Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

From other methods

An example of the neural network prediction of NMR chemical shifts for a natural product is illustrated in Figure 10.2-7 together with the calculations from other methods. This molecule was chosen as it had been discovered [47]... [Pg.527]

A more complex set of functionals utilizes the electron density and its gradient. These are called gradient-corrected methods. There are also hybrid methods that combine functionals from other methods with pieces of a Hartree-Fock calculation, usually the exchange integrals. [Pg.43]

Post-exposure techniques are well documented for a variety of metals (ASTM and NACE). A disadvantage of coupon techniques is that the response to severe corrosion that may occur for short periods of time is not detected because the response measured is only an average for the period of exposure, although coupons can be withdrawn at intervals of time provided a sufficient number are placed at the start of exposure. The important aspect of coupons is that data obtained from their use can be used as base-line and therefore can be used to correlate corrosion data from other methods. [Pg.1135]

Yet we must agree, there are advantages to the direct vision type of experiment. Often more detailed information can be obtained this way. Is the garbage collector tall Does he have a mustache Could the garbage collector be a woman This type of information is less easily obtained from other methods of observation. It is worthwhile setting the alarm clock, even after we have become convinced there is a garbage collector. [Pg.234]

Various techniques and equipment are available for the measurement of particle size, shape, and volume. These include for microscopy, sieve analysis, sedimentation methods, photon correlation spectroscopy, and the Coulter counter or other electrical sensing devices. The specific surface area of original drug powders can also be assessed using gas adsorption or gas permeability techniques. It should be noted that most particle size measurements are not truly direct. Because the type of equipment used yields different equivalent spherical diameter, which are based on totally different principles, the particle size obtained from one method may or may not be compared with those obtained from other methods. [Pg.278]

Recommendations Recommended for internal inspection of pressure vessels to use in addition to UT techniques, recognizing its limitation for advanced stages of HTHA and not finding microscopic stages of HTHA. Can be used to follow-up indications from other methods or at suspected hot spots where damage is suspected. Not recommended for general HTHA detection. May be useful for verification of shear wave UT indications. Recommended for internal inspection of pressure vessels to use in addition to UT MT techniques. Additional development work and field trials recommended. Not currendy recommended as a primary method for HTHA detection. [Pg.55]

Geometric Optimization. The structure of the molecule as built by CHEMLAB (or a input from other methods) can be optimized through either a full force field molecular mechanics calculation (MMII) or with the semi-empirical molecular orbital methods MINDO-3 and MNDO. [Pg.32]

Table 13.1 summarizes the common chromatographic methods and the characteristics that differentiate them from other methods. In this list, HPLC... [Pg.272]

The advantage of this approach is that it can be used when the response of the electrode is not Nernstian or even linear. However, the drawback is that the selectivity coefficient may change under different experimental conditions, particularly the concentrations at which the measurements were made. In most situations, the selectivity obtained from matched potential method cannot be directly compared to the values obtained from other methods. [Pg.654]

Wayner and colleagues stated in their publication that the voltammograms obtained for the species investigated are not reversible. However, the redox potentials derived from the half-wave potentials are generally in good agreement (within 100 mV) with the data determined from other methods [351]. The application of R+/R) and (R/R-) values in thermochemical cycles that... [Pg.246]

What truly distinguishes the asymmetric Birch reduction-alkylation protocol from other methods for preparation of non-... [Pg.5]

A traditional object for testing new methods is germanium. The ehemieal bonding in Ge was studied by X-ray diffraction, Hartree-Fock methods and density functional theory for which good agreement of electron densities was reached. Hence the ESP calculated from eleetron diffraction were also compared with the above results obtained from other methods. [Pg.117]

Calculated sulfate-sulfide temperatures, for conditions of complete isotope equilibrium, are typically between 450 and 600°C and agree well with temperatures estimated from other methods. Thus, the sulfur isotope data and temperatures support the magmatic origin of the snlfnr in porphyry deposits. [Pg.133]

A usual practice for laboratories is to include in the scope of their accreditation a selection of methods they use. The standard provides for certain rules to be followed in reports including results from other methods as well in any relevant declarations. However, the management issues addressed in the quality management system, following ISO/IEC 17025, cover the overall operation of the laboratory. [Pg.89]

In the present paper we tried to demonstrate that the problems faced by most empirical and by (actual and so called) ab initio techniques when applied to modelling TMCs have deep roots in the specific features of the electronic structure of the latter and in approximations which tacitly drop the necessary elements of the theory required to reproduce these features. Of course, the EHCF approach whose success story is described here in details is not completely isolated from other methods. In general picture, the various CAS techniques must be mentioned in relation to it. The char-... [Pg.495]

