Capillary columns pressure

Ivanov, A. R., Horvath, C. and Karger, B. L. High-efficiency peptide analysis on monolithic multi-mode capillary columns Pressure-assisted capillary electrochromatography/capillary electrophoresis coupled to UV and electrospray ionization-mass spectrometry. Electrophoresis, 24,3663, 2003. [Pg.287]

An injection technique in capillary electrophoresis in which pressure is used to inject sample into the capillary column. [Pg.602]

As described above, the mobile phase carrying mixture components along a gas chromatographic column is a gas, usually nitrogen or helium. This gas flows at or near atmospheric pressure at a rate generally about 0,5 to 3.0 ml/min and evenmally flows out of the end of the capillary column into the ion source of the mass spectrometer. The ion sources in GC/MS systems normally operate at about 10 mbar for electron ionization to about 10 mbar for chemical ionization. This large pressure... [Pg.254]

Figure 12.18 LC-SFC analysis of mono- and di-laurates of poly (ethylene glycol) ( = 10) in a surfactant sample (a) normal phase HPLC trace (b) chromatogram obtained without prior fractionation (c) chromatogram of fraction 1 (FI) (d) chromatogram of fraction 2 (F2). LC conditions column (20 cm X 0.25 cm i.d.) packed with Shimpak diol mobile phase, w-hexane/methylene chloride/ethanol (75/25/1) flow rate, 4 p.L/min UV detection at 220 nm. SFC conditions fused-silica capillary column (15 m X 0.1 mm i.d.) with OV-17 (0.25 p.m film thickness) Pressure-programmed at a rate of 10 atm/min from 80 atm to 150 atm, and then at arate of 5 atm/min FID detection. Reprinted with permission from Ref. (23). Figure 12.18 LC-SFC analysis of mono- and di-laurates of poly (ethylene glycol) ( = 10) in a surfactant sample (a) normal phase HPLC trace (b) chromatogram obtained without prior fractionation (c) chromatogram of fraction 1 (FI) (d) chromatogram of fraction 2 (F2). LC conditions column (20 cm X 0.25 cm i.d.) packed with Shimpak diol mobile phase, w-hexane/methylene chloride/ethanol (75/25/1) flow rate, 4 p.L/min UV detection at 220 nm. SFC conditions fused-silica capillary column (15 m X 0.1 mm i.d.) with OV-17 (0.25 p.m film thickness) Pressure-programmed at a rate of 10 atm/min from 80 atm to 150 atm, and then at arate of 5 atm/min FID detection. Reprinted with permission from Ref. (23).
A more sensitive separation scheme is presented in Figure 14.4. This valveless switching System was originally developed by Deans (10, 11) and utilizes pressures to direct the flows through the different columns. Two capillary columns are used, of which the first separates the hydrocarbons from each other and from the sulfur gases. [Pg.382]

Figure 14.4 Schematic diagram of the cliromatographic system used for the analysis of very low concentrations of sulfur compounds in ethene and propene CP, pressure regulator CF, flow regulator SL, sanrple loop R, restriction to replace column 2 VI, injection valve V2, tliree-way valve to direct the effluent of column 1 to either column 2 or the restriction column 1, non-polar- capillary column column 2, tliick-film capillary column SCD, sulfur chemiluminescence detector FID, flanre-ionization detector. Figure 14.4 Schematic diagram of the cliromatographic system used for the analysis of very low concentrations of sulfur compounds in ethene and propene CP, pressure regulator CF, flow regulator SL, sanrple loop R, restriction to replace column 2 VI, injection valve V2, tliree-way valve to direct the effluent of column 1 to either column 2 or the restriction column 1, non-polar- capillary column column 2, tliick-film capillary column SCD, sulfur chemiluminescence detector FID, flanre-ionization detector.
Figure 14.10 Schematic diagram of the aromatics analyser system BP, back-pressure regulator CF, flow controller CP, pressure controller Inj, splitless injector with septum purge V, tliree-way valve column I, polar capillary column column 2, non-polar capillary column R, restrictor FID I, and FID2, flame-ionization detectors. Figure 14.10 Schematic diagram of the aromatics analyser system BP, back-pressure regulator CF, flow controller CP, pressure controller Inj, splitless injector with septum purge V, tliree-way valve column I, polar capillary column column 2, non-polar capillary column R, restrictor FID I, and FID2, flame-ionization detectors.
The cracking of diphenylmethane (DPM) was carried out in a continuous-flow tubular reactor. The liquid feed contained 29.5 wt.% of DPM (Fluka, >99%), 70% of n-dodecane (Aldrich, >99% solvent) and 0.5% of benzothiophene (Aldrich, 95% source of H2S, to keep the catalyst sulfided during the reaction). The temperature was 673 K and the total pressure 50 bar. The liquid feed flow rate was 16.5 ml.h and the H2 flow rate 24 l.h (STP). The catalytic bed consisted of 1.0 g of catalyst diluted with enough carborundum (Prolabo, 0.34 mm) to reach a final volume of 4 cm. The effluent of the reactor was condensed at high pressure. Liquid samples were taken at regular intervals and analyzed by gas chromatography, using an Intersmat IGC 120 FL, equipped with a flame ionization detector and a capillary column (Alltech CP-Sil-SCB). [Pg.100]

