Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Detectors chemical labeling

Another consideration when choosing a detector is whether it is important to preserve the separated analytes, either for use or for further analysis. Some methods, such as evaporative laser scattering detection and mass spectrometry, destroy the sample during the measurement. Other methods, such as fluorescence or radiochemical detection, may require chemical labeling of the analytes ... [Pg.210]

The ability to identify particular sequences of DNA, both quickly and precisely has become of increasing importance in recent years. Current DNA detection methods are limited by their need for the DNA in the sample to be chemically labelled before analysis. In this poster, the biosensor described does not. In fact, the detector is the DNA mimic, peptide nucleic acid (PNA) whilst the sensor is based on polydiacetylene (PDA) liposomes. It is envisaged that when the PNA detector binds to its target gene, the PDA sensor will be induced to change colour from blue to red. It is anticipated that this response will be detected visually and quantified through UVA/is spectroscopy. In order to improve the hydrophilic character of the liposomes, a hydrophilic spacer has been included. Here, we report our progress to date on the preparation and evaluation of PNA-functionalised PDA liposomes as potential, novel colorimetric nucleic acid biosensors. [Pg.216]

The advantage of using a mass spectrometer as the detector is associated with cases (ii) and (iii) above. In particular, because mass may be used as a discriminating feature, it is possible to use an isotopically labelled analyte as an internal standard. These have virtnally identical physical and chemical properties to the unlabelled analogue, and are therefore likely to experience similar losses during... [Pg.46]

Fig. 31 (A) Principle of a sandwich immunoassay using FDA particulate labels. The analyte is first immobilized by the capture antibody preadsorbed on the solid phase (a) and then exposed to antibody-coated microparticle labels (b). Every microparticle contains 108 FDA molecules. High signal amplification is achieved after solubilisation, release, and conversion of the precursor FDA into fluorescein molecules by the addition of DMSO and NaOH (c). (B) Calibration curves of IgG-FDA microcrystal labels with increasing surface coverage of detector antibody (a-d) compared with direct FITC-labeled detector antibody (e). The fluorescence signals increase with increasing IgG concentration. FDA microcrystals with a high IgG surface coverage (c,d) perform better than those with lower surface coverage (a,b). (Reprinted with permission from [189]. Copyright 2002 American Chemical Society)... Fig. 31 (A) Principle of a sandwich immunoassay using FDA particulate labels. The analyte is first immobilized by the capture antibody preadsorbed on the solid phase (a) and then exposed to antibody-coated microparticle labels (b). Every microparticle contains 108 FDA molecules. High signal amplification is achieved after solubilisation, release, and conversion of the precursor FDA into fluorescein molecules by the addition of DMSO and NaOH (c). (B) Calibration curves of IgG-FDA microcrystal labels with increasing surface coverage of detector antibody (a-d) compared with direct FITC-labeled detector antibody (e). The fluorescence signals increase with increasing IgG concentration. FDA microcrystals with a high IgG surface coverage (c,d) perform better than those with lower surface coverage (a,b). (Reprinted with permission from [189]. Copyright 2002 American Chemical Society)...
FIGURE 10.2 Schematic of the immunoassay chip. Notations for chip layout RB, run buffer Ab-E, enzyme-labeled antibody Ag, antigen S, substrate IRC, immunoreaction chamber B, unused reservoir. Notations for detector RE, reference electrode CE, counterelectrode WE, working electrode. The inset shows a schematic diagram of the separation of Ab-E from Ag/Ab-E complex [1009]. Reprinted with permission from the American Chemical Society. [Pg.339]

The availability of an on-line radioisotope detector for CE is especially appealing for several reasons. First, state-of-the-art radiation detection technology offers extremely high sensitivity. Second, radioisotope detection affords unrivaled selectivity because only radiolabeled sample components yield a response at the detector. Third, the radiolabeled molecule possesses the same chemical properties as the un-labeled molecule, thereby permitting tracer studies. Fourth, radioisotope detection can be directly calibrated to provide a measurement of absolute concentration of the labeled species. Finally, a capillary electrophoresis system in which radioactivity detection is coupled with more conventional detectors adds extra versatility to this new separation technique. [Pg.61]

