Electrodes of the Second Kind An electrode of the first kind involving an M"+/M redox couple will respond to the concentration of another species if that species is in equilibrium with M"+. For example, the potential of a silver electrode in a solution of Ag+ is given by... [Pg.474]

When the potential of an electrode of the first kind responds to the potential of another ion that is in equilibrium with M"+, it is called an electrode of the second kind. Two common electrodes of the second kind are the calomel and silver/silver chloride reference electrodes. Electrodes of the second kind also can be based on complexation reactions. Eor example, an electrode for EDTA is constructed by coupling a Hg +/Hg electrode of the first kind to EDTA by taking advantage of its formation of a stable complex with Hg +. [Pg.475]

Redox Electrodes Electrodes of the first and second kind develop a potential as the result of a redox reaction in which the metallic electrode undergoes a change in its oxidation state. Metallic electrodes also can serve simply as a source of, or a sink for, electrons in other redox reactions. Such electrodes are called redox electrodes. The Pt cathode in Example 11.1 is an example of a redox electrode because its potential is determined by the concentrations of Ee + and Ee + in the indicator half-cell. Note that the potential of a redox electrode generally responds to the concentration of more than one ion, limiting their usefulness for direct potentiometry. [Pg.475]

The relative measurement error in concentration, therefore, is determined by the magnitude of the error in measuring the cell s potential and by the charge of the analyte. Representative values are shown in Table 11.7 for ions with charges of+1 and +2, at a temperature of 25 °C. Accuracies of 1-5% for monovalent ions and 2-10% for divalent ions are typical. Although equation 11.22 was developed for membrane electrodes, it also applies to metallic electrodes of the first and second kind when z is replaced by n. [Pg.495]

Potentiometric electrodes are divided into two classes metallic electrodes and membrane electrodes. The smaller of these classes are the metallic electrodes. Electrodes of the first kind respond to the concentration of their cation in solution thus the potential of an Ag wire is determined by the concentration of Ag+ in solution. When another species is present in solution and in equilibrium with the metal ion, then the electrode s potential will respond to the concentration of that ion. Eor example, an Ag wire in contact with a solution of Ck will respond to the concentration of Ck since the relative concentrations of Ag+ and Ck are fixed by the solubility product for AgCl. Such electrodes are called electrodes of the second kind. [Pg.532]

Electrodes such as Cu VCu which are reversible with respect to the ions of the metal phase, are referred to as electrodes of the first kind, whereas electrodes such as Ag/AgCl, Cl" that are based on a sparingly soluble salt in equilibrium with its saturated solution are referred to as electrodes of the second kind. All reference electrodes must have reproducible potentials that are defined by the activity of the species involved in the equilibrium and the potential must remain constant during, and subsequent to, the passage of small quantities of charge during the measurement of another potential. [Pg.1246]

The Ag/AgCl, Cl" electrode, which may be regarded as typical of electrodes of the second kind, consists of AgCl in contact with a soluble chloride, usually KCl. This electrode is essentially an Ag -F e Ag electrode, in which the 0 is controlled by the solubility product of AgCl and by the flci- Thus... [Pg.1247]

Metals in practice are usually coated with an oxide film that affects the potential, and metals such as Sb, Bi, As, W and Te behave as reversible A//A/,Oy/OH electrodes whose potentials are pH dependent electrodes of this type may be used to determine the solution s pH in the same way as the reversible hydrogen electrode. According to Ives and Janz these electrodes may be regarded as a particular case of electrodes of the second kind, since the oxygen in the metal oxide participates in the self-ionisation of water. [Pg.1251]

It is also possible in appropriate cases to measure by direct potentiometry the concentration of an ion which is not directly concerned in the electrode reaction. This involves the use of an electrode of the second kind , an example of which is the silver-silver chloride electrode which is formed by coating a silver wire with silver chloride this electrode can be used to measure the concentration of chloride ions in solution. [Pg.548]

Indicator electrodes for anions may take the form of a gas electrode (e.g. oxygen electrode for OH- chlorine electrode for Cl-), but in many instances consist of an appropriate electrode of the second kind thus as shown in Section 15.1, the potential of a silver-silver chloride electrode is governed by the chloride-ion activity of the solution. Selective-ion electrodes are also available for many anions. [Pg.554]

The pressed disc (or pellet) type of crystalline membrane electrode is illustrated by silver sulphide, in which substance silver ions can migrate. The pellet is sealed into the base of a plastic container as in the case of the lanthanum fluoride electrode, and contact is made by means of a silver wire with its lower end embedded in the pellet this wire establishes equilibrium with silver ions in the pellet and thus functions as an internal reference electrode. Placed in a solution containing silver ions the electrode acquires a potential which is dictated by the activity of the silver ions in the test solution. Placed in a solution containing sulphide ions, the electrode acquires a potential which is governed by the silver ion activity in the solution, and this is itself dictated by the activity of the sulphide ions in the test solution and the solubility product of silver sulphide — i.e. it is an electrode of the second kind (Section 15.1). [Pg.560]

