Balanced-bellows PRV

This is a PRV designed to minimize the effect of back pressure on its performance characteristics. [Pg.250]


Figure 2 A typical balanced-bellows PRV. [Courtesy of Tyco Valves and Controls LP]... Figure 2 A typical balanced-bellows PRV. [Courtesy of Tyco Valves and Controls LP]...
Besides reduce the backpressure influence on PRV s disk, bellows has another usage. It sometimes is used to isolate the guide, spring, and bonnet fiom the relieving fluid. It is important that balanced-bellows PRV s bonnet be vented to atmosphere, since it is part of valve s design basis. [Pg.144]

Kd equals 0.74 for PRV sizing, if manufacturer s Kd is not avmlable, Kd equals 0.62 for rupture disk sizing. Kw equals 1.0 for conventional, pilot PRV, and rupture disk sizing. For balanced-bellows PRV, use Figure 9 to estimate its value. [Pg.156]

Balanced-bellows PRVs are spring-loaded valves with a bellows or some other means of balancing the valve disk to minimize the effect of back pressme. Typical valve configurations are shown in Figure 4.3 and Figure 4.4. [Pg.256]

Balanced-bellows PRVs are not normally used if a conventional PRV is acceptable. However, some operating companies prefer to install balanced-bellows PRVs for all scenarios simply because of possible change in future service conditions. [Pg.264]

Balanced-bellows PRVs can be used for higher back pressme up to 50% back pressure without reducing the back-pressure correction factor (for a 21% overpressure situation). [Pg.264]

Balanced-bellows PRVs are normally used when the back pressure exceeds 10%. [Pg.264]

Balanced-bellows PRVs are widely used for flashing service. [Pg.264]

If there is a choice between conventional and balanced-bellows PRVs, the conventional PRVs are a better option. [Pg.264]

The flow contingency shall be the maximum contingency flow through the valve. This is the maximum capacity of the relief valve. For convenhonal and balanced-bellows PRVs, the nonrecoverable pressure drop shall not exceed 3% of the PRV set pressure. [Pg.271]

Balanced-bellows PRVs for subcritical flow are designed using Equation 4.44. The back-pressure correction factor is obtained from tiie manufacturer. [Pg.311]

Conventional PRV is not suitable Recalculate using Balanced Bellow PRV... [Pg.356]

This program has been developed for conventional and balanced-bellows PRVs. However, this program can be used for pilot-operated PRVs, too. For pilot-operated PRVs, use ... [Pg.356]


See other pages where Balanced-bellows PRV is mentioned: [Pg.265]    [Pg.250]    [Pg.256]    [Pg.264]    [Pg.264]    [Pg.307]    [Pg.311]    [Pg.316]   