The comparison of detection limits Is a fundamental part of many decision-making processes for the analytical chemist. Despite numerous efforts to standardize methodology for the calculation and reporting of detection limits, there is still a wide divergence In the way they appear in the literature. This paper discusses valid and invalid methods to calculate, report, and compare detection limits using atomic spectroscopic techniques. Noises which limit detection are discussed for analytical methods such as plasma emission spectroscopy, atomic absorption spectroscopy and laser excited atomic fluorescence spectroscopy. [Pg.109]

The focus of this section is the emission of ultraviolet and visible radiation following thermal or electrical excitation of atoms. Atomic emission spectroscopy has a long history. Qualitative applications based on the color of flames were used in the smelting of ores as early as 1550 and were more fully developed around 1830 with the observation of atomic spectra generated by flame emission and spark emission.Quantitative applications based on the atomic emission from electrical sparks were developed by Norman Lockyer (1836-1920) in the early 1870s, and quantitative applications based on flame emission were pioneered by IT. G. Lunde-gardh in 1930. Atomic emission based on emission from a plasma was introduced in 1964. [Pg.434]

In Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES), a gaseous, solid (as fine particles), or liquid (as an aerosol) sample is directed into the center of a gaseous plasma. The sample is vaporized, atomized, and partially ionized in the plasma. Atoms and ions are excited and emit light at characteristic wavelengths in the ultraviolet or visible region of the spectrum. The emission line intensities are proportional to the concentration of each element in the sample. A grating spectrometer is used for either simultaneous or sequential multielement analysis. The concentration of each element is determined from measured intensities via calibration with standards. [Pg.48]

Knowledge on the plasma species can be obtained by the use of plasma diagnostics techniques, such as optical emission spectroscopy (OES) and mass spectroscopy (MS). Both techniques are able to probe atomic and molecular, neutral or ionized species present in plasmas. OES is based on measuring the light emission spectrum that arises from the relaxation of plasma species in excited energy states. MS, on the other hand, is generally based on the measurement of mass spectra of ground state species. [Pg.236]

Wrembel and Pajak [486] evaporated mercury from natural water samples with argon and amalgamated the mercury with a gold foil. The mercury was excited in a ring-discharge plasma and determined by atomic emission spectroscopy. The method was applied to the determination of mercury in seawater in the range 0.01-1.0 xg/l. [Pg.201]

In reference 190, the authors describe the spectroscopic and X-ray crystallographic techniques they used to determine the pMMO structure. First, EPR and EX AFS experiments indicated a mononuclear, type 2 Cu(II) center hgated by histidine residues and a copper-containing cluster characterized by a 2.57 A Cu-Cu interaction. A functional iron center was also indicated by Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES). ICP-AES uses inductively coupled plasma to produce excited atoms that emit electromagnetic radiation at a wavelength characteristic of a particular element. The intensity of this emission is indicative of the concentration of the element (iron in this case) within the sample. [Pg.464]

Emission spectroscopy utilizes the characteristic line emission from atoms as their electrons drop from the excited to the ground state. The earliest version of emission spectroscopy as applied to chemistry was the flame test, where samples of elements placed in a Bunsen burner will change the flame to different colors (sodium turns the flame yellow calcium turns it red, copper turns it green). The modem version of emission spectroscopy for the chemistry laboratory is ICP-AES. In this technique rocks are dissolved in acid or vaporized with a laser, and the sample liquid or gas is mixed with argon gas and turned into a plasma (ionized gas) by a radio frequency generator. The excited atoms in the plasma emit characteristic energies that are measured either sequentially with a monochromator and photomultiplier tube, or simultaneously with a polychrometer. The technique can analyze 60 elements in minutes. [Pg.525]

The ionization energy of Ar is 15.8 electron volts (eV), which is higher than those of all elements except He, Ne, and F. In an Ar plasma, analyte elements can be ionized by collisions with Ar+, excited Ar atoms, or energetic electrons. In atomic emission spectroscopy, we usually observe the more abundant neutral atoms, M. However, the plasma can be directed into a mass spectrometer (Chapter 22), which separates and measures ions according to their mass-to-charge ratio.17 For the most accurate measurements of isotope ratios, the mass spectrometer has one detector for each desired isotope.18... [Pg.468]