Depending on electrolyte composition, the metal will either dissolve in the anodic reaction, that is, form solution ions [reaction (1.24)], or will form insoluble or poorly soluble salts or oxides precipitating as a new solid phase next to the electrode surface [reaction (1.28)]. Reacting metal electrodes forming soluble products are also known as electrodes of the first kind, and those forming solid products are known as electrodes of the second kind. [Pg.16]

The potential of an electrode of the second kind is determined by the activity (concentration) of anions, or more correctly, by the mean ionic activity of the corresponding electrolyte [see Eq. (3.50)]. The most conunon among electrodes of this type are the calomel REs. In them, a volume of mercury is in contact with KCl solution which has a well-defined concentration and is saturated with calomel Hg2Cl2, a poorly soluble mercury salt. The value of such an electrode is 0.2676 V (aU numerical values refer to 25°C, and potentials are reported on the SHE scale). Three types of calomel electrode are in practical use they differ in KCl concentration and, accordingly, in the values of ionic activity and potential ... [Pg.194]

When the metal is in contact with an electrolyte solution not containing its ions, its equilibrium potential theoretically will be shifted strongly in the negative direction. However, before long a certain number of ions will accumulate close to the metal surface as a result of spontaneous dissolution of the metal. We may assume, provisionally, that the equilibrium potential of such an electrode corresponds to a concentration of ions of this metal of about 10 M. In the case of electrodes of the second kind, the solution is practically always saturated with metal ions, and their potential corresponds to the given anion concentration [an equation of the type (3.35)]. When required, a metal s equilibrium potential can be altered by addition of complexing agents to the solution (see Eq. (3.37)]. [Pg.297]

An electrode of the second kind consists of a metal whose surface is reversibly in contact or coated with one of its compounds (also containing the anion under test) that is sparingly soluble in the contact solution. [Pg.62]

Although not essential, one often uses a previously coated AgCl-Ag electrode or a silver-plated Pt wire coated electrolytically in KC1 solution with a thin deposit of AgCl. Such dry AgCl-Ag electrodes are much in favour as reference electrodes (although in the absence of oxidants), in addition to calomel electrodes (Pt wire in contact with Hg, covered with calomel paste in contact with KC1 solution), which also belong to the second kind, viz.,... [Pg.63]

Electrodes of the first kind have only limited application to titration in non-aqueous media a well-known example is the use of a silver electrode in the determination of sulphides and/or mercaptans in petroleum products by titration in methanol-benzene (1 1) with methanolic silver nitrate as titrant. As an indicator electrode of the second kind the antimony pH electrode (or antimony/antimony trioxide electrode) may be mentioned its standard potential value depends on proton solvation in the titration medium chosen cf., the equilibrium reaction on p. 46). [Pg.304]

The fact that the water molecules forming the hydration sheath have limited mobility, i.e. that the solution is to certain degree ordered, results in lower values of the ionic entropies. In special cases, the ionic entropy can be measured (e.g. from the dependence of the standard potential on the temperature for electrodes of the second kind). Otherwise, the heat of solution is the measurable quantity. Knowledge of the lattice energy then permits calculation of the heat of hydration. For a saturated solution, the heat of solution is equal to the product of the temperature and the entropy of solution, from which the entropy of the salt in the solution can be found. However, the absolute value of the entropy of the crystal must be obtained from the dependence of its thermal capacity on the temperature down to very low temperatures. The value of the entropy of the salt can then yield the overall hydration number. It is, however, difficult to separate the contributions of the cation and of the anion. [Pg.33]

In practice, it is very often necessary to determine the potential of a test (indicator) electrode connected in a cell with a well defined second electrode. This reference electrode is usually a suitable electrode of the second kind, as described in Section 3.2.2. The potentials of these electrodes are tabulated, so that Eq. (3.1.66) can be used to determine the potential of the test electrode from the measured EMF. The standard hydrogen electrode is a hydrogen electrode saturated with gaseous hydrogen with a partial pressure equal to the standard pressure and immersed in a solution with unit hydrogen ion activity. Its potential is set equal to zero by convention. Because of the relative difficulty involved in preparing this electrode and various other complications (see Section 3.2.1), it is not used as a reference electrode in practice. [Pg.177]

Electrodes of the second kind. These electrodes consist of three phases. The metal is covered by a layer of its sparingly soluble salt, usually with the character of a solid electrolyte, and is immersed in a solution containing the anions of this salt. The solution contains a soluble salt of this anion. Because of the two interfaces, equilibrium is established between the metal atoms and the anions in solution through two partial equilibria between the metal and its cation in the sparingly soluble salt and between the anion in the solid phase of the sparingly soluble salt and the anion in solution (see Eqs (3.1.24), (3.1.26) and (3.1.64)). [Pg.181]

