Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Samplings, initial

Here, we give here a brief outline of the methods as introduced in Refs. 43, 44, and 47. Suppose that the initial state of the system is tpoili, ,<]n) From ipo, the Wigner phase-space distribution D(qi,..., qn pi,. ..,Pn] is computed. This distribution is used to sample initial positions and momenta, . .., for a classical trajectory simulation of the process of... [Pg.368]

Progress of a liquid-liquid extraction using two identical extractions of a sample (initial phase) with fresh portions of the extracting phase. All numbers are fractions of solute in the phases A = analyte, I = interferent. [Pg.545]

It follows that the elution curve for a sample, initially dispersed over (r) plates, will be... [Pg.192]

The advantage of the stoichiometric technique is that it is extremely simple. Care has to be taken to remove all gases dissolved in the IL sample initially, but this is easily accomplished because one does not have to worry about volatilization of the IL sample when the sample chamber is evacuated. The disadvantage of this technique is that it requires relatively large amounts of ILs to obtain accurate measurements for gases that are only sparingly soluble. At ambient temperature and pressure, for instance, 10 cm of l-n-butyl-3-methylimida2olium hexafluorophosphate ([BMIM][PFg]) would take up only 0.2 cm of a gas with a Henry s law constant of... [Pg.84]

Fig. 66a. GPC traces of a PS sample (initial M = 4.34 xlO6, Mw/M = 1.06), initial concentration = 200 ppm before and after 50 cycles of freeze-and-thaw degradation (the curves are normalized to the same height), b Molecular weight distribution of the virgin... Fig. 66a. GPC traces of a PS sample (initial M = 4.34 xlO6, Mw/M = 1.06), initial concentration = 200 ppm before and after 50 cycles of freeze-and-thaw degradation (the curves are normalized to the same height), b Molecular weight distribution of the virgin...
Figure 10. Calculated changes in the mouse bioassay toxicity of a sample initially containing 1 xmol of toxin C2. The horizontal axis represents the percentage of 11- -hydroxysulfate. The lower line indicates the toxicity of the sample with the 21-sulfo group intact, but with varying degrees of epimerization. The upper line indicates the toxicity of the corresponding carbamates, formed by hydrolysis of the 21-sulfo group. Figure 10. Calculated changes in the mouse bioassay toxicity of a sample initially containing 1 xmol of toxin C2. The horizontal axis represents the percentage of 11- -hydroxysulfate. The lower line indicates the toxicity of the sample with the 21-sulfo group intact, but with varying degrees of epimerization. The upper line indicates the toxicity of the corresponding carbamates, formed by hydrolysis of the 21-sulfo group.
Fig. 4 Fast time-resolved spectra of ethylene polymerization reaction on CO-reduced Cr/Si02 sample. Initial ethylene pressure was 10 Torr. Last spectrum after 15 s. Reprinted from [77]. Copyright (1994) by Elsevier... Fig. 4 Fast time-resolved spectra of ethylene polymerization reaction on CO-reduced Cr/Si02 sample. Initial ethylene pressure was 10 Torr. Last spectrum after 15 s. Reprinted from [77]. Copyright (1994) by Elsevier...
Admission urine PCP assays were done on 155 consecutive males admitted over a g-month period (December 1982 to August 1983) to a mixed abuse ward (20 beds). Forty-two patients (27 percent) had PCP detected in their urine another 14 (9 percent) gave a history of PCP use. Of these, 14 (9 percent of the total sample) initially denied any PCP use, and 9 continued to deny use after they were confronted with the laboratory results. [Pg.234]

Obtain either a quantitative or semiquantitative culture of a lower respiratory sample. Initiate empirical broad-spectrum antibiotic therapy. [Pg.1053]

Sample Initial Decomposition Temperature (°c) Temperature of 5% Weight Loss (°c)... [Pg.234]

