A technique is any chemical or physical principle that can be used to study an analyte. Many techniques have been used to determine lead levels. For example, in graphite furnace atomic absorption spectroscopy lead is atomized, and the ability of the free atoms to absorb light is measured thus, both a chemical principle (atomization) and a physical principle (absorption of light) are used in this technique. Chapters 8-13 of this text cover techniques commonly used to analyze samples. [Pg.36]

Finally, analytical methods can be compared in terms of their need for equipment, the time required to complete an analysis, and the cost per sample. Methods relying on instrumentation are equipment-intensive and may require significant operator training. For example, the graphite furnace atomic absorption spectroscopic method for determining lead levels in water requires a significant capital investment in the instrument and an experienced operator to obtain reliable results. Other methods, such as titrimetry, require only simple equipment and reagents and can be learned quickly. [Pg.44]

Figure 15-12 is a schematic illustration of a technique known as acid volatile sulfides/ simultaneously extracted metals analysis (AVS/SEM). Briefly, a strong acid is added to a sediment sample to release the sediment-associated sulfides, acid volatile sulfides, which are analyzed by a cold-acid purge-and-trap technique (e.g., Allen et ai, 1993). The assumption shown in Fig. 15-12 is that the sulfides are present in the sediments in the form of either FeS or MeS (a metal sulfide). In a parallel analysis, metals simultaneously released with the sulfides (the simultaneously extracted metals) are also quantified, for example, by graphite furnace atomic absorption spectrometry. Metals released during the acid attack are considered to be associated with the phases operationally defined as "exchangeable," "carbonate," "Fe and Mn oxides," "FeS," and "MeS."... [Pg.400]

What advantage does ICP-MS usually have over graphite furnace atomic absorption, for example ... [Pg.296]

Other applications of supported liquid membranes have been related to metal speciation. For example, recently a system for chromium speciation has been developed based on the selective extraction and enrichment of anionic Cr(VI) and cationic Cr(III) species in two SLM units connected in series. Aliquat 336 and DEHPA were used respectively as carriers for the two species and graphite furnace atomic absorption spectrometry used for final metal determination. With this process, it was possible to determine chromium in its different oxidation states [103]. [Pg.582]

Inorganic extractables/leachables would include metals and other trace elements such as silica, sodium, potassium, aluminum, calcium, and zinc associated with glass packaging systems. Analytical techniques for the trace analysis of these elements are well established and include inductively coupled plasma—atomic emission spectroscopy (ICP-AES), ICP-MS, graphite furnace atomic absorption spectroscopy (GFAAS), electron microprobe, and X-ray fluorescence. Applications of these techniques have been reviewed by Jenke. " An example of an extractables study for certain glass containers is presented by Borchert et al. ". ... [Pg.1710]

The need for the determination of metallic constituents or impurities in pharmaceutical products has, historically, been addressed by ion chromatographic methods or various wet-bench methods (e.g. the USP heavy metals test). As the popularity of atomic spectroscopy has increased, and the equipment has become more affordable, spectroscopy-based techniques have been routinely employed to solve analytical problems in the pharmaceutical industry. Table 1 provides examples of metal determinations in pharmaceutical matrices, using spectroscopic techniques, and the reasons why these analyses are important. Flame atomic absorption spectrometry (FAAS), graphite furnace atomic absorption spectrometry... [Pg.629]

Trace and ultratrace determinations are now very important for chemicals. For solid chemicals, dissolution again may put limitations on the power of detection achievable due to contamination during the dissolution procedure. Graphite furnace atomic absorption together with plasma mass spectrometry are now of great importance in analyzing for the adds used, for example, in the treatment of surfaces in microelectronic components. [Pg.203]

The few articles currently available regarding trace analysis without preconcentration, use in general the graphite furnace technique [102,120, 138] with sample sizes of the order of microliters, and deal with the elements Sb [47, 83], Pb and Bi [48-50], As, Sb, Bi, Sn, Cd, Pb [10, 57, 116] as well as Al, Cr, Sn [6, 62], Co, and Mg [104]. Alkaline earths can be determined directly with the flame method [122, 147], Further techniques of atomic absorption by flame use concentration methods, for example for the determination of small concentrations of tin [17], Te [26], Co, Pb, and Bi [104], and W [106]. From the analytical viewpoint, it is only useful to remove the iron matrix. The extraction of the elements to be determined from the matrix always carries with it the danger of losses and therefore results showing concentrations that are too low. [Pg.219]

The first requirement can be easily fulfilled by the preconcentration of the analyte before the analysis. Preconcentration has been applied to sample preparation for flame atomic absorption (25) and, more recently, for ICP (79,80) spectroscopy. However, preconcentration is not completely satisfactory, because of the increased analysis time (which may be critical in clinical analysis) and the increased chance of contamination or sample loss. Most important, however, a larger initial sample size is necessary. The apparent solution is a more sensitive technique. Table 2 lists concentrations of various metals in whole blood or serum (81,82) in comparison to limits of detection for the various atomic spectroscopy techniques. In many cases, especially for the toxic heavy metals, only flameless atomic absorption using a graphite furnace can provide the necessary sensitivity and accommodate a sample of only a few microliters (Table 1). The determination of therapeutic gold in urine and serum (83,84), chromium in serum (85), skin (86) and liver (87), copper in semen (88), arsenic in urine (89), manganese in animal tissues (90), and lead in blood (91) are but a few examples in analyses which have utilized the flameless atomic absorption technique. [Pg.436]

The choice between flame atomic absorption spectrometry (FAAS) and graphite furnace AAS (GFAAS) will be determined by nature of the specimen. For example FAAS is ideal for serum copper determinations in which concentrations are normally between 12 and 26 //mol/L but GFAAS is needed to measure the concentrations of 0.1 to 0.8/rapid screening test for Wilson s Disease with which urine copper levels are usually greater than 3 tmol/L and can often exceed 10-20 fimo IL. [Pg.362]

The influence of other elements present in the flame or graphite furnace on the dissociation equilibria of the analyte can be a significant cause of chemical interference. As the absorption requires that the analyte prevails in the atomic state, dissociation of its compounds must occur, following for example the equations ... [Pg.463]


See other pages where Graphite furnace atomic absorption examples is mentioned: [Pg.48]    [Pg.714]    [Pg.218]    [Pg.140]    [Pg.10]    [Pg.658]    [Pg.68]    [Pg.157]    [Pg.107]    [Pg.41]    [Pg.22]    [Pg.241]    [Pg.620]    [Pg.1408]    [Pg.224]    [Pg.112]    [Pg.215]    [Pg.528]    [Pg.448]    [Pg.41]    [Pg.240]    [Pg.1544]    [Pg.605]    [Pg.83]    [Pg.241]    [Pg.182]    [Pg.325]    [Pg.14]    [Pg.3369]    [Pg.134]    [Pg.296]    [Pg.600]    [Pg.1]    [Pg.473]    [Pg.101]    [Pg.9]    [Pg.444]    [Pg.299]   