Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Dextrans limit

ADDITIVITY PRINCIPLE LIMIT DEXTRAN LIMITING ISOTOPE EFFECT Limits,... [Pg.756]

The DCC assay is dependent upon the capacity of charcoal to adsorb free hormone, whereas the addition of dextran limits the absorption of the hormone-receptor complex by the charcoal (K14). By using increasing concentrations of radiolabeled hormone and a concurrent range of unlabeled hormone competitors, titration of the receptor to a saturation end point occurs. [Pg.203]

Hydrophilic gels in bead form Dextran Limitations in flow rate due to compressibility, low non-specific adsorption Sephadex, AP Biotech... [Pg.302]

Biopolymer Extraction. Research interests involving new techniques for separation of biochemicals from fermentation broth and cell culture media have increased as biotechnology has grown. Most separation methods are limited to small-scale appHcations but recendy solvent extraction has been studied as a potential technique for continuous and large-scale production and the use of two-phase aqueous systems has received increasing attention (259). A range of enzymes have favorable partition properties in a system based on a PGE—dextran—salt solution (97) ... [Pg.80]

It is found that the validity of system suitability test depends on loading of dextran standai d. Chai acteristics for loading 3 was close to the middle of prescribed interval, for loading 2 it is close to the upper limit, for loading 1 it is outside of the limit. [Pg.345]

The selective separation range of P-6/S-200 was determined with Blue Dextran (Vexdi exclusion limit) and fructose (V,o total permeation limit). Molecular weight (degree of polymerization) calibration (Fig. 16.22) was established with dextran standards and low dp pullulans (dp 3, 6, 9, 12, 15, 18) formed by the controlled hydrolysis of high dp pullulan. [Pg.486]

There are two types of stationary phases commonly used in exclusion chromatography silica gel and micro-reticulated cross-linked polystyrene gels. A third type of exclusion media is comprised of the Dextran gels. Dextran gels are produced by the action of certain bacteria on a sucrose substrate. They consist of framework of glucose units that can form a gel in aqueous solvents that have size exclusion properties. Unfortunately the gels are mechanically weak and thus, cannot tolerate the high pressures necessary for HPLC and, as a consequence, are of very limited use to the analyst. [Pg.283]

Adsorbents for biomacromolecules such as proteins have special properties. First, they need to have large pore sizes. A ratio of pore radius to molecule radius larger than 5 is desirable to prevent excessive diffusional hindrance (see Intraparticle Mass Transfer in this section). Thus, for typical proteins, pore radii need to be in excess of 10-15 nm. Second, functional groups for interactions with the protein are usually attached to the adsorbent backbone via a spacer arm to provide accessibility. Third, adsorbents based on hydrophilic structures are preferred to limit nonspecific interactions with the adsorbent backbone and prevent global unfolding or denaturation of the protein. Thus, if hydrophobic supports are used, their surfaces are usually rendered hydrophilic by incorporating hydrophilic coatings such as dextran or polyvinyl alcohol. Finally, materials stable in sodium hydroxide solutions (used for clean-in-place) are... [Pg.9]

Fractionation Methods. Ultrafiltration and gel filtration are nondestructive methods which, based on limited experience, can be used for fractionation of mineral complexes from digests. In earlier studies mineral absorption on the gel material was a problem. Lonnerdal (30) introduced a method of treating dextran gels with sodium borohydride in order to eliminate the mineral-binding sites on the gel. In preliminary studies we have recovered more than 90 of Ca, Mg, Fe, Zn and P in samples applied to a borohydride-treated gel column (Sephadex G-50, Pharmacia Fine Chemicals, Piscataway, NJ). Recovery of Ca (Table IV) and Mg, Fe and Zn from ultrafiltration was also good. [Pg.19]

Because of the limitations of silica, several manufacturers offer SEC columns based on hydrophilic organic polymer. These include polymethacrylate supports, proprietary hydrophilic polymers, and semirigid cross-linked agaroses and dextrans. These materials are more stable under high-pH operation. [Pg.99]


See other pages where Dextrans limit is mentioned: [Pg.315]    [Pg.315]    [Pg.52]    [Pg.295]    [Pg.298]    [Pg.39]    [Pg.51]    [Pg.469]    [Pg.216]    [Pg.130]    [Pg.140]    [Pg.94]    [Pg.285]    [Pg.51]    [Pg.230]    [Pg.908]    [Pg.108]    [Pg.252]    [Pg.429]    [Pg.203]    [Pg.407]    [Pg.137]    [Pg.165]    [Pg.217]    [Pg.230]    [Pg.397]    [Pg.270]    [Pg.4]    [Pg.431]    [Pg.462]    [Pg.451]    [Pg.197]    [Pg.149]    [Pg.423]    [Pg.93]    [Pg.123]    [Pg.102]    [Pg.403]    [Pg.167]    [Pg.188]   
See also in sourсe #XX -- [ Pg.680 ]




SEARCH



Dextrins limit, from dextrans