Chromatography HPLC detectors

The understanding of the effects of sample concentration (sample mass) in field-flow fractionation (FFF) has being obtained gradually with the improvement of the sensitivity (detection limit) of high-performance liquid chromatography (HPLC) detectors. Overloading, which was used in earlier publications, emphasizes that there is an upper limit of sample amount (or concentration) below which sample retention will not be dependent on sample mass injected into the FFF channels [1]. Recent studies show that such limits may not exist for thermal FFF (may be true for all the FFF techniques in polymer separation), although some of the most sensitive detectors on the market were used [2]. [Pg.423]

Virtually every type of high-performance liquid chromatography (HPLC) detector can be combined with SCIC refractive index, UV absorbance (direct and indirect), electrochemical, and so forth. [Pg.860]

As with gas chromatography, numerous detectors have been developed for use in monitoring HPLC separations. To date, the majority of HPLC detectors are not unique to the method, but are either stand-alone instruments or modified versions of the same. [Pg.584]

Several new oxalates have been developed for use ia analytical appHcations. Bis(2,6-difluorophenyl) oxalate (72) and bis(4-nitro-2-(3,6,9-trioxadecylcarbonyl)phenyl) oxalate (97) have been used ia flow iajection and high performance Hquid chromatography (hplc) as activators for chemiluminescence detectors. These oxalates are generally more stable and show better water solubiUty ia mixed aqueous solvents yet retain the higher efficiencies ( ) of the traditional oxalates employed for chemiluminescence. [Pg.268]

High performance Hquid chromatography (hplc) may be used to determine nitroparaffins by utilizing a standard uv detector at 254 nm. This method is particularly appHcable to small amounts of nitroparaffins present, eg, in nitro alcohols (qv), which caimot be analyzed easily by gas chromatography. Suitable methods for monitoring and deterrnination of airborne nitromethane, nitroethane, and 2-nitropropane have been pubUshed by the National Institute of Occupational Safety and Health (NIOSH) (97). Ordinary sorbant tubes containing charcoal are unsatisfactory, because the nitroparaffins decompose on it unless the tubes are held in dry ice and analyzed as soon after collection as possible. [Pg.103]

Mixtures can be identified with the help of computer software that subtracts the spectra of pure compounds from that of the sample. For complex mixtures, fractionation may be needed as part of the analysis. Commercial instmments are available that combine ftir, as a detector, with a separation technique such as gas chromatography (gc), high performance Hquid chromatography (hplc), or supercritical fluid chromatography (96,97). Instmments such as gc/ftir are often termed hyphenated instmments (98). Pyrolyzer (99) and thermogravimetric analysis (tga) instmmentation can also be combined with ftir for monitoring pyrolysis and oxidation processes (100) (see Analytical methods, hyphenated instruments). [Pg.315]

In addition, the appHcation of the mass spectrometer (ms) as a detector for gas—Hquid chromatography has made the positive identification of peaks possible. High performance Hquid chromatography (hplc), which involves various detectors, can be used to measure hydrophilic and hydrophobic organic compounds in water. [Pg.233]

Detectors. The function of the detector in HPLC is to monitor the mobile phase as it emerges from the column. The detection process in liquid chromatography has presented more problems than in gas chromatography there is, for example no equivalent to the universal flame ionisation detector of gas chromatography for use in liquid chromatography. Suitable detectors can be broadly divided into the following two classes ... [Pg.224]

Thin-layer chromatography (TLC) is used both for characterization of alcohol sulfates and alcohol ether sulfates and for their analysis in mixtures. This technique, combined with the use of scanning densitometers, is a quantitative analytical method. TLC is preferred to HPLC in this case as anionic surfactants do not contain strong chromophores and the refractive index detector is of low sensitivity and not suitable for gradient elution. A recent development in HPLC detector technology, the evaporative light-scattering detector, will probably overcome these sensitivity problems. [Pg.283]

