Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chemical activations analytical data

Another application involves the measurement of copper via the radioisotope Cu (12.6-hour half-life). Since Cu decays by electron capture to Ni ( Cu Ni), a necessary consequence is the emission of X rays from Ni at 7.5 keV. By using X-ray spectrometry following irradiation, sensitive Cu analysis can be accomplished. Because of the short range of the low-energy X rays, near-surface analytical data are obtained without chemical etching. A combination of neutron activation with X-ray spectrometry also can be applied to other elements, such as Zn and Ge. [Pg.678]

Other scientific disciplines required standards. WTien the American Type Culture Collection (ATCC) was founded in 1925, one of its chief roles was to be a source of standards for the rapidly developing public health laboratory activity in the USA. In this context we mean standard organisms, rather than standard materials or chemicals, but their use was analogous, they helped produce better analytical data. [Pg.2]

Hufford et al [57] used proton and 13C NMR spectrometric data to establish the novel sulfur-containing microbial metabolite of primaquine. Microbial metabolic studies of primaquine using Streptomyces roseochromogenus produced an A-acety-lated metabolite and a methylene-linked dimeric product, both of which have been previously reported, and a novel sulfur-containing microbial metabolite. The structure of the metabolite as an S-linked dimer was proposed on the basis of spectral and chemical data. The molecular formula C34H44N604S was established from field-desorption mass spectroscopy and analytical data. The 1H- and 13C NMR spectra data established that the novel metabolite was a symmetrical substituted dimer of primaquine A-acetate with a sulfur atom linking the two units at carbon 5. The metabolite is a mixture of stereoisomers, which can equilibrate in solution. This observation was confirmed by microbial synthesis of the metabolite from optically active primaquine. [Pg.183]

Cluster analysis Is used to determine the particle types that occur in an aerosol. These types are used to classify the particles in samples collected from various locations and sampling periods. The results of the sample classifications, together with meteorological data and bulk analytical data from methods such as instrunental neutron activation analysis (INAA). are used to study emission patterns and to screen samples for further study. The classification results are used in factor analysis to characterize spatial and temporal structure and to aid in source attribution. The classification results are also used in mass balance comparisons between ASEM and bulk chemical analyses. Such comparisons allow the combined use of the detailed characterizations of the individual-particle analyses and the trace-element capability of bulk analytical methods. [Pg.119]

We named the active constituent anandamide — based on the Sanskrit word ananda meaning delight, bliss, and on its chemical nature. A juxtaposition of the various analytical data led us to conclude that the structure of anandamide is that of arachidonoylethanolamide. This conclusion was confirmed by synthesis. [Pg.61]

During the Preparatory Commission and the first couple of years after EIF, the corresponding electronic version obtained from the Contributor was sent to the Finnish Institute for Verification of the Chemical Weapons Convention (VERIFIN (Finnish Institute for Verification of the Chemical Weapons Convention) actively participated in the building of the electronic version of the OCAD.) for incorporation into the electronic version of the OCAD. The original idea was to include all the different types of analytical data in a single relational database. The database developed by VERIFIN is a relational database (VERIFY) (for more information on the VERIFY database, contact VERIFIN (Finland)), which contains all the different... [Pg.135]

Chemical and physical analysis of the catalyst sections taken from the pilot plant reactor was undertaken. SEM and SIMS studies on the catalysts were also undertaken. The sulphur elemental analysis data are shown in Figure 2 and indicate that sulphur is only observed in the top position of the reactor. No other elemental analytical data (N, C etc correlated with the activity data. [Pg.353]

It appears that the largest source of error in these comparisons is the analytical data. The next largest source of error seems to be the adequacy of activity coefficients and stability constants used in the model and last is the reliability of the field Eh measurement. Close inspection of Figure 3 shows a slight bias of calculated Eh values towards more oxidizing potentials. Fe(III) complexes are quite strong and it is likely that some important complexes, possibly FeHSO " (5 4,5 5), should be included in the chemical model, but the thermodynamic data are not reliable enough to justify its use. [Pg.61]

Thermodynamic data, whether determined through calorimetry or solubility studies, are subject to refinement as more exact values for the components in the reaction scheme, or more complete description of the solution phases, become available. Many of the solubility studies on clays were done before digital-computer chemical equilibrium programs were available. One such program, SOLMNEQ, written by one of the authors ( ) solves the mass-action and mass-balance equations for over 200 species simultaneously. SOLMNEQ was employed in this investigation to convert the chemical analytical data into the activities of appropriate ions, ion pairs, and complexes. [Pg.390]

To derive free energy of formation data from solubility investigations, the solution phase must be in equilibrium with the solid phase and the activities of the ions must be known. The dissolution rate for clay minerals is extremely slow at 25 C consequently, most studies have allowed equilibration times of several years. Because of the requirement for a long equilibration time, a number of researchers have fitted kinetic expressions to the rate of dissolution and extrapolated to the equilibrium value. In all cases in this study, the chemical analytical data measured at what appeared to be equilibrium, rather than... [Pg.390]

The research for chemosensors began as a branch of analytical chemistry and is now an approved and independent field of activities at the interface between research and application. A chemosensor can be considered as a small unit for the acquisition of analytical data. It has been optimized for one distinct application includes a sensitive layer, whose physico-chemical properties are affected by the interaction with the substance to be detected. These effects are translated into electronic signals by microelectronic devices and can be processed by data acquisition systems [11]. In most cases, mass-sensitive or optical transducers are used, and some of them are listed in Table 10.1. [Pg.335]


See other pages where Chemical activations analytical data is mentioned: [Pg.319]    [Pg.5]    [Pg.5]    [Pg.28]    [Pg.3709]    [Pg.119]    [Pg.307]    [Pg.68]    [Pg.276]    [Pg.14]    [Pg.20]    [Pg.603]    [Pg.7]    [Pg.263]    [Pg.411]    [Pg.389]    [Pg.242]    [Pg.40]    [Pg.181]    [Pg.28]    [Pg.54]    [Pg.285]    [Pg.69]    [Pg.263]    [Pg.411]    [Pg.11]    [Pg.68]    [Pg.408]    [Pg.862]    [Pg.104]    [Pg.24]    [Pg.321]    [Pg.30]    [Pg.288]    [Pg.21]    [Pg.212]    [Pg.4]    [Pg.177]    [Pg.122]    [Pg.247]   


SEARCH



Activity Data

Analytical data

Chemical activity

Chemical data

Chemically active

© 2024 chempedia.info