Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Bellows

The implementation of high-pressure reaction cells in conjunction with UFIV surface science techniques allowed the first tme in situ postmortem studies of a heterogeneous catalytic reaction. These cells penult exposure of a sample to ambient pressures without any significant contamination of the UFIV enviromnent. The first such cell was internal to the main vacuum chamber and consisted of a metal bellows attached to a reactor cup [34]- The cup could be translated using a hydraulic piston to envelop the sample, sealing it from... [Pg.938]

A mechanical device embodying a bellows-sealed needle valve with a lever reduction movement for fine control is shown in Fig. II, 23, 5. The needle is of stainless steel. This fine control valve assembly is useful for pressures ranging from 20 to 100 mm. of mercury when used in conjunction with a good water pump. [Pg.115]

Oleum is marketed in all strengths up to ca. 70 per cent. SO3. From 0 to 40 per cent, free SO3, it is a liquid from 40 to 60 per cent, free SO3, it is a solid from 60 to 70 per cent, free SO3, it is liquid above 70 per cent, free SO3, it is a solid. The acid must be kept in ground glass stoppered, thick-walled bottles. If it is required to melt the acid, the stopper is removed, a watch glass placed on the mouth of the bottle, and the bottle placed in a layer of sand in an air bath which is warmed with a small flame. The bottle is fitted with a wash bottle attachment, and any desired quantity of acid is forced out by gentle air pressure from a hand or foot bellows (the mouth must not be used) this procedure is far more satisfactory than that of pouring the liquid acid from the bottle. [Pg.188]

Belleville washers Bell furnace Bellodgia Bellows... [Pg.95]

As a vessel is loaded, it moves downward because of deflection of the load cells and support stmcture. Pipes rigidly attached to a vessel restrict its free movement and assume some portion of the load that cannot be measured by the load cells. This is very detrimental to scale accuracy. Deflection of the load cell is unavoidable deflection of the vessel support stmcture should be minimized. Anything which increases vessel deflection, eg, mbber pads used for shock protection, must be avoided. The total number of pipes should be minimized and be of the smallest diameter, thinnest wall possible. Pipe mns to weigh vessels must be horizontal and the first pipe support should be as far as possible from the vessel. Alternatively, a section of mbber hose or flexible bellows should be used to make the final connection to the vessel. The scale should be caUbrated using weights, not by means of an electrical simulation method, which cannot account for the effects of the piping or test the correct functioning of the scale. [Pg.337]

Bellows or Dia.phra.gm Meters. Bellows meters use flexible diaphragms as the metering chambers. A series of valves and linkages control the filling and emptying of the chambers. Movement of the flexible walls is regulated for a constant displacement per stroke. Meters of this type are widely used in the gas industry as residential meters (see Gas, natural). [Pg.58]

Hydraulic fluid resistance makes fluorosihcones the preferred military aircraft choice for the manufacture of the flexible bellows (12) between the hydraulic fluid reservoir and the suction pump on Northrop Corp. s T-38 trainers and T-5 fighters. Its use allows for fluid continuity during normal and inverted flight attitudes. [Pg.401]

The Stuckofen or old high bloomery appeared in Germany in ca 1300 AD. This type of furnace was 3—5 m high and enclosed a tapered vertical shaft that was 1—1.2 m in diameter. Small openings near the bottom were provided for no22les (tuyeres, pronounced tweers) that permitted air, suppHed by bellows, to be blown into the furnace. Modem blast furnaces have essentially the same fundamental design. [Pg.412]

G. Bellows, ISlon-Traditional Machining Guide 26 Nemomers for Production, Metcut Research Associates Inc., Cincinnati, Ohio, 1976, pp. 28—29. [Pg.311]

The movement-absorbing devices used in semirigid and nonrigid piping systems are usually called expansion joints. Based on the method by which the pressure seal is effected, joints are either of the packed type or the packless or bellows type. Selection depends not only on the required movement but also on the severity of service in terms of pressure and temperature, tolerabiUty of leakage, and the number of service cycles. [Pg.65]

Dual-beUows assembhes, ie, universal-type expansion joints, are particularly vulnerable to squirm, and can experience elastic squirm at one-fourth the pressure of an individual bellows. When large amounts of offset are encountered, as is often the design basis, a pinwheel effect occurs because of unbalanced pressure forces. This effect tends to rotate the center-spool pipe which may lead to bellows mpture. Eor this reason the center spool should always be stabilized by hinges or tie-rod lugs to prevent such rotation. [Pg.66]

Bellows can vibrate, both from internal fluid flow and externally imposed mechanical vibrations. Internal flow liner sleeves prevent flow-induced resonance, which produces bellows fatigue failure in minutes at high flow velocities. Mechanically induced resonant vibration is avoided by a bellows with a natural frequency far away from the forcing frequency, if known. Multiple-ply bellows are less susceptible to vibration failure because of the damping effect of interply friction. [Pg.66]