A typical sorption experiment involves exposing a polymer sample, initially at an equilibrium penetrant concentration of c to a bathing penetrant concentration of Ci. The weight gain or loss is then measured as a function of time. The term sorption used in this context includes both absorption and desorption. The sorption is of the integral type if c° = 0 in the case of absorption or if cf = 0 in the case of desorption. Details of the experimental setup for the sorption measurement are discussed elsewhere [4],... [Pg.461]

The objective of the present work was to determine the influence of the light intensity on the polymerization kinetics and on the temperature profile of acrylate and vinyl ether monomers exposed to UV radiation as thin films, as well as the effect of the sample initial temperature on the polymerization rate and final degree of cure. For this purpose, a new method has been developed, based on real-time infrared (RTIR) spectroscopy 14, which permits to monitor in-situ the temperature of thin films undergoing high-speed photopolymerization, without introducing any additive in the UV-curable formulation 15. This technique proved particularly well suited to addressing the issue of thermal runaway which was recently considered to occur in laser-induced polymerization of divinyl ethers 13>16. [Pg.64]

Sample, Initial Concentration, and Other Variables Persistence Reference8... [Pg.991]

Determine the final temperature of a sample of hydrogen gas. The sample initially occupied a volume of 6.00 L at 127°C and 875 mm Hg. The sample was heated, at constant pressure, until it occupied a volume of 15 00 L. [Pg.308]

It is notable that the GC samples in Table 4.1 are much too short for the Intermediate Zone formula to apply out to 120 ns. The formulas for subsequent zones of C (t) (Eqs. 4.38—4.41) are employed as needed and yield the same value of a for both 230- and 590-bp samples.(146) The 590-bp sample initially exhibited a threefold higher value, which relaxed over several months, during which time many very small fragments dissociated from, or annealed out of, the predominant 590-bp species. This was tentatively attributed to the presence of branched structures, which exhibit high affinity sites for ethidiuny in the original material. Both gel electrophoretic and electron microscopic 147 1 evidence for branched structures in poly(dG-dC) were noted.(146) The 500-bp length from gel electrophoresis was confirmed by sedimentation.(146)... [Pg.190]

To initiate an H/D exchange reaction, a protein sample, initially in non-deuterated buffer, is incubated in a buffer with 50-90% mole fraction deuterated water. There are almost no restrictions on reaction conditions which allow exchange behavior to be studied as a function of protein and buffer composition, solution pH, and in the presence and absence of ligands. To follow the deuterium buildup of individual amide hydrogen or sets of hydrogens, several on exchange time points are sampled for each condition. [Pg.380]

Element Form Sample Initial Concentration, % Removal ppm... [Pg.133]

Experimental results obtained in Ref. [4] illustrate clearly that devices based on thin wires provide a more uniform charge distribution and thus may be recommended for XTOF spectroscopy. In order to control the sample initial voltage, a biased grid is inserted between the corona emitter and the floating surface of the sample. [Pg.84]


See other pages where Samplings, initial is mentioned: [Pg.327]    [Pg.231]    [Pg.125]    [Pg.153]    [Pg.263]    [Pg.134]    [Pg.101]    [Pg.106]    [Pg.460]    [Pg.302]    [Pg.86]    [Pg.98]    [Pg.384]    [Pg.51]    [Pg.990]    [Pg.231]    [Pg.128]    [Pg.123]    [Pg.388]    [Pg.431]    [Pg.110]    [Pg.52]    [Pg.650]    [Pg.225]    [Pg.270]    [Pg.178]    [Pg.192]    [Pg.990]    [Pg.17]    [Pg.220]   
See also in sourсe #XX -- [ Pg.124 ]




SEARCH



Good laboratory practice in initial sample preparation

Initial sample preparation

New Platform for Sampling and Sensor Initiative (NeSSI)

New Sampling Sensor Initiative

New Sampling and Sensor Initiative

New platform for sampling and sensor initiative

Sample applying initial load

Samples, explosive other than initiating explosives

Sampling of initial conditions

Selection of Optimal Sampling Interval and Initial State for Precise Parameter Estimation

© 2024 chempedia.info