Fourier Transform Infrared Detectors

The Fourier transform infrared (FTIR) detector is a nondestructive and concentration-sensitive detector, which is universal. The detection limit is about 150 pg, depending on the compound, and the linearity is 10.  [Pg.36]

As mentioned in Section 2.1, GC separations can be carried out on both adsorbents (GSC) and liquid stationary phases (GLC). [Pg.36]

GSC is mainly used for separation of gases and low molecular mass compounds. [Pg.36]

Packed columns or porous layer open tubular columns can be used. The particles constitute the stationary phase the adsorbent. Different adsorbents are used active carbon, molecular sieves, and porous polymers. [Pg.36]

Active carbon is available in several qualities and has a pore structure similar to a molecular sieve. In addition to adsorption, separation according to size also contributes to the separation of gases. The gases that can be separated on active carbon materials are CO, CH4, CO2, and N2. For detection of these gases, the thermal conductivity detector must be used. In addition, small alcohols, aldehydes, and water can be chromatographed on active carbon materials. [Pg.36]


Hadj-Mahammed, M., Badjah-Hadj-Ahmed, Y., and Meklati, B.Y., Behavior of pol5nnethoxy-lated and polyhydroxylated flavones by carbon dioxide supercritical fluid chromatography with flame ionization and Fourier transform infrared detectors, Phytochem. Anal, 4, 275, 1993. [Pg.137]

Mass Spectrometer and Fourier Transform Infrared Detectors... [Pg.379]

Several detectors are used for VOCs analysis by GC flame ionization detector (FID), photo ionization detector (PID), electron capture detector (BCD), electrolytic conductivity detector (ELCD), mass spectrometer detector (MSD or MS), and Fourier-transform infrared detector (FTIRD). For the in-depth reviews of the detectors, readers are directed to Refs. [52-54]. Examples of ICP-MS or microwave-induced plasma atomic emission spectrometry (atomic emission detector, AED) have been reported as detection technique after chromatographic separation [55,56]. Current trends and developments in GC analysis of VOCs have been recently reviewed by the group of Dewulf [16,57]. Mass spectrometer detectors allow low detection limits in single/selected ion monitoring (SIM) and a qualitative confirmation by full scan mode or by means of other ion selected as qualifier. [Pg.608]

Two common detectors, which also are independent instruments, are Fourier transform infrared spectrophotometers (FT-IR) and mass spectrometers (MS). In GC-FT-IR, effluent from the column flows through an optical cell constructed... [Pg.570]

For radiofrequency and microwave radiation there are detectors which can respond sufficiently quickly to the low frequencies (<100 GHz) involved and record the time domain specttum directly. For infrared, visible and ultraviolet radiation the frequencies involved are so high (>600 GHz) that this is no longer possible. Instead, an interferometer is used and the specttum is recorded in the length domain rather than the frequency domain. Because the technique has been used mostly in the far-, mid- and near-infrared regions of the spectmm the instmment used is usually called a Fourier transform infrared (FTIR) spectrometer although it can be modified to operate in the visible and ultraviolet regions. [Pg.55]

Chemical Gas Detection. Spectral identification of gases in industrial processing and atmospheric contamination is becoming an important tool for process control and monitoring of air quaUty. The present optical method uses the ftir (Fourier transform infrared) interference spectrometer having high resolution (<1 cm ) capabiUty and excellent sensitivity (few ppb) with the use of cooled MCT (mercury—cadmium—teUuride) (2) detectors. [Pg.295]

Spectroscopy. Infrared spectroscopy (48) permits stmctural definition, eg, it resolves the 2,2 - from the 2,4 -methylene units in novolak resins. However, the broad bands and severely overlapping peaks present problems. For uncured resins, nmr rather than ir spectroscopy has become the technique of choice for microstmctural information. However, Fourier transform infrared (ftir) gives useful information on curing phenoHcs (49). Nevertheless, ir spectroscopy continues to be used as one of the detectors in the analysis of phenoHcs by gpc. [Pg.299]

Such effects principally cannot be observed in multi band detectors such as a UV diode array detector or a Fourier transform infrared (FTIR) detector because all wavelengths are measured under the same geometry. For all other types of detectors, in principle, it is not possible to totally remove these effects of the laminar flow. Experiments and theoretical calculations show (8) that these disturbances can only be diminished by lowering the concentration gradient per volume unit in the effluent, which means that larger column diameters are essential for multiple detection or that narrow-bore columns are unsuitable for detector combinations. Disregarding these limitations can lead to serious misinterpretations of GPC results of multiple detector measurements. Such effects are a justification for thick columns of 8-10 mm diameter. [Pg.441]

The growth and decay of all other species (including O3) were monitored by Fourier transform infrared (FT-IR) spectroscopy at a total pathlength of 460 meters and a spectral resolution of 1 cm". At this pathlength, the intense absorptions of H2O and CO limit the usable IR spectral windows to the approximate regions 750-1300, 2000-2300, and 2400-3000 cm". Each spectrum (700-3000 cm" ) was adequately covered by the response of the Cu Ge detector. Approximately 40 seconds were required to collect the 32 interferograms co-added for each spectrum. [Pg.118]