When eliminating the liquid junction potential by one of the methods described in Section 2.5.3, we obtain a concentration cell without transport. The value of its EMF is given simply by the difference between the two electrode potentials. More exactly than by the described elimination of the liquid junction potential, a concentration cell without transport can be obtained by using amalgam electrodes or electrodes of the second kind. [Pg.182]

Anionic electrodes of the first kind are rarely used in practice other, more important, sorts of electrode exhibiting a reversible response to anions are the electrodes of the second kind. [Pg.186]

The expression for the potential of electrodes of the second kind on the hydrogen scale can be derived from the affinity of the reaction occurring in a cell with a standard hydrogen electrode. For example, for the silver chloride electrode with the half-cell reaction... [Pg.186]

The same expression is obtained if electrodes of the second kind are considered as electrodes of the first kind, where the activity of the metal cations depends on the solubility product of the given insoluble salt (cf. Eq. 3.1.26) ... [Pg.186]

Table 3.4 Standard potentials of electrodes of the second kind. (From the CRC Handbook of Chemistry and Physics, recalculated to the standard pressure 102 kPa)... Table 3.4 Standard potentials of electrodes of the second kind. (From the CRC Handbook of Chemistry and Physics, recalculated to the standard pressure 102 kPa)...
The silver chloride electrode is preferable for precise measurements. The standard potentials of some electrodes of the second kind are listed in Table 3.4. Various electrode constructions are shown in Fig. 3.8. [Pg.188]

In addition to their use as reference electrodes in routine potentiometric measurements, electrodes of the second kind with a saturated KC1 (or, in some cases, with sodium chloride or, preferentially, formate) solution as electrolyte have important applications as potential probes. If an electric current passes through the electrolyte solution or the two electrolyte solutions are separated by an electrochemical membrane (see Section 6.1), then it becomes important to determine the electrical potential difference between two points in the solution (e.g. between the solution on both sides of the membrane). Two silver chloride or saturated calomel electrodes are placed in the test system so that the tips of the liquid bridges lie at the required points in the system. The value of the electrical potential difference between the two points is equal to that between the two probes. Similar potential probes on a microscale are used in electrophysiology (the tips of the salt bridges are usually several micrometres in size). They are termed micropipettes (Fig. 3.8D.)... [Pg.188]

The interfacial tension always depends on the potential of the ideal polarized electrode. In order to derive this dependence, consider a cell consisting of an ideal polarized electrode of metal M and a reference non-polarizable electrode of the second kind of the same metal covered with a sparingly soluble salt MA. Anion A is a component of the electrolyte in the cell. The quantities related to the first electrode will be denoted as m, the quantities related to the reference electrode as m and to the solution as 1. For equilibrium between the electrons and ions M+ in the metal phase, Eq. (4.2.17) can be written in the form (s = n — 2)... [Pg.217]

Anodic oxidation often involves the formation of films on the surface, i.e. of a solid phase formed of salts or complexes of the metals with solution components. They often appear in the potential region where the electrode, covered with the oxidation product, can function as an electrode of the second kind. Under these conditions the films are thermodynamically stable. On the other hand, films are sometimes formed which in view of their solubility product and the pH of the solution should not be stable. These films are stabilized by their structure or by the influence of surface forces at the interface. [Pg.388]

Thus films can be divided into two groups according to their morphology. Discontinuous films are porous, have a low resistance and are formed at potentials close to the equilibrium potential of the corresponding electrode of the second kind. They often have substantial thickness (up to 1 mm). Films of this kind include halide films on copper, silver, lead and mercury, sulphate films on lead, iron and nickel oxide films on cadmium, zinc and magnesium, etc. Because of their low resistance and the reversible electrode reactions of their formation and dissolution, these films are often very important for electrode systems in storage batteries. [Pg.388]

Silver halide electrodes (with properties similar to electrodes of the second kind) are made of AgCl, AgBr and Agl. These electrodes, containing also Ag2S, are used for the determination of Cl-, Br, I and CN ions in various inorganic and biological materials. [Pg.442]

It follows that metal electrodes of the second kind not only serve as indicator electrodes for their own cations but also react to changes in metal ion activity resulting from precipitation or complexation reactions. For example, a Cl- ion electrode responds to the activity of the... [Pg.633]


See other pages where Second kind electrode is mentioned: [Pg.475]    [Pg.532]    [Pg.771]    [Pg.220]    [Pg.45]    [Pg.193]    [Pg.297]    [Pg.399]    [Pg.655]    [Pg.305]    [Pg.306]    [Pg.306]    [Pg.186]    [Pg.49]    [Pg.94]   
See also in sourсe #XX -- [ Pg.133 , Pg.192 ]

See also in sourсe #XX -- [ Pg.298 ]

See also in sourсe #XX -- [ Pg.229 , Pg.261 , Pg.264 , Pg.268 ]




SEARCH



Electrode kinds

Second kind

© 2024 chempedia.info