the minute amount of the isotope present in all potassium compounds (48). [Pg.536]

Numerous methods have been pubUshed for the determination of trace amounts of tellurium (33—42). Instmmental analytical methods (qv) used to determine trace amounts of tellurium include atomic absorption spectrometry, flame, graphite furnace, and hydride generation inductively coupled argon plasma optical emission spectrometry inductively coupled plasma mass spectrometry neutron activation analysis and spectrophotometry (see Mass spectrometry Spectroscopy, optical). Other instmmental methods include polarography, potentiometry, emission spectroscopy, x-ray diffraction, and x-ray fluorescence. [Pg.388]

Atomic Absorption/Emission Spectrometry. Atomic absorption or emission spectrometric methods are commonly used for inorganic elements in a variety of matrices. The general principles and appHcations have been reviewed (43). Flame-emission spectrometry allows detection at low levels (10 g). It has been claimed that flame methods give better reproducibiHty than electrical excitation methods, owing to better control of several variables involved in flame excitation. Detection limits for selected elements by flame-emission spectrometry given in Table 4. Inductively coupled plasma emission spectrometry may also be employed. [Pg.243]

The complex of the following destmctive and nondestmctive analytical methods was used for studying the composition of sponges inductively coupled plasma mass-spectrometry (ICP-MS), X-ray fluorescence (XRF), electron probe microanalysis (EPMA), and atomic absorption spectrometry (AAS). Techniques of sample preparation were developed for each method and their metrological characteristics were defined. Relative standard deviations for all the elements did not exceed 0.25 within detection limit. The accuracy of techniques elaborated was checked with the method of additions and control methods of analysis. [Pg.223]

Laser based mass spectrometric methods, such as laser ionization (LIMS) and laser ablation in combination with inductively coupled plasma mass spectrometry (LA-ICP-MS) are powerful analytical techniques for survey analysis of solid substances. To realize the analytical performances methods for the direct trace analysis of synthetic and natural crystals modification of a traditional analytical technique was necessary and suitable standard reference materials (SRM) were required. Recent developments allowed extending the range of analytical applications of LIMS and LA-ICP-MS will be presented and discussed. For example ... [Pg.425]

Inductively coupled plasma-mass spectrometry (ICP-MS) is a multielement analytical method with detection limits which are, for many trace elements, including the rare earth elements, better than those of most conventional techniques. With increasing availability of ICP-MS instalments in geological laboratories this method has been established as the most prominent technique for the determination of a large number of minor and trace elements in geological samples. [Pg.454]

Inductively Coupled Plasma-Optical (ICP-optical) methods and ICPMS are extremely sensitive elemental survey techniques that also are described in this volume. ICP methods, however, require a solution for analysis, so that the direct... [Pg.606]

Sulphate in Waters, Effluents and Solids (2nd Edition) [including Sulphate in Waters, Effluents and Some Solids by Barium Sulphate Gravimetry, Sulphate in waters and effluents by direct Barium Titrimetry, Sulphate in waters by Inductively Coupled Plasma Emission Spectrometry, Sulphate in waters and effluents by a Continuous Elow Indirect Spectrophotometric Method Using 2-Aminoperimidine, Sulphate in waters by Elow Injection Analysis Using a Turbidimetric Method, Sulphate in waters by Ion Chromatography, Sulphate in waters by Air-Segmented Continuous Elow Colorimetry using Methylthymol Blue], 1988... [Pg.315]

Samples Analyzed by Inductively Coupled Plasma (ICP) Metals — Where two or more of the following analytes are requested on the same filter, an ICP analysis may be conducted. However, the Industrial Hygienist should specify the metals of interest in the event samples cannot be analyzed by the ICP method. A computer print-out of the following 13 analytes may be typically reported Antimony, Beryllium, Cadmium, Chromium, Cobalt, Copper, Iron, Lead, Manganese, Molybdenum, Nickel, Vanadium, Zinc. Arsenic — Lead, cadmium, copper, and iron can be analyzed on the same filter with arsenic. [Pg.253]

The Production Department was not amused, because lower values had been expected. Quality Control was blamed for using an insensitive, unse-lective, and imprecise test, and thereby unnecessarily frightening top management. This outcome had been anticipated, and a better method, namely polarography, was already being set up. The same samples were run, this time in duplicate, with much the same results. A relative confidence interval of 25% was assumed. Because of increased specificity, there were now less doubts as to the amounts of this particular heavy metal that were actually present. To rule out artifacts, the four samples were sent to outside laboratories to do repeat tests with different methods X-ray fluorescence (XRFi °) and inductively coupled plasma spectrometry (ICP). The confidence limits were determined to be 10% resp. 3%. Figure 4.23 summarizes the results. Because each method has its own specificity pattern, and is subject to intrinsic artifacts, a direct statistical comparison cannot be performed without first correcting the apparent concentrations in order to obtain presumably true... [Pg.229]

Figure 4.23. Comparison of results on four batches using four different methods. The results are grouped according to batch, and within a group, the methods are sulfide precipitation, polarography. X-ray fluorescence, and inductively coupled plasma absorption (left to right). Figure 4.23. Comparison of results on four batches using four different methods. The results are grouped according to batch, and within a group, the methods are sulfide precipitation, polarography. X-ray fluorescence, and inductively coupled plasma absorption (left to right).

See other pages where Inductively coupled plasma method is mentioned: [Pg.230]    [Pg.5446]    [Pg.5445]    [Pg.277]    [Pg.35]    [Pg.197]    [Pg.425]    [Pg.435]    [Pg.172]    [Pg.275]    [Pg.287]    [Pg.547]    [Pg.230]    [Pg.5446]    [Pg.5445]    [Pg.277]    [Pg.35]    [Pg.197]    [Pg.425]    [Pg.435]    [Pg.172]    [Pg.275]    [Pg.287]    [Pg.547]    [Pg.4]    [Pg.97]    [Pg.449]    [Pg.524]    [Pg.177]    [Pg.335]    [Pg.317]    [Pg.134]    [Pg.332]    [Pg.247]    [Pg.622]    [Pg.625]    [Pg.356]   
See also in sourсe #XX -- [ Pg.176 ]




SEARCH



Analytical methods inductively coupled plasma-optical

Coupled Plasma

Coupled method coupling

Induction-coupled plasma

Inductive coupled plasma

Inductive coupling

Inductively couple plasma

Inductively couple plasma methods

Inductively couple plasma methods

Inductively coupled

Inductively coupled plasma optical emission sample preparation methods

Plasma method

© 2024 chempedia.info