Bench top

Ether. The most satisfactory method for the removal of (diethyl) ether is either on a steam bath fed from an external steam supply or by means of an electrically-heated, constant-level water bath (Fig. 77, 5, 1). If neither of these is available, a water bath containing hot water may be used. The hot water should be brought from another part of the laboratory under no circumstances should there be a free flame under the water bath. It caimot be too strongly emphasised that no flame whatsoever may be present in the vicinity of the distillation apparatus a flame 10 feet away may ignite diethyl ether if a continuous bench top lies between the flame and the still and a gentle draught happens to be blowing in the direction of the flame. [Pg.90]

Chemical systems spontaneously react in a fashion that lowers their overall free energy. At a constant temperature and pressure, typical of many bench-top chemical reactions, the free energy of a chemical reaction is given by the Gibb s free energy function... [Pg.137]

Acetone can be handled safely if common sense precautions are taken. It should be used in a weU-ventilated area, and because of its low flash point, ignition sources should be absent. Flame will travel from an ignition source along vapor flows on floors or bench tops to the point of use. Sinks should be rinsed with water while acetone is being used to clean glassware, to prevent the accumulation of vapors. If prolonged or repeated skin contact with acetone could occur, impermeable protective equipment such as gloves and aprons should be worn. [Pg.98]

Corning 0330 P-spodumene soHd solution mtile HO2 mechanical, chemical, thermal stabiHty exterior, interior cladding, laboratory bench tops... [Pg.289]

Bench-top or microunits will continue to be the predominant type of pdot plant constmcted due to their lower constmction and operating costs. Demonstration and prototype units will become even rarer for the opposite reasons. [Pg.43]

In the laboratory, sodium is best handled in a glove box filled with nitrogen or another inert gas, or in a water-free hood. When sodium is handled on the bench top, water and aqueous solutions must be excluded from the area. Tools for cutting or handling sodium must be clean and dry. Contact of sodium with air should be kept to a minimum because moisture in the air reacts rapidly with sodium. A metal catch pan under the equipment is essential to... [Pg.168]

In addition to electrical uses, epoxy casting resins are utilized in the manufacture of tools, ie, contact and match molds, stretch blocks, vacuum-forrning tools, and foundry patterns, as weU as bench tops and kitchen sinks. Systems consist of a gel-coat formulation designed to form a thin coating over the pattern which provides a perfect reproduction of the pattern detail. This is backed by a heavily filled epoxy system which also incorporates fiber reinforcements to give the tool its strength. For moderate temperature service, a Hquid bisphenol A epoxy resin with an aHphatic amine is used. For higher temperature service, a modified system based on an epoxy phenol novolak and an aromatic diamine hardener may be used. [Pg.371]

A bench-top power supply that can simulate the input power source. This will be a large dc power supply with voltage and current ratings in excess of what is needed. For off-line power supplies, use a variac with a current rating in excess of what is needed. [Pg.10]

An apparatus resembling that pictured by Schlatter is assembled in a good hood. Two 5-1. three-necked flasks are mounted side by side about 10 cm. apart and about 10 cm. above the bench top or stand base. These arc referred to as the left and right flasks. Kach flask is provided with a dry ice condenser in the outermost neck, and each condenser is [imlected from the... [Pg.1]

Fig. 2 Synthos 3000 bench-top multimode microwave apparatus of Anton Paar... Fig. 2 Synthos 3000 bench-top multimode microwave apparatus of Anton Paar...
We have reported a simple, green, bench top, economical and environmentally benign room temperature synthesis of MSe (M=Cd or Zn) nanoparticles using starch, PVA and PVP as passivating agents. The whole process is a redox reaction with selenium acting as the oxidant and MSe as the reduction product. An entire "green" chemistry was explored in this synthetic procedure and it is reproducible. The optical spectroscopy showed that all the particles are blue shifted from the bulk band gap clearly due to quantum confinement. Starch capped CdSe nanoparticles showed the presence of monodispersed spherical... [Pg.179]

In another facility, bench tops in the main room were covered with epoxy-treated monolithic material to resist the hard wear anticipated. The side room, where instrument work was to be carried out, was equipped with tops of plastic laminate. This resulted in substantial savings. Somehow it was difficult to convince the engineering firm in charge of building the laboratory that monolithic material, which they had recommended throughout, was not necessary everywhere. [Pg.81]