In CBED, zone-axis patterns (ZAP) can be recorded near the relevant zone axis and the pattern may also include a higher-order Laue zone (referred to as a HOLZ). The radius of the first HOLZ ring G is related to the periodicity along the zone axis [c] and the electron wavelength, by = 2/kc. CBED can thus provide reciprocal space data in all three (x,y,z) dimensions, typically with a lateral resolution of a few nanometres. As in any application, corroborative evidence from other methods such as HRTEM and single-crystal x-ray diffraction, where possible, can be productive in an unambiguous structural determination of complex and defective materials such as catalysts. We illustrate some examples in later sections. [Pg.61]

One of the present authors has extensively used the dipole-moment method to calculate conformational equilibria of saturated heterocycles. In hindsight this has been a frustrating experience not so much because of the assumptions and approximations that must be made, but because the results in some cases are in good agreement with those derived from other methods, whereas for other groups of compounds the dipole-moment conclusions are clearly incorrect. In this discussion we first discuss the method, using piperidines as an example, and then attempt to assess its areas of applicability and causes of failure. [Pg.39]

The values given in Table XI (Section III,A,1) for the A-methylpiperidine equilibria show that dipole-moment measurements with the associated assumptions consistently give rise to lower estimates of — AG° than those from other methods. [Pg.41]

However, in many other series results have been obtained that are compatible with those from other methods and that gave the dipole-moment method an appearance of general reliability now known to be unjustified. Such compatible results include spiropiperidines (Section III,A,4), tropanes (Section III,B,4), 2-alkyltetrahydro-l,2-oxazines (Section III,C,2), perhydro-pyrido[l,2-c][l,3]oxazines (Section III,D,IX perhydropyrido[l,2-c][l,3]thi-azines (Section III,D,2), dialkylhexahydropyrimidines and perhydropyrido-[l,2-c]pyrimidines (Section III,D,3), 5-alkyldihydro-l,3,5-dithiazines (Section III,G,3), 3,5-dialkyltetrahydro-l,3,5-thiadiazines (Section III,G,4) and, in part, l,2,4,5-tetraalkylhexahydro-l,2,4,5-tetrazines (Section III,H,4) as well as piperidines, tetrahydro-l,3-oxazines, and tetrahydro-l,3-thiazines containing an N-H group. [Pg.41]

For the 1,2,4,6-tetramethylpiperidine equilibrium 123 124, AH° = 1.0 kcal mol-1, and for the N-methylpiperidine equilibrium, AH° = 0.88 kcal mol 1 and refer to measurements made on pure liquids. These values are much lower than those obtained by most other techniques (Table XI) and it is agreed2 that values of AH0 obtained by spectroscopic methods are more reliable than those from ultrasonic techniques. AH (axial -> transition state) values, however, are in agreement with those from other methods, and for Af-methylpiperidine a value of 5.02 kcal mol-1 has been obtained from Eyring plots and a value of 5.76kcal mol l, using the foregoing equation.171... [Pg.58]

Because the handling of the samples in the electron microscope introduces some uncertainties, supplementary evidence from other methods of investigation is urgently needed. In the case of optically clear polymers... [Pg.5]

This paper describes an ebulliometric system for routine and special determinations of molecular weights. The system uses a simple ebulliometer, an immersion heater, and a Cottrell-type pump. Temperature sensing is by differential thermopile. Precision varies from about 1 to 6%, and values compare well with those from other laboratories and those from other methods. Values as high as 170,000 have been successfully measured. Some problems encountered in using the ebulliometric method are selection and effect of reference temperature, limitations of the vapor lift pump and a possible substitute for it, measurement of equilibrium concentrations within the operating ebulliometer, and the experimentally determined ebulliometric constant and some factors which influence its value. [Pg.7]


See other pages where From other methods is mentioned: [Pg.62]    [Pg.2]    [Pg.271]    [Pg.184]    [Pg.173]    [Pg.71]    [Pg.30]    [Pg.32]    [Pg.353]    [Pg.123]    [Pg.76]    [Pg.77]    [Pg.49]    [Pg.91]    [Pg.353]    [Pg.314]    [Pg.227]    [Pg.332]    [Pg.237]    [Pg.43]    [Pg.271]    [Pg.62]    [Pg.184]    [Pg.72]    [Pg.398]    [Pg.75]    [Pg.42]    [Pg.693]    [Pg.30]   
See also in sourсe #XX -- [ Pg.376 ]




SEARCH



From others

Others methods

© 2024 chempedia.info