Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Electrospray ionization . See

The advent of atmospheric-pressure ionization (API) provided a method of ionizing labile and nonvolatile substances so that they could be examined by mass spectrometry. API has become strongly linked to HPLC as a basis for ionizing the eluant on its way into the mass spectrometer, although it is also used as a stand-alone inlet for introduction of samples. API is important in thermospray, plasmaspray, and electrospray ionization (see Chapters 8 and 11). [Pg.61]

One problem with GC-MS, in addition to being labor intensive and having particularly long analysis times, was that higher molecular weight (molar mass) components or compounds with preformed cations (such as cholines or carnitine) are easily hydrolyzed and cannot be analyzed effectively using GC-MS. With the advent of new ionization techniques for LC effluents (see Section 4.1.2), such as electrospray ionization (see Section 2.1.15), more volatile and larger molecular mass compounds could be analyzed,... [Pg.288]

For a description of commercially available spectrometers designed specifically for electrospray ionization, see L, Vorees. Anal. Chem.. 1994, 66. -i81,A, For spectrometers combining electrospray with TOF mass analvz-ers, see C. M. Henr, Anal. Chem.. 1999,197a,... [Pg.289]

For a more detailed description of the ionization process inherent in electrospray, please see Chapter 9, which discusses atmospheric pressure ionization (API), The reader also should compare electrospray with thermospray (see Chapter 11). [Pg.55]

Aerosols can be produced as a spray of droplets by various means. A good example of a nebulizer is the common household hair spray, which produces fine droplets of a solution of hair lacquer by using a gas to blow the lacquer solution through a fine nozzle so that it emerges as a spray of small droplets. In use, the droplets strike the hair and settle, and the solvent evaporates to leave behind the nonvolatile lacquer. For mass spectrometry, a spray of a solution of analyte can be produced similarly or by a wide variety of other methods, many of which are discussed here. Chapters 8 ( Electrospray Ionization ) and 11 ( Thermospray and Plasmaspray Interfaces ) also contain details of droplet evaporation and formation of ions that are relevant to the discussion in this chapter. Aerosols are also produced by laser ablation for more information on this topic, see Chapters 17 and 18. [Pg.138]

Electrospray ionization occurs by the same four steps as listed above for thermospray (see Section 4.6). In contrast to thermospray, and most other ionization methods nsed in mass spectrometry, it shonld be noted that electrospray ionization nnnsnally takes place at atmospheric pressure. A similar process carried out under vacuum is known as electrohydrodynamic ionization and gives rise to qnite different analytical results. This technique has not been developed into a commercial LC-MS interface and will not be considered further. [Pg.158]

See footnote cto Table3 LC/PB/MS = hquid chromatography/particle beam mass spectrometry LC/APcl/ESl-MS/MS = liquid chromtography/atmospheric pressure chemical ionization/electrospray ionization tandem mass spectrometry LC/FTIR = Fourier transform infrared LC/TSP-MS/MS = liquid chromatography/thermospray tandem mass spectrometry LC/TSP-MS = liquid chromatography/thermospray mass spectrometry. [Pg.423]

Notes Peptide fragments detected using MALDI and electrospray ionization (ESI)-MS. For more detail, please see Reference 33. [Pg.342]

D1 (10,17S-docosatriene) from DHA using tandem liquid chromatography-photodiode array-electrospray ionization-tandem mass spectrometry (LC-PDA-ESI-MS-MS)-based lipidomic analysis have been documented in ischemic brain [4] and retinal pigment epithelium [5], This new lipid is called neuroprotectin D1 (1) because of its neuro-protectiveproperties in brain ischemia-reperfusion [4] and in oxidative stress-challenged retinal pigment epithelial cells [5] (2) because of its potent ability to inactivate proapoptotic signaling (see apoptosis, Ch. 35) [5] and (3) because it is the first identified neuroprotective mediator derived from DHA. [Pg.577]

The method of ionization, as electrospray ionization, ESI (see Chapter 2, Section 2.1.15) tends to promote multiple ionization, which is not as frequent in matrix-assisted laser desorption/ionization, MALDI (see Section 2.1.22) method. [Pg.180]

In addition to the dissolved elements and compounds in the oceanic water column, a wide variety of water column chemicals are found in marine organisms and organic detritus. For example, a milliliter of surface seawater can contain on the order of 10 million viruses, 1 million bacteria, 100,000 phytoplankton, and 10,000 zooplankton [9]. With the advent of soft ionization processes for mass spectrometry systems, scientists have been able to study these marine organisms at molecular level. The use of electrospray ionization (ESI see Section 2.1.15), atmospheric pressure chemical ionization... [Pg.239]


See other pages where Electrospray ionization . See is mentioned: [Pg.231]    [Pg.41]    [Pg.589]    [Pg.63]    [Pg.231]    [Pg.41]    [Pg.589]    [Pg.63]    [Pg.163]    [Pg.1029]    [Pg.77]    [Pg.81]    [Pg.119]    [Pg.123]    [Pg.192]    [Pg.219]    [Pg.227]    [Pg.244]    [Pg.63]    [Pg.243]    [Pg.310]   


SEARCH



Electrospray ionization

Electrospray ionization mass spectrometry . See

© 2024 chempedia.info