Curve Scanner

IP s have different parameters than x-ray films and so must be used in different ways. The system scanner-IP in the case at hand has a different characteristic curve. To make comparisons, one must have a conversion of the obtained grey scale values into the intensity values supplied by the film-light box system. [Pg.473]

Figure 2. Calibration curve for the Daresbury Optronics P-1000 microdensitometer by using Ilford Industrial G x-ray film. The figures above the data points indicate the nominal optical density of each measurement, assuming that a scanner reading of 255 corresponds to three optical density units. Figure 2. Calibration curve for the Daresbury Optronics P-1000 microdensitometer by using Ilford Industrial G x-ray film. The figures above the data points indicate the nominal optical density of each measurement, assuming that a scanner reading of 255 corresponds to three optical density units.
To evaluate the separate fractions two methods are available. Vertical dividing lines can be dropped from each trough of the curve to the base line, but this ignores the overlapping of the fractions (which varies since not all the fractions are equally widely separated). However, this method gives easily reproducible results, and since its inherent inaccuracy is not out of proportion to the other inaccuracies of the quantitation, it is commonly used (indeed, it is used for all automatic scanners). The alternative (M9) is to construct, within the framework of the complete... [Pg.58]

Initially this technique was intended purely as a high-resolution imaging device, down to the sub-nanometre level (Alessandrini and Facci, 2005). However, it was soon adapted for measuring the interactive forces in a process known as force spectroscopy. In this process, the sample is moved towards the tip and then retracted, with the vertical displacement of the Piezoelectric scanner being recorded. This produces voltage data recorded by the photo detector as a function of the displacement of the Piezoelectric stage. A force curve can be produced from this which provides information about the interactions between the tip of the probe and the sample. This force data can be interpreted to... [Pg.34]

The new scanner is thin, ultra-light-weight and flexible, is suitable for mobile electronics and could be easily carried in a pocket. Because it can be bent to completely cover the bent page of an open book, it would be suitable for recording fragile, historically invaluable documents or other curved images, for example the labels of wine bottles (Fig. 16.10). [Pg.404]

Fig. 16.10. Because the new scanner is mechanically flexible, it can be bent to cover curved surfaces such as labels of wine bottles. Fig. 16.10. Because the new scanner is mechanically flexible, it can be bent to cover curved surfaces such as labels of wine bottles.
Calibration is necessary for in-situ spectrometry in TLC. Either the peak height or the peak area data are measured, and used for calculation. Although the nonlinear calibration curve with an external standard method is used, however, it shows only a small deviation from linearity at small concentrations [94.95 and fulfils the requirement of routine pharmaceutical analysis 96,97J. One problem may be the saturation function of the calibration curve. Several linearisation equations have been constructed, which serve to calculate the point of determination on the basis of the calibration line and these linearisation equations are used in the software of some scanners. A more general problem is the saturation function of the calibration curve. It is a characteristic of a wide variety of adsorption-type phenomena, such as the Langmuir and the Michaelis-Menten law for enzyme kinetics as detailed in the literature [98. Saturation is also evident for the hyperbolic shape of the Kubelka-Munk equation that has to be taken into consideration when a large load is applied and has to be determined. [Pg.476]

Multidetector GPC software , a PC-DOS package written by Lesec (6), was used for triple detection GPC. For data acquisition, the personal computer is connected to the 150 CV and the CMX 100 through a CEC IEEE board (Capital Equipment Corporation, Burlington, MA) and a 199 scanner multimeter (Keithley, Cleveland, OH). Molecular weights are calculated using both the LALLS detection and the viscometric detection with a combination of the classical molecular weight calibration curve and the viscosity law of the standards (6). [Pg.170]

Indeed, after appropriate sample preparation, standards and samples can be spotted or sprayed onto the same plate, thereby providing a rapid and cost-effective analytical procedure to evaluate all sampling times. If an ultraviolet (UV) scanner is used, it is also possible to determine the amount of substance for each sample. Furthermore, the UV scanner sensitivity may be adapted specifically to analyze highly concentrated samples and poorly concentrated ones on the same plate, provided the calibration curve includes the values. As an example. Fig. 1 presents some kinetic data obtained for vitamin K, which is used as an antidote in dogs suffering from anticoagulant rodenticide poisoning [2]. The method was developed on Ci8-coated silica gel plates. Elution was based... [Pg.1162]

