Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Capillary electrophoresis Fourier transform

Jarman, J. L., Todebush, R. A., and De Haseth, J. A., Glass nebulizer interface for capillary electrophoresis—Fourier transform infrared spectrometry, J. Chromatogr. A, 976,19, 2002. [Pg.333]

H. A. HofstadlCT, J. H. Wahl, et al.. Capillary electrophoresis Fourier transform ion cyclotron mass spectrometry with sustained off-resonance irradiation for the characterization of proteins and peptides, J. Am. Soc. Mass Spectrom. 5, 894-899 (1994). [Pg.149]

Identification of stmctures of toxic chemicals in environmental samples requires to use modern analytical methods, such as gas chromatography (GC) with element selective detectors (NPD, FPD, AED), capillary electrophoresis (CE) for screening purposes, gas chromatography/mass-spectrometry (GC/MS), gas chromatography / Fourier transform infra red spectrometry (GC/FTIR), nucleai magnetic resonance (NMR), etc. [Pg.416]

Several additional instrumental techniques have also been developed for bacterial characterization. Capillary electrophoresis of bacteria, which requires little sample preparation,42 is possible because most bacteria act as colloidal particles in suspension and can be separated by their electrical charge. Capillary electrophoresis provides information that may be useful for identification. Flow cytometry also can be used to identify and separate individual cells in a mixture.11,42 Infrared spectroscopy has been used to characterize bacteria caught on transparent filters.113 Fourier-transform infrared (FTIR) spectroscopy, with linear discriminant analysis and artificial neural networks, has been adapted for identifying foodbome bacteria25,113 and pathogenic bacteria in the blood.5... [Pg.12]

DGE a AC AMS APCI API AP-MALDI APPI ASAP BIRD c CAD CE CF CF-FAB Cl CID cw CZE Da DAPCI DART DC DE DESI DIOS DTIMS EC ECD El ELDI EM ESI ETD eV f FAB FAIMS FD FI FT FTICR two-dimensional gel electrophoresis atto, 10 18 alternating current accelerator mass spectrometry atmospheric pressure chemical ionization atmospheric pressure ionization atmospheric pressure matrix-assisted laser desorption/ionization atmospheric pressure photoionization atmospheric-pressure solids analysis probe blackbody infrared radiative dissociation centi, 10-2 collision-activated dissociation capillary electrophoresis continuous flow continuous flow fast atom bombardment chemical ionization collision-induced dissociation continuous wave capillary zone electrophoresis dalton desorption atmospheric pressure chemical ionization direct analysis in real time direct current delayed extraction desorption electrospray ionization desorption/ionization on silicon drift tube ion mobility spectrometry electrochromatography electron capture dissociation electron ionization electrospray-assisted laser desorption/ionization electron multiplier electrospray ionization electron transfer dissociation electron volt femto, 1CT15 fast atom bombardment field asymmetric waveform ion mobility spectrometry field desorption field ionization Fourier transform Fourier transform ion cyclotron resonance... [Pg.11]

Capillary electrophoresis (CE) either coupled to MS or to laser-induced fluorescence (LIF) is less often used in metabolomics approaches. This method is faster than the others and needs a smaller sample size, thereby making it especially interesting for single cell analysis [215] The most sensitive mass spectrometers are the Orbitrap and Fourier transform ion cyclotron resonance (FT-ICR) MS [213]. These machines determine the mass-to-charge ratio of a metabolite so accurate that its empirical formula can be predicted, making them the techniques of choice for the identification of unknown peaks. [Pg.151]

Arakawa H, Neault JF, Tajmir-Riahi HA (2001) Silver complexes with DNA and RNA studied by Fourier transform infrared spectroscopy and capillary electrophoresis. Biophys J 81 1580-1587... [Pg.331]

Severs J.C., Hofstadler S.A., Zhao Z., Senh R.T., and Smith R.D. (1996), The interface of capillary electrophoresis with high performance Fourier transform ion cyclotron resonance mass spectrometry for biomolecule characterization, Electrophoresis 17(12) 1808-1817. [Pg.271]

Hofstadler, S. A., Severs, J. C., Smith, R. D., Swanek, F. D., and Ewing, A. G. (1996). Analysis of single cells with capillary electrophoresis electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. Rapid Commun. Mass Spectrom. 10, 919—922. [Pg.508]

Numerous analyses in the quality control of most kinds of samples occurring in the flavour industry are done by different chromatographic procedures, for example gas chromatography (GC), high-pressure liquid chromatography (fiPLC) and capillary electrophoresis (CE). Besides the different IR methods mentioned already, further spectroscopic techniques are used, for example nuclear magnetic resonance, ultraviolet spectroscopy, mass spectroscopy (MS) and atomic absorption spectroscopy. In addition, also in quality control modern coupled techniques like GC-MS, GC-Fourier transform IR spectroscopy, HPLC-MS and CE-MS are gaining more and more importance. [Pg.306]