Detection in SFC can be achieved in the condensed phase using optical detectors similar to those used in liquid chromatography or in the gas phase using detectors similar to those used in gas chromatography. Spectroscopic detectors, such as mass spectrometry and Fourier transform infrared spectroscopy, are relatively easily interfaced to SFC compared to the problems observed with liquid mobile phases (see Chapter 9). The range of available detectors for SFC is considered one of its strengths. [Pg.837]

Miniaturized chemical analysis systems have been developed for most macroscopic counterparts (Dittrich et al. 2006). The availability of optical fibers, light sources, and detectors in the visible UV and near-infrared (NIR) wavelengths makes it possible to integrate spectroscopic measurements in microreactors (Lobbecke et al. 2005). Fourier transform infrared spectroscopy (FTIR) is an efficient, broadly applicable... [Pg.68]

Figure 4.5 Schematic diagram of a Fourier transform infrared (FTIR) spectrometer. Infrared radiation enters from the left and strikes a beam-splitting mirror (BS) angled such that half of the beam is directed towards a fixed mirror (Mi) and half towards a moveable mirror (M2). On reflection the beam is recombined and directed through the sample towards the detector. M2 is moved in and out by fractions of a wavelength creating a phase difference between the two beam paths. This type of device is called a Michelson interferometer. Figure 4.5 Schematic diagram of a Fourier transform infrared (FTIR) spectrometer. Infrared radiation enters from the left and strikes a beam-splitting mirror (BS) angled such that half of the beam is directed towards a fixed mirror (Mi) and half towards a moveable mirror (M2). On reflection the beam is recombined and directed through the sample towards the detector. M2 is moved in and out by fractions of a wavelength creating a phase difference between the two beam paths. This type of device is called a Michelson interferometer.
A Fourier transform infrared spectroscopy spectrometer consists of an infrared source, an interference modulator (usually a scanning Michelson interferometer), a sample chamber and an infrared detector. Interference signals measured at the detector are usually amplified and then digitized. A digital computer initially records and then processes the interferogram and also allows the spectral data that results to be manipulated. Permanent records of spectral data are created using a plotter or other peripheral device. [Pg.31]

Olsen, E. Serially interfaced gas chromatography/Fourier Transform infrared spectrometer/ion trap detector. Finnigan MAT IDT 35. [Pg.117]

We discussed the fundamentals of mass spectrometry in Chapter 10 and infrared spectrometry in Chapter 8. The quadrupole mass spectrometer and the Fourier transform infrared spectrometer have been adapted to and used with GC equipment as detectors with great success. Gas chromatography-mass spectrometry (GC-MS) and gas chromatography-infrared spectrometry (GC-IR) are very powerful tools for qualitative analysis in GC because not only do they give retention time information, but, due to their inherent speed, they are also able to measure and record the mass spectrum or infrared (IR) spectrum of the individual sample components as they elute from the GC column. It is like taking a photograph of each component as it elutes. See Figure 12.14. Coupled with the computer banks of mass and IR spectra, a component s identity is an easy chore for such a detector. It seems the only real... [Pg.351]

Other methods for the determination of aromatics in naphtha include a method (ASTM D5580) using a flame ionization detector and methods that use combinations of gas chromatography and Fourier transform infrared spectroscopy (GC-FTIR) (ASTM D5986) and gas chromatography and mass spectrometry (GC-MS) (ASTM D5769). [Pg.263]

The most recent advance in VCD instrumentation has been its adaptation to Fourier transform infrared (FTIR) measurement (23-25). The details of this technique involve a new method of FTIR measurement termed double-modulation FTIR spectroscopy. Thus spectra of very high quality and resolution have been obtained using a standard VCD modulator and detector, a glower source, and a commercially available FTIR spectrometer system. In fact an entire FTIR-VCD spectrometer can be assembled from a few commercially available components. It is found that the major advantages of resolution, throughput, and... [Pg.119]


See other pages where Fourier Transform Infrared Detectors is mentioned: [Pg.281]    [Pg.36]    [Pg.164]    [Pg.281]    [Pg.36]    [Pg.164]    [Pg.195]    [Pg.106]    [Pg.864]    [Pg.85]    [Pg.313]    [Pg.453]    [Pg.187]    [Pg.98]    [Pg.24]    [Pg.156]    [Pg.323]    [Pg.908]    [Pg.149]    [Pg.212]    [Pg.80]    [Pg.35]    [Pg.151]    [Pg.216]    [Pg.368]    [Pg.269]    [Pg.337]    [Pg.76]   
See also in sourсe #XX -- [ Pg.224 ]

See also in sourсe #XX -- [ Pg.153 ]

See also in sourсe #XX -- [ Pg.36 ]

See also in sourсe #XX -- [ Pg.37 , Pg.69 , Pg.70 , Pg.71 , Pg.271 ]