Perhaps the most common type of problem encountered in the analytical lab is a quantitative analysis. Examples of typical quantitative analyses include the elemental analysis of a newly synthesized compound, measuring the concentration of glucose in blood, or determining the difference between the bulk and surface concentrations of Cr in steel. Much of the analytical work in clinical, pharmaceutical, environmental, and industrial labs involves developing new methods for determining the concentration of targeted species in complex samples. Most of the examples in this text come from the area of quantitative analysis. [Pg.9]

Selectivity Due to the narrow width of absorption lines, atomic absorption provides excellent selectivity. Atomic absorption can be used for the analysis of over 60 elements at concentrations at or below the level of parts per million. [Pg.422]

Chemical Properties. Elemental analysis, impurity content, and stoichiometry are determined by chemical or iastmmental analysis. The use of iastmmental analytical methods (qv) is increasing because these ate usually faster, can be automated, and can be used to determine very small concentrations of elements (see Trace AND RESIDUE ANALYSIS). Atomic absorption spectroscopy and x-ray fluorescence methods are the most useful iastmmental techniques ia determining chemical compositions of inorganic pigments. Chemical analysis of principal components is carried out to determine pigment stoichiometry. Analysis of trace elements is important. The presence of undesirable elements, such as heavy metals, even in small amounts, can make the pigment unusable for environmental reasons. [Pg.4]

Only slightly less accurate ( 0.3—0.5%) and more versatile in scale are other titration techniques. Plutonium maybe oxidized in aqueous solution to PuO " 2 using AgO, and then reduced to Pu" " by a known excess of Fe", which is back-titrated with Ce" ". Pu" " may be titrated complexometricaHy with EDTA and a colorimetric indicator such as Arsenazo(I), even in the presence of a large excess of UO " 2- Solution spectrophotometry (Figs. 4 and 5) can be utilized if the plutonium oxidation state is known or controlled. The spectrophotometric method is very sensitive if a colored complex such as Arsenazo(III) is used. Analytically usehil absorption maxima and molar absorption coefficients ( s) are given in Table 10. Laser photoacoustic spectroscopy has been developed for both elemental analysis and speciation (oxidation state) at concentrations of lO " — 10 M (118). Chemical extraction can also be used to enhance this technique. [Pg.200]

Electron Probe X-Ray Microanalysis (EPMA) is a spatially resolved, quantitative elemental analysis technique based on the generation of characteristic X rays by a focused beam of energetic electrons. EPMA is used to measure the concentrations of elements (beryllium to the actinides) at levels as low as 100 parts per million (ppm) and to determine lateral distributions by mapping. The modern EPMA instrument consists of several key components ... [Pg.175]

The chlorine content can be determined by either chlorine elemental analysis or a potentiometric titration using a chloride-ion electrode. For titration, about 0.2 g. of polymer is heated in 3 ml. of pyridine at 100° for 2 hours. This suspension is then transferred to a 50-mi. beaker containing 30 ml. of aqueous 50% acetic acid and 5 ini. of concentrated nitric acid, and the resulting mixture is titrated against aqueous 0.1 N silver nitrate. [Pg.98]

J.9 You are asked to identify compound X, which was extracted from a plant seized by customs inspectors. You run a number of tests and collect the following data. Compound X is a white, crystalline solid. An aqueous solution of X turns litmus red and conducts electricity poorly, even when X is present at appreciable concentrations. When you add sodium hydroxide to the solution a reaction takes place. A solution of the products of the reaction conducts electricity well. An elemental analysis of X shows that the mass percentage composition of the compound is 26.68% C and 2.239% H, with the remainder being oxygen. A mass spectrum of X yields a molar mass of 90.0 g-moF. (a) Write the empirical formula of X. (b) Write... [Pg.101]

The TEM images of 12 wt.% Co/MgO calcined at 873 K (Catalyst I) before and after reduction are shown in Fig. 1 (a) and (b), respectively. Although Co metal phase was detected in reduced Co/MgO by X-ray diffraction measurements (XRD) [7, 8], no Co metal particle was observed on both catalysts. EDS elemental analysis showed that primary particles contain both Mg and Co elements, whose concentrations were about the same as loaded amounts. Figure 2 shows TEM image of 12 wt.% Co/MgO calcined at 1173 K (Catalyst II). [Pg.518]

