Flame absorption spectroscopy

Biological fluids such as serum or plasma, red blood cells, and urine are particularly diflBcult to analyze. The low molybdenum concentrations found in normal human samples are below the detection limit of the thiocyanate colorimetric method (100 ng) and much below conventional flame absorption spectroscopy (1 /xg). Normal blood levels of molybdenum are about 10 /xg/L and sample volume is usually < 1 mL. The low concentration and limited sample size preclude direct analysis or sample preconcentration for analysis by the conventional analytical methods. [Pg.34]

The elements Na, K, Li, Mg, Ca, Al, and Zn are among the most common elements subjected to pharmaceutical analysis and coincidentally are also among the elements most readily determinable by flame emission. Although it is not as versatile as other methods, flame emission spectroscopy exhibits sensitivity greater than or approximately equal to that of flame absorption spectroscopy for the above elements (Table 2). Where precision of the analysis is critical, however, the analyst should consider the alternative of atomic absorption spectroscopy. [Pg.434]

Final determination flame-absorption spectroscopy Equipment parameters as described for direct determination... [Pg.303]

The recommended method of determination is direct analysis by means of flame absorption spectroscopy (3.. 20.1). Alternatively initial concentration is required (3.4.20.2) or the flameless AAS technique should be... [Pg.409]

The section on Spectroscopy has been expanded to include ultraviolet-visible spectroscopy, fluorescence, Raman spectroscopy, and mass spectroscopy. Retained sections have been thoroughly revised in particular, the tables on electronic emission and atomic absorption spectroscopy, nuclear magnetic resonance, and infrared spectroscopy. Detection limits are listed for the elements when using flame emission, flame atomic absorption, electrothermal atomic absorption, argon ICP, and flame atomic fluorescence. Nuclear magnetic resonance embraces tables for the nuclear properties of the elements, proton chemical shifts and coupling constants, and similar material for carbon-13, boron-11, nitrogen-15, fluorine-19, silicon-29, and phosphorus-31. [Pg.1287]

Absorbance profile for Ag and Cr in flame atomic absorption spectroscopy. [Pg.414]

M HNO3. The concentration of Cu and Zn in the diluted supernatant is determined by atomic absorption spectroscopy using an air-acetylene flame and external standards. Copper is analyzed at a wavelength of 324.8 nm with a slit width of 0.5 nm, and zinc is analyzed at 213.9 nm with a slit width of 1.0 nm. Background correction is used for zinc. Results are reported as micrograms of Cu or Zn per gram of FFDT. [Pg.421]

Scale of Operation Atomic absorption spectroscopy is ideally suited for the analysis of trace and ultratrace analytes, particularly when using electrothermal atomization. By diluting samples, atomic absorption also can be applied to minor and major analytes. Most analyses use macro or meso samples. The small volume requirement for electrothermal atomization or flame microsampling, however, allows the use of micro, or even ultramicro samples. [Pg.422]

Use of glow-discharge and the related, but geometrically distinct, hoUow-cathode sources involves plasma-induced sputtering and excitation (93). Such sources are commonly employed as sources of resonance-line emission in atomic absorption spectroscopy. The analyte is vaporized in a flame at 2000—3400 K. Absorption of the plasma source light in the flame indicates the presence and amount of specific elements (86). [Pg.114]

Two colorimetric methods are recommended for boron analysis. One is the curcumin method, where the sample is acidified and evaporated after addition of curcumin reagent. A red product called rosocyanine remains it is dissolved in 95 wt % ethanol and measured photometrically. Nitrate concentrations >20 mg/L interfere with this method. Another colorimetric method is based upon the reaction between boron and carminic acid in concentrated sulfuric acid to form a bluish-red or blue product. Boron concentrations can also be deterrnined by atomic absorption spectroscopy with a nitrous oxide—acetjiene flame or graphite furnace. Atomic emission with an argon plasma source can also be used for boron measurement. [Pg.231]