A bench top polysulfone hollow fiber membrane (0.0325m ) with molecular weight cutoff (MWCO) of 30K (A/G Technology Corp., Needham MA) was used (24). UF was run in a total recycle mode at a rate of 1.2 L/min (flow speed of 0.73 m/sec), cross membrane pressure of 25 PSIG and 10 + 1°C. PE permeability is expressed as the fraction of PEU/mL in the permeate to PEU/mL in the retentate. Data presented are representative of at least duplicate replications. [Pg.476]

Heller and Tabibian (13) noted that errors, due to laterally scattered light and the corona effect, as large as to cause a 30 reduction in measured turbidity, may result if instruments which are perfectly suitable for ordinary absorption measurements are used for turbidity measurements without proper modifications. To evaluate the performance of our turbidity detector, particle suspensions of various concentrations of several polystyrene latex standards were prepared. Their extinction coefficients were measured using both a bench-top UV spectrophotometer (Beckman, Model 25) and the online detector (Pharmacia). [Pg.52]

Universal and selective detectors, linked to GC or LC systems, have remained the predominant choice of analysts for the past two decades for the determination of pesticide residues in food. Although the introduction of bench-top mass spectrometers has enabled analysts to produce more unequivocal residue data for most pesticides, in many laboratories the use of selective detection methods, such as flame photometric detection (FPD), electron capture detection (BCD) and alkali flame ionization detection (AFID) or nitrogen-phosphorus detection (NPD), continues. Many of the new technologies associated with the on-going development of instrumental methods are discussed. However, the main objective of this section is to describe modern techniques that have been demonstrated to be of use to the pesticide residue analyst. [Pg.737]

Specificity is unsurpassed. Traditionally, MS was performed on very large and expensive high-resolution sector instruments operated by experienced specialists. The introduction of low-resolution (1 amu), low-cost, bench-top mass spectrometers in the early 1980s provided analysts with a robust analytical tool with a more universal range of application. Two types of bench-top mass spectrometers have predominated the quadrupole or mass-selective detector (MSD) and the ion-trap detector (ITD). These instruments do not have to be operated by specialists and can be utilized routinely by residue analysts after limited training. The MSD is normally operated in the SIM mode to increase detection sensitivity, whereas the ITD is more suited to operate in the full-scan mode, as little or no increase in sensitivity is gained by using SIM. Both MSDs and ITDs are widely used in many laboratories for pesticide residue analyses, and the preferred choice of instrument can only be made after assessment of the performance for a particular application. [Pg.740]

Fieiure 9-1 Schematic view of (A) the bench-top quadrupole mass spectrometer (Hewlett-Packard) and (B) the ion trap detector (Finnigan MAT). [Pg.485]

The relatively low entry level instrumentation cost and the relatively simple experimental methods associated with GARField - both comparable to a standard bench-top relaxation analysis spectrometer as commonly used by the food industry, for example, for water/fat ratio determinations - offer potential advantages to the industrial based user. Indeed, the overwhelming majority of the applications development work described here has been carried out in collaboration with major multi-national industrial corporations such as ICI Paints, Unilever and Uniqema, with industry sponsored research laboratories and associations such as Traetek, and with a range of small-medium sized enterprises. [Pg.90]

GARField has found a niche application area in the characterization of drying and film forming from aqueous dispersions and in skin-care. As a bench-top perma-... [Pg.105]


See other pages where Bench top is mentioned: [Pg.450]    [Pg.95]    [Pg.292]    [Pg.39]    [Pg.40]    [Pg.40]    [Pg.406]    [Pg.153]    [Pg.158]    [Pg.891]    [Pg.290]    [Pg.150]    [Pg.283]    [Pg.431]    [Pg.1]    [Pg.147]    [Pg.144]    [Pg.444]    [Pg.727]    [Pg.741]    [Pg.827]    [Pg.1148]    [Pg.509]    [Pg.992]    [Pg.49]    [Pg.90]    [Pg.91]    [Pg.267]   
See also in sourсe #XX -- [ Pg.49 , Pg.90 , Pg.267 ]