Trends in element analysis are multi-element (survey) analysis, lower concentration levels, micro/local element analysis and speciation (coupling with chromatography). An overview of the determination of elements in polymeric materials is available [7], Reviews on sample preparation for trace analysis are given in refs [8-10]. Quality assurance of analytical data in routine elemental analysis has been discussed [11], Organic analysis is obviously much more requested in relation to polymer/additive matrices than elemental analysis. [Pg.591]

Applications X-ray fluorescence is widely used for direct examination of polymeric materials (analysis of additives, catalyst residues, etc.) from research to recycling, through production and quality control, to troubleshooting. Many problems meet the concentration range in which conventional XRF is strong, namely from ppm upwards. Table 8.42 is merely indicative of the presence of certain additive classes corresponding to elemental analysis element combinations are obviously more specific for a given additive. It should be considered that some 60 atomic elements may be found in polymeric formulations. The XRF technique does not provide any structural information about the analytes detected the technique also has limited utility when... [Pg.634]

Applications ICP-MS has become the technique of choice for the determination of elements in a wide range of liquid samples at concentrations in the ng L 1 to [igL-1 range. Typical applications of ICP-MS are multi-element analysis of liquids (even with high solid contents) element speciation by hyphenation to chromatographic techniques continuous on-line gas analysis multi-element trace analysis of polymers and trace analysis in high-purity materials. ICP-MS is routinely used for quality control purposes. [Pg.658]

Principles and Characteristics The fastest growing area in elemental analysis is in the use of hyphenated techniques for speciation measurement. Elemental spe-ciation analysis, defined as the qualitative identification and quantitative determination of the individual chemical forms that comprise the total concentration of an element in a sample, has become an important field of research in analytical chemistry. Speciation or the process yielding evidence of the molecular form of an analyte, has relevance in the fields of food, the environment, and occupational health analysis, and involves analytical chemists as well as legislators. The environmental and toxicological effects of a metal often depend on its forms. The determination of the total metal content... [Pg.674]

If we consider only a few of the general requirements for the ideal polymer/additive analysis techniques (e.g. no matrix interferences, quantitative), then it is obvious that the choice is much restricted. Elements of the ideal method might include LD and MS, with reference to CRMs. Laser desorption and REMPI-MS are moving closest to direct selective sampling tandem mass spectrometry is supreme in identification. Direct-probe MS may yield accurate masses and concentrations of the components contained in the polymeric material. Selective sample preparation, efficient separation, selective detection, mass spectrometry and chemometric deconvolution techniques are complementary rather than competitive techniques. For elemental analysis, LA-ICP-ToFMS scores high. [Pg.744]

Due to the low solubility of the monomer 1III) in benzene, the polymerization had to be carried out at less than 10% (w/v) monomer concentration. A yield of 92% was obtained by AIBN initiation at 60°C. Ammonium persulfate and benzoyl peroxide initiators were found to be ineffective. The solubility characteristics of poly(N-pheny1-3,4-dimethylenepyrroline) are listed in Table I. The polymer was insoluble in most common solvents except for formic acid and trifluoroacetic acid. The polymer was characterized by C,H elemental analysis, IR and NMR. [Pg.131]

The impedance spectroscopy of steel corrosion in concentrated HC1, with and without inhibitors, exhibit relatively straightforward electrochemical phenomenology and can be represented by simple equivalent circuits involving primarily passive electrical elements. Analysis of these circuits for steel corroding in HC1 per se reveals that the heterogeneity of the surface is established rapidly and can be simulated with a simple electrical circuit model. [Pg.648]

Thus the results from elution chromatography, extraction with acid and base and elemental analysis show that as the catalyst concentration used increases, the heteroatom content of the resultant oil decreases. [Pg.272]


See other pages where Elemental analysis concentration is mentioned: [Pg.1324]    [Pg.1800]    [Pg.50]    [Pg.276]    [Pg.423]    [Pg.208]    [Pg.18]    [Pg.172]    [Pg.368]    [Pg.368]    [Pg.156]    [Pg.15]    [Pg.22]    [Pg.121]    [Pg.301]    [Pg.347]    [Pg.500]    [Pg.617]    [Pg.438]    [Pg.170]    [Pg.7]    [Pg.152]    [Pg.63]    [Pg.447]    [Pg.42]    [Pg.610]    [Pg.92]    [Pg.447]    [Pg.350]    [Pg.504]    [Pg.296]    [Pg.119]    [Pg.279]    [Pg.271]   
See also in sourсe #XX -- [ Pg.12 ]




SEARCH



Elemental concentration calculation activation analysis

Elemental concentrations

Elements concentration

Quantitative analysis of rare earth element with simulated concentration

© 2024 chempedia.info