Catalytic reactions. The reaction was carried out at 543-643 K by using a flow reaction system with a mixtiue of EA, NH3, and Nz in the ratio of 1/50/25 at atmospheric pressure. The flow rate of the mixture gas was 76 cm min. Prior to the reaction, the catalyst was calcined at 773 K under O2 flow for 2 h. The reaction products were analyzed by an on-line gas chromatograph (FID) which was equipped with a 30-m capillary column (TCI701). [Pg.268]

Early work relied on the use of packed columns, but all modern GC analyses are accomplished using capillary columns with their higher theoretical plate counts and resolution and improved sensitivity. Although a variety of analytical columns have been employed for the GC of triazine compounds, the columns most often used are fused-silica capillary columns coated with 5% phenyl-95% methylpolysiloxane. These nonpolar columns in conjunction with the appropriate temperature and pressure programming and pressure pulse spiking techniques provide excellent separation and sensitivity for the triazine compounds. Typically, columns of 30 m x 0.25-mm i.d. and 0.25-qm film thickness are used of which numerous versions are commercially available (e.g., DB-5, HP-5, SP-5, CP-Sil 8 CB, etc.). Of course, the column selected must be considered in conjunction with the overall design and goals of the particular study. [Pg.440]

Fast chromatography involves the use of narrow-bore columns (typically 0.1-mm i.d.) that will require higher inlet pressures compared with the conventional wide-bore capillary columns. These columns require detectors and computing systems capable of fast data acquisition. The main disadvantage is a much-reduced sample loading capacity. Advances in GC column technology, along with many of the GC-related techniques discussed below, were recently reviewed by Eiceman et... [Pg.737]

Figure 1.17 Separation of large ring polycyclic aroaatic hydrocarbons extracted from carbon black on a 1.8 x 0.2 n I.D. fused silica capillary column packed with 3 micrometer spherical octadecylsllanized silica gel eluted with a stepwise solvent gradient at a flow rate of 1.1 mlcroliters/min with an inlet pressure of about 360 atmospheres. Under isocratic conditions this column yielded ca. 225,000 theoretical plates. (Reproduced with permission from ref. 238. Copyright Friedr. Vieweg t Sohn). Figure 1.17 Separation of large ring polycyclic aroaatic hydrocarbons extracted from carbon black on a 1.8 x 0.2 n I.D. fused silica capillary column packed with 3 micrometer spherical octadecylsllanized silica gel eluted with a stepwise solvent gradient at a flow rate of 1.1 mlcroliters/min with an inlet pressure of about 360 atmospheres. Under isocratic conditions this column yielded ca. 225,000 theoretical plates. (Reproduced with permission from ref. 238. Copyright Friedr. Vieweg t Sohn).
The problems associated with coupling packed columns to a mass spectrometer are s re severe than those encountered with capillary columns. Conventional pacdced columns are operated at much higher flow rates, 20 to 60 al/ain, and although this diminishes the influence of dead volumes in the interface on sample resolution, it poses a problem due to the pressure and volume flow rate restrictions of the mass spectrometer. The interface must provide a pressure drop between column and mass spectrometer source on the order of 10 to 10, it must reduce the volumetric flow of gas into the mass spectrometer without diminishing the mass flow of sample by the same amount, and it must retain the integrity of the sample eluting from the column in terms of the separation obtained and its chemical constitution [3,25,26]. To meet the above requirements the interface must function as a molecular separator. [Pg.487]

Chromatography by ion exchange on a sulfonated poly(styrene-co-divinyl benzene) phase has been proposed as a replacement for titrimetry.57 Eluted by a dilute solution of a neutral salt such as sodium ethanesulfonate, the conductance of the protons can be measured in the absence of a suppressor from sub-millimolar to molar concentration. The response factors of mono-, di-, and trichloroacetic acid and of o-phthalic acid were large and essentially equivalent to ethanesulfonic acid, while the response factor of acetic acid was far smaller. A syringe pump has generated pressures as high as 72,000 psi (5000 bar) in a capillary column packed with 1 p particles, generating a fraction capacity of 300 peaks in 30 minutes.58... [Pg.64]


See other pages where Capillary columns pressure is mentioned: [Pg.268]    [Pg.268]    [Pg.9]    [Pg.563]    [Pg.565]    [Pg.773]    [Pg.250]    [Pg.226]    [Pg.150]    [Pg.218]    [Pg.272]    [Pg.239]    [Pg.239]    [Pg.258]    [Pg.562]    [Pg.498]    [Pg.592]    [Pg.316]    [Pg.432]    [Pg.530]    [Pg.481]    [Pg.40]    [Pg.79]    [Pg.80]    [Pg.147]    [Pg.421]    [Pg.544]    [Pg.563]    [Pg.640]    [Pg.645]    [Pg.690]    [Pg.693]    [Pg.696]    [Pg.910]    [Pg.912]    [Pg.396]    [Pg.184]   
See also in sourсe #XX -- [ Pg.116 , Pg.252 , Pg.356 ]