Atomic absorption spectroscopy is more suited to samples where the number of metals is small, because it is essentially a single-element technique. The conventional air—acetylene flame is used for most metals however, elements that form refractory compounds, eg, Al, Si, V, etc, require the hotter nitrous oxide—acetylene flame. The use of a graphite furnace provides detection limits much lower than either of the flames. A cold-vapor-generation technique combined with atomic absorption is considered the most suitable method for mercury analysis (34). [Pg.232]

Atomic absorption spectroscopy is an alternative to the colorimetric method. Arsine is stiU generated but is purged into a heated open-end tube furnace or an argon—hydrogen flame for atomi2ation of the arsenic and measurement. Arsenic can also be measured by direct sample injection into the graphite furnace. The detection limit with the air—acetylene flame is too high to be useful for most water analysis. [Pg.232]

Barium can also be deterruined by x-ray fluorescence (XRF) spectroscopy, atomic absorption spectroscopy, and flame emission spectroscopy. Prior separation is not necessary. XRF can be appHed directly to samples of ore or products to yield analysis for barium and contaminants. AH crystalline barium compounds can be analy2ed by x-ray diffraction. [Pg.484]

Instrumental Quantitative Analysis. Methods such as x-ray spectroscopy, oaes, and naa do not necessarily require pretreatment of samples to soluble forms. Only reUable and verified standards are needed. Other instmmental methods that can be used to determine a wide range of chromium concentrations are atomic absorption spectroscopy (aas), flame photometry, icap-aes, and direct current plasma—atomic emission spectroscopy (dcp-aes). These methods caimot distinguish the oxidation states of chromium, and speciation at trace levels usually requires a previous wet-chemical separation. However, the instmmental methods are preferred over (3)-diphenylcarbazide for trace chromium concentrations, because of the difficulty of oxidizing very small quantities of Cr(III). [Pg.141]

The capacity factors of SN-SiO, for metal ions were determined under a range of different conditions of pH, metal ions concentrations and time of interaction. Preconcentration of Cd ", Pb ", Zn " and CvS were used for their preliminary determination by flame atomic absorption spectroscopy. The optimum pH values for quantitative soi ption ai e 5.8, 6.2, 6.5, 7.0 for Pb, Cu, Cd and Zn, respectively. The sorption ability of SN-SiO, to metal ions decrease in line Pb>Cu> >Zn>Cd. The soi ption capacity of the sorbent is 2.7,7.19,11.12,28.49 mg-g Hor Cd, Zn, Pb, andCu, respectively. The sorbent distribution coefficient calculated from soi ption isotherms was 10 ml-g for studied cations. All these metal ions can be desorbed with 5 ml of O.lmole-k HCl (sorbent recovery average out 96-100%). [Pg.274]

The possibility of preconcentration of selenium (IV) by coprecipitation with iron (III) hydroxide and lanthanum (III) hydroxide with subsequent determination by flame atomic absorption spectroscopy has been investigated also. The effect of nature and concentration of collector and interfering ions on precision accuracy and reproducibility of analytical signal A has been studied. Application of FefOH) as copreconcentrant leads to small relative error (less than 5%). S, is 0.1-0.2 for 5-100 p.g Se in the sample. Concentration factor is 6. The effect of concentration of hydrochloric acid on precision and accuracy of AAS determination of Se has been studied. The best results were obtained with HCl (1 1). [Pg.293]

All the alkali metals have characteristic flame colorations due to the ready excitation of the outermost electron, and this is the basis of their analytical determination by flame photometry or atomic absorption spectroscopy. The colours and principal emission (or absorption) wavelengths, X, are given below but it should be noted that these lines do not all refer to the same transition for example, the Na D-line doublet at 589.0, 589.6 nm arises from the 3s — 3p transition in Na atoms formed by reduction of Na+ in the flame, whereas the red line for lithium is associated with the short-lived species LiOH. [Pg.75]

Atomic absorption spectroscopy involves atomising the specimen, often by spraying a solution of the sample into a flame, and then studying the absorption of radiation from an electric lamp producing the spectrum of the element to be determined. [Pg.7]