Atomic emission spectroscopy can be employed, generally with an inductively coupled plasma for thermal excitation. The sample is introduced into the plasma as a mist of ultrafine droplets, and the monochromator and detector are set to measure the intensity of an atomic emission line characteristic of the element. This technique is powerful, general, sensitive, linear, and able to measure over 70 elements, and, as a result, is widely used. Response is typically linear over four orders of magnitude in concentration with relative standard deviations of 1 to 3%. In low-salt aqueous solutions, detection limits range from 10 to 1000 nanomolar without preconcentration. Significant problems with saline samples remain, but use of Babington nebulizers alleviates these problems somewhat. [Pg.60]

Emission spectroscopy is the most popular since it is easy to implement. It is frequently used in industrial equipment for real-time control of a process. Very fine qualitative information of the plasma composition can be obtained. The drawback of this technique is that it provides information from excited species. These are only a small fraction of the total number of species, and they may be produced by more than one excitation pathway. Indeed the measured intensity /a emitted by electron-excited species A from the ground state A can be expressed as ... [Pg.451]

This system forms highly ionized so-called Penning mixtures [12,13]. The higher excited states of Hj are partly stable and partly unstable, depending on the quantum numbers of the electron present. The stable excited states have, however, only very shallow minima of the potential curves [14]. That is the reason why no spectrum of Hj is observed for the helium plasma jet. The argon excited neutrals, on the other hand, cannot ionize hydrogen atoms or molecules, but could produce excited H2 molecules, which can be detected by optical emission spectroscopy. [Pg.349]

In 1960, emission spectroscopy was displaced by the arrival of atomic absorption spectroscopy but experienced a revival in 1970 with the appearance of modem excitation sources, such as Inductively Coupled Plasma (ICP), the development of electronic detection methods and microprocessor technology. [Pg.55]

Graphite furnace AAS Atomic fluorescence spectroscopy Inductively-coupled-plasma optical-emission spectroscopy Glow-discharge optical-emission spectroscopy Laser-excited resonance ionization spectroscopy Laser-excited atomic-fluorescence spectroscopy Laser-induced-breakdown spectroscopy Laser-induced photocoustic spectroscopy Resonance-ionization spectroscopy... [Pg.208]

For ICP-OES-MS (inductively coupled plasma-optical emission spectroscopy-mass spectroscopy) work, the desolvator will remove oxide and hydride polyatomic ion interferences, i.e. ArO+ is reduced 100 fold, which allows for improved detection of Fe. The solvent loading reduction is caused by volatiles passing through the walls of a tubular microporous Teflon PTFE membrane. The argon gas removes the solvent vapour from the exterior of the membrane. Solvent-free analytes remain inside the membrane and are carried to the plasma for atomisation and excitation. [Pg.39]

In atomic emission spectroscopy, the radiation source is the sample itself. The energy for excitation of analyte atoms is supplied by a plasma, a flame, an oven, or an electric arc or spark. The signal is the measured intensity of the source at the wavelength of interest. In atomic absorption spectroscopy, the radiation source is usually a line source such as a hollow cathode lamp, and the signal is the absorbance. The latter is calculated from the radiant power of the source and the resulting power after the radiation has passed through the atomized sample. [Pg.1097]

Atomic emission The emission of radiation by atoms that have been excited in a plasma, a flame, or an electric arc or spark. Atomic emission spectroscopy (AES) An analytical method based on atomic emission. [Pg.1103]

Dashpot Synonymous with air damper in an analytical balance, dc Plasma (DCP) spectroscopy A method that makes use of an electrically induced argon plasma to excite the emission spectra of analyte species. [Pg.1106]


See other pages where Excitation plasma emission spectroscopy is mentioned: [Pg.773]    [Pg.38]    [Pg.38]    [Pg.12]    [Pg.16]    [Pg.687]    [Pg.395]    [Pg.19]    [Pg.5]    [Pg.435]    [Pg.446]    [Pg.323]    [Pg.317]    [Pg.15]    [Pg.47]    [Pg.76]    [Pg.114]    [Pg.7]    [Pg.228]    [Pg.17]    [Pg.468]    [Pg.202]    [Pg.415]    [Pg.416]    [Pg.205]    [Pg.317]    [Pg.347]    [Pg.18]    [Pg.22]    [Pg.745]    [Pg.745]    [Pg.840]   