The bellows is formed from a length of thin-walled tubing by extmsion in a die. The metals used in the constmction of the bellows must be ductile enough for reasonably easy fabrication and have a high resistance to fatigue failure. Materials commonly used are brass, bronze, beryllium copper, alloys of nickel and copper, steel, and Monel (5). [Pg.22]

Meters. Diaphragms, diaphragm capsules, and bellows elements ate used extensively in meter bodies designed to measure differential pressure. These units can be used to measure the differences in pressure between two water lines, two steam headers, two stills, etc, from 25 Pa (0.1 in. H2O) to... [Pg.22]

High pressure bellows Restriction ring Center-stem assembly Zero-setting screw High pressure overload seal Range-spring assembly Torque-tube assembly... [Pg.23]

Pressure. Most pressure measurements are based on the concept of translating the process pressure into a physical movement of a diaphragm, bellows, or a Bourdon element. For electronic transmission, these basic elements are coupled with an electronic device for transforming a physical movement associated with the element into an electronic signal proportional to the process pressure, eg, a strain gauge or a linear differential variable transformer (LDVT). [Pg.65]

Vapor Pressure. The Shiley Infusaid implantable infusion pump utilizes energy stored in a two-phase fluorinated hydrocarbon fluid. The pump consists of a refillable chamber that holds the dmg and a chamber that holds the fluid. The equiUbrium vapor pressure of the fluid, a constant 60 kPa (450 mm Hg), compresses the bellows, pumping the dmg through a bacterial filter, a capillary flow restrictor, and an infusion cannula to the target body site (56,116). [Pg.148]

C725, a 9 wt % nickel alloy that is further strengthened by 2 wt % tin, is used in electrical connectors and bellows. Properties are summari2ed in Table 21. The alloy has good resistance to stress relaxation at room and moderately elevated temperatures, which accounts for its use in connectors and electrical circuit wire wrap pins. [Pg.233]


See other pages where Bellows is mentioned: [Pg.939]    [Pg.61]    [Pg.418]    [Pg.55]    [Pg.10]    [Pg.129]    [Pg.354]    [Pg.140]    [Pg.311]    [Pg.178]    [Pg.65]    [Pg.66]    [Pg.66]    [Pg.66]    [Pg.92]    [Pg.97]    [Pg.20]    [Pg.22]    [Pg.22]    [Pg.23]    [Pg.23]    [Pg.23]    [Pg.24]    [Pg.35]    [Pg.300]    [Pg.371]    [Pg.371]    [Pg.372]    [Pg.406]    [Pg.377]    [Pg.566]    [Pg.72]    [Pg.486]   
See also in sourсe #XX -- [ Pg.56 , Pg.80 , Pg.149 , Pg.186 , Pg.187 ]

See also in sourсe #XX -- [ Pg.161 ]

See also in sourсe #XX -- [ Pg.161 ]

See also in sourсe #XX -- [ Pg.135 ]

See also in sourсe #XX -- [ Pg.254 ]

See also in sourсe #XX -- [ Pg.46 ]

See also in sourсe #XX -- [ Pg.78 ]

See also in sourсe #XX -- [ Pg.168 ]

See also in sourсe #XX -- [ Pg.302 , Pg.326 , Pg.650 ]

See also in sourсe #XX -- [ Pg.9 , Pg.107 , Pg.170 , Pg.174 ]

See also in sourсe #XX -- [ Pg.148 , Pg.175 ]

See also in sourсe #XX -- [ Pg.14 , Pg.42 ]

See also in sourсe #XX -- [ Pg.8 , Pg.166 ]

See also in sourсe #XX -- [ Pg.426 ]

See also in sourсe #XX -- [ Pg.850 ]




SEARCH



American Petroleum Institute Balanced-bellows pressure relief valve

American Petroleum Institute balanced-bellows pressure relief

Balanced bellows

Balanced bellows pressure

Balanced bellows pressure relief valve

Balanced bellows safety relief

Balanced bellows safety relief valve

Balanced bellows valve

Balanced-bellows PRV

Balanced-bellows relief valves

Bellow Failure

Bellow structure

Bellowing effect

Bellows cell

Bellows element

Bellows expansion joints

Bellows expansion type

Bellows gauges

Bellows joint

Bellows pressure gauge

Bellows pressure sensing element

Bellows principle

Bellows pump

Bellows sealed valves

Bellows type sensors

Bellows, Henry

Bellows, composite

Bellows, glass

Bellows, metering pump

Chest bellows disease

Couplings bellows

Equalization valves with bellows

Exhaust bellows

Expansion bellows

Metallic bellows

Pressure measurement bellows gauges

Relief balanced-bellows

Retraction bellows

Valves bellows

© 2024 chempedia.info