The scanning of a track of a developed plate by a slit-scanner yields the space dependent measuring curve of the reflectance (Fig. 6). From this curve data must be taken for calibration or for calculating the analytical result. This may be the peak-height or the integrated area under the curve. We also may produce the derivative of this curve to obtain data, or in the case of a digital system we may obtain data for approximation of the peak. [Pg.76]

Figure 2.6. Different configurations of PET scanners, (a) A circular full-ring scanner, (b) Hexagonal array of quadrant-sharing panel detectors, (c) Continuous detectors using curve plates of Nal(Tl). (Reprinted with the permission of The Cleveland Clinic Center for Medical Art Photography 2009. All Rights Reserved). Figure 2.6. Different configurations of PET scanners, (a) A circular full-ring scanner, (b) Hexagonal array of quadrant-sharing panel detectors, (c) Continuous detectors using curve plates of Nal(Tl). (Reprinted with the permission of The Cleveland Clinic Center for Medical Art Photography 2009. All Rights Reserved).
The major limitation to using CTA-SI to estimate the infarct core is the requirement that image acquisition occurs during a steady-state concentration of intravascular contrast. With the advent of faster, multidetector CT scanners, CTA imaging likely occurs during the upslope of the concentration-time curve and thus violates the steady-state assumption. It has been demonstrated that CTA-SI can significantly overestimate the DWI lesion primarily in patients with proximal artery occlusions [97]. [Pg.253]

From the vantage point of TCSPC, imaging by a piezo stage is a slow scan procedure. That means a full fluorescence decay curve is recorded in the current pixel before the scanner moves to the next one. Lifetime images can be therefore acquired by almost any TCSPC module and operation mode. Applications of onedimensional TCSPC with slow scanning are described in [76] and [74]. These... [Pg.163]

Dry the slide by purging with Ar gas and measure fluorescence intensities using a fluorescence scanner. A sigmoid curve is obtained x-axis log (concentration of an inhibitor), y-axis fluorescence intensity. [Pg.35]

The simplest theory for the analysis of surface elasticity based on AFM force-distance curve measurement is Hertzian contact mechanics [Landau and Lifshitz, 1967], As shown schematically in Figure 3.1, a force-distance curve is a plot of the displacement, z, of the piezoelectric scanner normal to the specimen s surface as the horizontal axis and the cantilever deflection, A, as the vertical axis. Hertzian contact mechanics cannot treat adhesive force in principle. We need to make some effort to minimize the adhesive force in a practical experiment. Measurement in aqueous conditions is effective for polymeric materials with low water absorbability. A cantilever with a large spring constant also hides weak van der Waals forces. Figure 3.1a shows the... [Pg.131]

Linear and cyclic voltammetric experiments were carried out by using a Metrohm E-612 scanner coupled to a Metrohm E-611 detector. Current-potential curves were recorded by a Graphtec WX-4421 X-Y recorder. A Metrohm 663 static mercury drop electrode (SMDE) with a drop area of 0.47 mm was used as working electrode for the stripping experiments. Potentials are referred to an Ag/AgCl/KCl 3 M electrode. [Pg.330]

While a 3-4 MHz curved array scanner is used for routine screening for gastric cancers, detailed examination including the evaluation of wall stratification should be performed with a high-frequency (5-9 MHz) linear probe for its superior spatial resolution. Tissue harmonic imaging is also recommended to reduce noises such as side lobe artifacts (Laing and Kurtz 1982). [Pg.135]


See other pages where Curve Scanner is mentioned: [Pg.111]    [Pg.111]    [Pg.224]    [Pg.321]    [Pg.138]    [Pg.1761]    [Pg.115]    [Pg.116]    [Pg.89]    [Pg.63]    [Pg.431]    [Pg.186]    [Pg.126]    [Pg.144]    [Pg.173]    [Pg.82]    [Pg.97]    [Pg.192]    [Pg.319]    [Pg.322]    [Pg.21]    [Pg.21]    [Pg.36]    [Pg.213]    [Pg.95]    [Pg.383]    [Pg.93]    [Pg.101]    [Pg.825]    [Pg.401]    [Pg.357]    [Pg.246]    [Pg.145]   