Although APDC complexes are soluble in many organic solvents, it is found that 4-methylpent-2-one (isobutyl methyl ketone) and heptan-2-one (n-pentyl methyl ketone) are, in general, the most satisfactory for direct nebulisation into the air/acetylene flame used in atomic absorption spectroscopy. [Pg.171]

Magnesium may conveniently be determined by atomic absorption spectroscopy (Section 21.21) if a smaller amount (ca 4 mg) is used for the separation. Collect the magnesium effluent in a 1 L graduated flask, dilute to the mark with de-ionised water and aspirate the solution into the flame of an atomic absorption spectrometer. Calibrate the instrument using standard magnesium solutions covering the range 2 to 8 ppm. [Pg.209]

A schematic diagram showing the disposition of these essential components for the different techniques is given in Fig. 21.3. The components included within the frame drawn in broken lines represent the apparatus required for flame emission spectroscopy. For atomic absorption spectroscopy and for atomic fluorescence spectroscopy there is the additional requirement of a resonance line source, In atomic absorption spectroscopy this source is placed in line with the detector, but in atomic fluorescence spectroscopy it is placed in a position at right angles to the detector as shown in the diagram. The essential components of the apparatus required for flame spectrophotometric techniques will be considered in detail in the following sections. [Pg.783]

Instead of employing the high temperature of a flame to bring about the production of atoms from the sample, it is possible in some cases to make use of either (a) non-flame methods involving the use of electrically heated graphite tubes or rods, or (b) vapour techniques. Procedures (a) and (b) both find applications in atomic absorption spectroscopy and in atomic fluorescence spectroscopy. [Pg.787]

As indicated in Fig. 21.3, for both atomic absorption spectroscopy and atomic fluorescence spectroscopy a resonance line source is required, and the most important of these is the hollow cathode lamp which is shown diagrammatically in Fig. 21.8. For any given determination the hollow cathode lamp used has an emitting cathode of the same element as that being studied in the flame. The cathode is in the form of a cylinder, and the electrodes are enclosed in a borosilicate or quartz envelope which contains an inert gas (neon or argon) at a pressure of approximately 5 torr. The application of a high potential across the electrodes causes a discharge which creates ions of the noble gas. These ions are accelerated to the cathode and, on collision, excite the cathode element to emission. Multi-element lamps are available in which the cathodes are made from alloys, but in these lamps the resonance line intensities of individual elements are somewhat reduced. [Pg.790]

With flame emission spectroscopy, there is greater likelihood of spectral interferences when the line emission of the element to be determined and those due to interfering substances are of similar wavelength, than with atomic absorption spectroscopy. Obviously some of such interferences may be eliminated by improved resolution of the instrument, e.g. by use of a prism rather than a filter, but in certain cases it may be necessary to select other, non-interfering, lines for the determination. In some cases it may even be necessary to separate the element to be determined from interfering elements by a separation process such as ion exchange or solvent extraction (see Chapters 6, 7). [Pg.792]


See other pages where Flame absorption spectroscopy is mentioned: [Pg.180]    [Pg.64]    [Pg.1412]    [Pg.1381]    [Pg.1409]    [Pg.28]    [Pg.180]    [Pg.64]    [Pg.1412]    [Pg.1381]    [Pg.1409]    [Pg.28]    [Pg.1282]    [Pg.459]    [Pg.65]    [Pg.17]    [Pg.524]    [Pg.177]    [Pg.317]    [Pg.317]    [Pg.393]    [Pg.205]    [Pg.779]    [Pg.779]    [Pg.780]    [Pg.781]    [Pg.782]    [Pg.783]    [Pg.784]    [Pg.785]    [Pg.786]    [Pg.788]   
See also in sourсe #XX -- [ Pg.34 ]

See also in sourсe #XX -- [ Pg.13 , Pg.397 ]




SEARCH



Atomic absorption and flame emission spectroscopy

Flame-atomic absorption spectroscopy

Flames in atomic absorption spectroscopy

Hydride generation-flame atomic absorption spectroscopy

Interferences flame atomic absorption spectroscopy

Metals flame atomic absorption spectroscopy

Nebulizers flame atomic absorption spectroscopy

Temperatures flame atomic absorption spectroscopy