The detector in capillary electrophoresis is the main component in nanoanalyses. Many detectors can be used for this purpose but the mass spectrometer is the best one due to its wide ranges and low concentration detection capabilities. In the last few years, time-of-flight-mass spectrometry (TOF-MS) instruments have come onto the market and are available in many sizes, but small instruments are preferred in NCE. Bruker (Billerica, MA) has provided a micro-TOF-MS-LC (2x2x4 feet) system for nanoanalyses. Bruker also introduced a Q-q-FTMS (Fourier transform mass spectrometer) for proteomics called the APEX-QE. It offers fast, dual quadrupoles, which provides the first stages followed by FTMS for the highest mass accuracy. It can be coupled to NCE and controlled by Bmker s ProteinScape work flow and warehousing... [Pg.82]

Kwok, Y.C., Manz, A., Shah convolution differentiation Fourier transform for rear analysis in microchip capillary electrophoresis../. Chromatogr. A 2001, 924(1-2), 177-186. [Pg.445]

Capillary Electrophoresis with Flame Photometric Detection Chemical Weapons Convention Extracted Ion Chromatogram Electron Impact Mass Spectrometry Electrospray Ionization Flow Injection Analysis Flame Photometric Detector Gas Chromatography/Fourier Transform Infrared Spectroscopy Gas Chromatography/Mass Spectrometry Gas chromatography International Union for Pure and... [Pg.126]

Capillary Electrophoresis Chemical Warfare Agents Chemical Weapons Convention Deuterated L-Alanine Triglycine Sulfate Dimethyl Ethylphosphonate Dimethyl Isopropylphosphonate Dimethyl Methylphosphonate Dimethyl Propylphosphonate Dimercaptotoluene Diffuse Reflectance Infrared Fourier Transform Functional Group Chromatograms Flame-Ionization Detector Fourier Transform Infrared Spectroscopy Gas Chromatography Gas Chromatography/Chemical Ionization/Mass Spectrometry Gas Chromatography/Chemical Ionization/Tandem Mass Spectrometry... [Pg.381]

Although not used in any of the overall methods found, Fourier transform-infrared spectroscopy for detection after GC can supplement MS to verify the presence of DNOC in samples (Budzinski et al. 1992 Gurka et al. 1991 Schneider et al. 1991). Alternative separation methods have also been shown to be applicable to nitrophenols, including DNOC, but have not yet become routine. These methods include supercritical fluid chromatography (Ong et al. 1992 Pospisil et al. 1992), capillary zone electrophoresis (Chao and Whang 1994), and micellar electrokinetic chromatography (Ong et al. 1991). [Pg.128]

Castoro, J.A., Chiu, R.W., Monnig, C.A. and Wilkins, C.L. (1992) Matrix-assisted laser desorp-tion/ionization of capillary electrophoresis effluents by fourier transform mass spectrometry. J. Am. Chem. Soc. 114, 7571-7572. [Pg.376]

Features. A series of boxed and highlighted Features are found throughout the text. These essays contain interesting applications of analytical chemistry to the modern world, derivation of equations, explanations of more difficult theoretical points, or historical notes. Examples include Breath Alcohol Analyzers (Chapter 7), Antioxidants (Chapter 20), Fourier Transform Spectroscopy (Chapter 25), LC/MS and LC/MS/MS (Chapter 32), and Capillary Electrophoresis in DNA Sequencing (Chapter 33). [Pg.1173]

The covalent interactions of small molecules with DNA have also been studied using electrospray. The use of liquid chromatography in conjunction with electrospray has been reviewed. The use of electrospray in conjunction with capillary electrophoresis has also been investigated. The stabilities of duplexes formed from 3, 5 - and 2, 5 - linked DNA have been compared by electrospray The binding of metal ions to oligonucleotides has also been studied using electrospray ionisation,Fourier transform ion cyclotron mass spectrometry. ... [Pg.228]


See other pages where Capillary electrophoresis Fourier transform is mentioned: [Pg.16]    [Pg.6]    [Pg.1]    [Pg.601]    [Pg.188]    [Pg.60]    [Pg.489]    [Pg.48]    [Pg.40]    [Pg.4]    [Pg.97]    [Pg.251]    [Pg.188]    [Pg.64]    [Pg.51]    [Pg.43]    [Pg.382]    [Pg.498]    [Pg.598]    [Pg.272]    [Pg.265]    [Pg.200]    [Pg.1104]    [Pg.205]   
See also in sourсe #XX -- [ Pg.400 , Pg.401 , Pg.402 , Pg.403 , Pg.404 ]




SEARCH



Capillary electrophoresis transforms

© 2024 chempedia.info