Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Application guidance

ANSI/ISA-84.00.01-2004-1, Clause 9.2.3, provides two tables for defining the SIL requirements. Table 3 provides the SIL requirements in terms of PFDavg- Table 4 provides the SIL requirements in terms of Frequency of Failure (e.g., failures per hour) and defines the acceptable hazard rate for the high-demand/continuous SIF. ANSI/ISA-84.00.01-2004-1, Clause 9.2.3, states that when Table 4 is used, neither the proof-test interval nor the demand rate is used in the determination of the safety integrity level. This means that the Table 4 requirements should not be converted into PFDavg requirements, using the proof-test interval or the demand rate. Erroneous results can easily occur if a high-demand mode SIF is treated as a low-demand mode SIF, followed by incorrect use of Tables 3 and 4 (ANSI/ISA-84.00.01-2004-1 Clause 9.2.3). [Pg.162]

For high-demand cases, the equation requires more scmtiny. For example, assume that a batch controller has a mean time to demand of 14 hours (8760/14=625 demands/year) and the frequency of failure for the reactor charging controls are  [Pg.162]

1 per year, considered to have an SIL 1 rating with a proof-test interval of one year. [Pg.162]

Using the simplified equation (eq. 2), we would have the following result  [Pg.162]

This can be seen to be incorrect, as the hazard rate cannot exceed the failure rate of the SIF components. This occurred because a basic assumption of the simplified equation has been violated the mean time to demand should be greater than the test interval. In this case, the mean time to demand is 14 hours and the test interval is 1 year the opposite of what it should be. Dangerous failures are much [Pg.162]

Since each plant has a different fabrication and operational history, it is important to start the problem with a plant specific assessment that considers that history in defining the risks and actions to be taken. [Pg.101]

A fatigue assessment is conducted in the design phase in order to prevent any crack initiation. This assessment is made by using the cyclic stresses and number of cycles given in the RPVI design report. These values are determined using the estimates of the type and number of transients provided by the NSSS vendors. [Pg.102]

In the ageing management programme the followings should be considered. [Pg.102]

The following activities of the ageing management programme address stress corrosion cracking  [Pg.102]


Provide application guidance and support to the customer that teaches them how to use the product efficiently. This reduces their costs, solves a knowledge problem for them, and helps lock them into the supplier. [Pg.58]

Piezoelectric ceramics, which depend on lead compounds, are used to produce transducers and sensors which make possible ultrasound technologies used in wide-ranging medical and commercial applications, guidance and sensing systems used in defense and commerce, and in addition, new "smart materials" research projects. [Pg.387]

There is no fundamental distinction between empirical and rational the dif fer-ences lie only in the number of conditions included in xm+1..xm. We can accordingly write very generally applicable guidance without special rules for empirical versus rational measurements. (It has not escaped us that this view might greatly simplify future guidance on the estimation of uncertainty for empirical measurands). [Pg.291]

Type III DMFs. The applicable Guidance for Type III DMFs is the Guidance for Industry Container Closure Systems for Packaging Human Drugs and Biologies Chemistry, Manufacturing, and Controls Documentation and Questions and Answers. (Category 3)... [Pg.300]

BC-MWLAP Government of British Columbia, Ministry of Water, Land and Air Protection (2001). Composite samples A guide for regulators and project managers on the use of composite samples. Contaminated sites statistical applications guidance document No. 12—10. ... [Pg.26]

Format and Content of the Summary for New Drug and Antibiotic Applications. Guidance for Industry. Food and Drug Administration. February 1, 1987. [Pg.101]

FDA revokes previous Part 11 guidance and issue scope and applicability guidance... [Pg.23]

FDA (2003), Part 11 Electronic Records, Electronic Signatures — Scope and Application, Guidance for Industry (www.fda.gov). [Pg.44]

Although MEPAS applications are often data intensive, the MEPAS documentation provides both application guidance (5) and definitions and sources of information for all input parameters (6). When available, site-specific data are used. Alternative procedures are provided for estimating emission, transport, and exposure parameter values for sites using local, regional, state, and federal information sources. [Pg.201]

Droppo, J. G. Jr. Strenge, D. L. Buck, J. W. Hoopes. B. L. Brockhaus, R. D. Walter, M. B. Whelan, G. Multimedia Environmental Pollutant Assessment System (MEPAS) Application Guidance Volume 1 - User s Guide PNL-7216, Pacific Northwest Laboratory, Richland, Washington, 1989. [Pg.210]

The mechanical-power-transmission apparatus section covers all belts, pulleys, and conveyors that are used in industry. It describes which ones need to be guarded. For specific applications, guidance is given for preferred actions. [Pg.411]

It is not easy to interpret aU above mentimied legislatimi and to give uniform guidance for each country and each situatimi. The determination of adequate quality assurance measures, for example the GMP-classificati(Mi of the clean room, should be the result of a risk assessment [20]. Table 15.2 gives a practical overview of the applicable guidance and the appropriate quality assurance level when preparing radiopharmaceuticals. [Pg.314]

U.S. FDA, "Mobile Medical Applications Guidance for Industry and Food and Drug Administration Staff," 2014. [Pg.159]

It has a safety manual provided by the manufacturer that provides application guidance for the owner/operator. [Pg.197]

This annex is intended to provide application guidance regarding ANSI/ISA-84.00.01-2004-1, Clause 11.3, Requirements for system behavior on detection of a fault. This clause addresses the nature of response associated with three separate cases ... [Pg.223]

Safety instrumented functions (SIF) are assigned a safety integrity level (SIL) and a mode of operation (continuous or demand) during the H RA. These are recent requirements and application guidance is limited at best. [Pg.249]

In 2002, Dong et al. (2003) published a study on MW ablation in a large cohort of 234 patients with 339 HCC lesions treated via MW coagulation therapy with up to 5-year survival rates. Percutaneous interventional treatment was performed with ultrasonographic applicator guidance. A 89.3% rate of technically complete ablations was reported, with a lack of enhancing residual tumor tissue in immediate follow-up CT or MR scan. In 194 nodules, additional post-treatment biopsies were carried out with an absence of viable tumor cells in 180 nodules (92.8%). The 3-year survival rate was 72.9%, the 5-year survival rate 56.7%. No clinical reports have been published so far for the 915-MHz device. [Pg.27]

The AEGL process does not include specific implementing or application guidance, and specific approaches for using the values are left to the discretion of risk managers and appropriafe authorities (NRC, 2001). Nevertheless, AEGL application is already broad and continues to expand. [Pg.101]


See other pages where Application guidance is mentioned: [Pg.105]    [Pg.176]    [Pg.101]    [Pg.56]    [Pg.210]    [Pg.583]    [Pg.153]    [Pg.26]    [Pg.162]    [Pg.394]    [Pg.97]    [Pg.101]    [Pg.158]   


SEARCH



Applicable to Nuclear Criticality Safety Guidance

Application methodological guidance

Guidance

© 2024 chempedia.info