Direct searches for superheavy elements in the U+ U reaction were undertaken at the unilac by several groups. All these efforts remained without positive evidence. The data are summarized in Figure 13. The curve labeled chem [106] was obtained with off-line chemical separations [107] and an assay for a-and spontaneous fission activities here, the 10 picobam level was reached for half-lives between several days and years. Attempts to detect short-lived nuclides were less sensitive. The curve labeled gas holds for an on-line search [108] for components volatile at room temperature. wheel [106] refers to fission track detection in the unseparated product mixture deposited on a rotating catcher, rec [109] to implantation of recoil atoms in a surface barrier detector, and JET to on-line transport from target to detector with a gas jet [91,110],... [Pg.311]

The essential apparatus for pressure measurement and analysis, and other important aspects such as furnaces and temperature control, are reviewed for thermal, photochemical and radiochemical systems. The latter two also involve sources of radiation, filters and actinometry or dosimetry. There are three main analytical techniques chemical, gas chromatographic and spectroscopic. Apart from the almost obsolete method of analysis by derivative formation, the first technique is also concerned with the use of traps to indicate the presence of free radicals and provide an effective measure of their concentration. Isotopes may be used for labelling and producing an isotope effect. Easily the most important analytical technique which has a wide application is gas chromatography (both GLC and Gsc). Intrinsic problems are those concerned with types of carrier gases, detectors, columns and temperature programming, whereas sampling methods have a direct role in gas-phase kinetic studies. Identification of reactants and products have to be confirmed usually by spectroscopic methods, mainly IR and mass spectroscopy. The latter two are also used for direct analysis as may trv, visible and ESR spectroscopy, nmr spectroscopy is confined to the study of solution reactions... [Pg.1]

The use of cobalt radiation treatments for cancerous tumors was described in Example 26-3. Several other nuclides are used as radioactive tracers in medicine. Radioisotopes of an element have the same chemical properties as stable isotopes of the same element, so they can be used to label the presence of an element in compounds. A radiation detector can be used to follow the path of the element throughout the body. Modern computer-based techniques allow construction of an image of the area of the body where the radioisotope is concentrated. Salt solutions containing "iNa can be injected into the bloodstream to follow the flow of blood and locate obstructions in the circulatory system. Thallium-201 tends to concentrate in healthy heart tissue, whereas technetium-99 concentrates in abnormal heart tissue. The two can be used together to survey damage from heart disease. [Pg.1019]

Acridinium ester used as a chemiluminescent tracer. Labeled acridinium ester in the presence of alkaline hydrogen peroxide undergoes chemical changes producing light that is detected at 430 nm by a photomultiplier detector. [Pg.131]

Before considering detector characteristics and some recent developments in chemiluminescence detection, it should be noted that analytical applications of chemiluminescence involve two types of chemiluminescent response. In the first type, the chemiluminescent molecule is used as a detection label and is, therefore, present in limiting concentration relative to the reagents used to initiate the chemiluminescent reaction. The chemical reaction will therefore be pseudo first order. The slowest process in the sequence of events leading to light emission is the reaction itself, e.g., hydrolysis, bond-breaking, and rearrangements. From Eq. [Pg.106]


See other pages where Detectors chemical labeling is mentioned: [Pg.210]    [Pg.210]    [Pg.218]    [Pg.817]    [Pg.930]    [Pg.954]    [Pg.65]    [Pg.8]    [Pg.120]    [Pg.222]    [Pg.227]    [Pg.24]    [Pg.601]    [Pg.1806]    [Pg.211]    [Pg.249]    [Pg.94]    [Pg.270]    [Pg.100]    [Pg.115]    [Pg.240]    [Pg.9]    [Pg.550]    [Pg.19]    [Pg.250]    [Pg.1435]    [Pg.3090]    [Pg.3095]    [Pg.160]    [Pg.36]    [Pg.495]    [Pg.275]    [Pg.223]    [Pg.109]    [Pg.476]    [Pg.278]   
See also in sourсe #XX -- [ Pg.210 ]




SEARCH



Chemicals labelling

Chemicals labels

Chemicals, labeling

© 2024 chempedia.info