A number of different types of HPLC detector have been discussed in the previous chapter. In comparison to these, a mass spectrometer is a relatively expensive detector and there need to be considerable advantages associated with its use to make the significant financial investment worthwhile. What are these advantages In order to answer this question, we must first consider what it is we are trying to achieve when using chromatography ... [Pg.49]

EC = electrical conductivity detector ECD = electron capture detector FPD = flame photometric detector GC = gas chromatography HPLC = high performance liquid chromatography NPD = nitrogen phosphorus detector TID = thermionic detector UV = ultraviolet spectroscopy... [Pg.180]

GC = gas chromatography ECD = electron capture detector EIA = enzyme-immunoassay GPC = gel permeation chromatography HPLC = high-performance liquid chromatography ITMS = ion trap mass spectrometer LSE = liquid solid extraction MS = mass spectrometry RSD = relative standard deviation SPE = solid phase extraction... [Pg.259]

The most common approaches to sulfonylurea determinations involve high-performance liquid chromatography (HPLC). The earliest reported methods utilized normal-phase liquid chromatography (LC) with photoconductivity detection this type of detector demonstrated undesirably long equilibration times and is no longer... [Pg.400]

Bispyribac in water samples can be directly quantifled by high-performance liquid chromatography (HPLC) using an ultravilot (UV) detector without methylation. [Pg.474]

High-performance liquid chromatography (HPLC) with a micellar mobile phase or with a selective pre-column or reaction detection system has also been used to determine alkylenebis(dithiocarbamaes). ° Zineb and mancozeb residues in feed were determined by ion-pair HPLC with ultraviolet (UV) detection at 272 nm. These compounds were converted to water-soluble sodium salts with ethylenediaminetetra-acetic acid (EDTA) and sodium hydroxide. The extracts were ion-pair methylated with tetrabuthylammonium hydrogensulfate (ion-pair reagent) in a chloroform-hexane solvent mixture at pH 6.5-8.S. The use of an electrochemical detector has also been reported. ... [Pg.1091]

Milbemectin consists of two active ingredients, M.A3 and M.A4. Milbemectin is extracted from plant materials and soils with methanol-water (7 3, v/v). After centrifugation, the extracts obtained are diluted to volume with the extraction solvent in a volumetric flask. Aliquots of the extracts are transferred on to a previously conditioned Cl8 solid-phase extraction (SPE) column. Milbemectin is eluted with methanol after washing the column with aqueous methanol. The eluate is evaporated to dryness and the residual milbemectin is converted to fluorescent anhydride derivatives after treatment with trifluoroacetic anhydride in 0.5 M triethylamine in benzene solution. The anhydride derivatives of M.A3 and M.A4 possess fluorescent sensitivity. The derivatized samples are dissolved in methanol and injected into a high-performance liquid chromatography (HPLC) system equipped with a fluorescence detector for quantitative determination. [Pg.1332]

Separations by column liquid chromatography (HPLC) and TIC occur by essentially the same physical processes. The two methods have often been considered as competitors when it would be more realistic to consider then as complementary, both having their own strengths and weaknesses. In HPLC each sample component must travel the complete length of the column and the total separation time is determined by the time required for the slowest moving component to reach the detector. While for TLC the total time for the separation is the time required for the solvent front to migrate a predetermined distance, and is independent of the migration distance of the sample components. Excessively retained components result in a considerable loss of time in HPLC while components accumulated at the head of the column are completely eluted, and if this is not possible, permanent alteration of the... [Pg.330]


See other pages where Chromatography HPLC detectors is mentioned: [Pg.53]    [Pg.754]    [Pg.783]    [Pg.1033]    [Pg.107]    [Pg.53]    [Pg.754]    [Pg.783]    [Pg.1033]    [Pg.107]    [Pg.201]    [Pg.108]    [Pg.167]    [Pg.360]    [Pg.480]    [Pg.316]    [Pg.109]    [Pg.349]    [Pg.865]    [Pg.493]    [Pg.127]    [Pg.226]    [Pg.14]    [Pg.375]    [Pg.415]    [Pg.4]    [Pg.27]    [Pg.101]    [Pg.1146]    [Pg.875]   