Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Aerosol temperature

The SCIAMACHY utilises near simultaneous limb and nadir measurements of the scattered light in the atmosphere between 240 and 2400 nm to determine the amounts and distributions of tropospheric constituents. The target species and parameters are 03, N02, N20, BrO, CO, H20, S02, CO, C02, CH4, aerosols temperature and pressure. For the long-lived gases such as N20, CH4 and C02 the scientific objective is to measure the small gradients, which define source and sink regions. [Pg.322]

Besides gases and aerosols, temperature is another critical factor that acts in combinahon with relative humidity to determine the wetness conditions on a metal surface. Hence, in order to obtain an overall picture of surface wetness, climate and pollution should be considered together. Based on dose-response functions obtained from field exposures [91], the most common temperature dependence for metals is illustrated by curve "a" in Figure 15.11, showing that the time of wetness has a maximum at round 10°C. The explanahon is that at lower temperatures corrosion increases with temperature due to increase of time of wetness while, at higher temperatures corrosion decreases due to faster evaporation of moisture after rain or condensation periods. [Pg.692]

Littau KAefa/1993 A luminescent silicon nanocrystal colloid via a high temperature aerosol reaction J. Phys. Chem. 97 1224... [Pg.2914]

Following the movement of airborne pollutants requires a natural or artificial tracer (a species specific to the source of the airborne pollutants) that can be experimentally measured at sites distant from the source. Limitations placed on the tracer, therefore, governed the design of the experimental procedure. These limitations included cost, the need to detect small quantities of the tracer, and the absence of the tracer from other natural sources. In addition, aerosols are emitted from high-temperature combustion sources that produce an abundance of very reactive species. The tracer, therefore, had to be both thermally and chemically stable. On the basis of these criteria, rare earth isotopes, such as those of Nd, were selected as tracers. The choice of tracer, in turn, dictated the analytical method (thermal ionization mass spectrometry, or TIMS) for measuring the isotopic abundances of... [Pg.7]

To examine a sample by inductively coupled plasma mass spectrometry (ICP/MS) or inductively coupled plasma atomic-emission spectroscopy (ICP/AES), it must be transported into the flame of a plasma torch. Once in the flame, sample molecules are literally ripped apart to form ions of their constituent elements. These fragmentation and ionization processes are described in Chapters 6 and 14. To introduce samples into the center of the plasma flame, they must be transported there as gases or finely dispersed droplets of a solution or as fine particulate matter (aerosol). The various methods of sample introduction are described here in three parts — A, B, and C Chapters 15, 16, and 17 — to cover gases, solutions (liquids), and solids. Some types of sample inlets are multipurpose and can be used with gases and liquids or with liquids and solids, but others have been designed specifically for only one kind of analysis. However, the principles governing the operation of inlet systems fall into a small number of categories. This chapter deals specifically with substances that are normally solids at ambient temperatures. [Pg.109]

Suffice it to say at this stage that the surfaces of most solids subjected to such laser heating will be heated rapidly to very high temperatures and will vaporize as a mix of gas, molten droplets, and small particulate matter. For ICP/MS, it is then only necessary to sweep the ablated aerosol into the plasma flame using a flow of argon gas this is the basis of an ablation cell. It is usual to include a TV monitor and small camera to view the sample and to help direct the laser beam to where it is needed on the surface of the sample. [Pg.112]

The previous discussion has centered on how to obtain as much molecular mass and chemical structure information as possible from a given sample. However, there are many uses of mass spectrometry where precise isotope ratios are needed and total molecular mass information is unimportant. For accurate measurement of isotope ratio, the sample can be vaporized and then directed into a plasma torch. The sample can be a gas or a solution that is vaporized to form an aerosol, or it can be a solid that is vaporized to an aerosol by laser ablation. Whatever method is used to vaporize the sample, it is then swept into the flame of a plasma torch. Operating at temperatures of about 5000 K and containing large numbers of gas ions and electrons, the plasma completely fragments all substances into ionized atoms within a few milliseconds. The ionized atoms are then passed into a mass analyzer for measurement of their atomic mass and abundance of isotopes. Even intractable substances such as glass, ceramics, rock, and bone can be examined directly by this technique. [Pg.284]

To assist evaporation of solvent, the argon stream carrying the aerosol can be passed through a heated tube called a desolvation chamber, operated at temperatures up to about 150°C. [Pg.400]

Alkali metal haHdes can be volatile at incineration temperatures. Rapid quenching of volatile salts results in the formation of a submicrometer aerosol which must be removed or else exhaust stack opacity is likely to exceed allowed limits. Sulfates have low volatiHty and should end up in the ash. Alkaline earths also form basic oxides. Calcium is the most common and sulfates are formed ahead of haHdes. Calcium carbonate is not stable at incineration temperatures (see Calcium compounds). Transition metals are more likely to form an oxide ash. Iron (qv), for example, forms ferric oxide in preference to haHdes, sulfates, or carbonates. SiHca and alumina form complexes with the basic oxides, eg, alkaH metals, alkaline earths, and some transition-metal oxidation states, in the ash. [Pg.58]

Pulsed spark sources, in which the material to be analyzed is part of one electrode, are used for semiquantitative analyses. The numerous and complex processes involved in spark discharges have been studied in detail by time- and space-resolved spectroscopy (94). The temperature of d-c arcs, into which the analyte is introduced as an aerosol in a flowing carrier gas, eg, argon, is approximately 10,000 K. Numerous experimental and theoretical studies of stabilized plasma arcs are available (79,95). [Pg.114]

Ammonia has low miscibility in mineral oils, alkylbenzenes, and polyol ester lubricants, particularly at low temperatures. A typical ammonia system uses a coalescing separator that removes all oil in droplet or aerosol form and drains it back to the compressor. Sometimes separators are equipped with some means of cooling the discharge gas to condense any oil that is discharged as a vapor. [Pg.69]

Small amounts of sulfuric acid mist or aerosol are always formed in sulfuric acid plants whenever gas streams are cooled, or SO and H2O react, below the sulfuric acid dew point. The dew point varies with gas composition and pressure but typically is 80—170°C. Higher and lower dew point temperatures are possible depending on the SO concentration and moisture content of the gas. Such mists are objectionable because of both corrosion in the process and stack emissions. [Pg.183]

Standardized techniques atomic absorption (AAA) and photometric (FMA) of the analysis and designed by us a technique X-Ray fluorescence of the analysis (XRF) for metals definition in air of cities and the working areas of plants to production of non-ferrous metals are applied. The samples of aerosols were collected on cellulose (AFA-HA) and perchlorovinyl (AFA-VP and FPP) filters (Russia). The techniques AAA and FMA include a stage of an acid-temperature ashing of a loaded filter or selective extraction of defined elements from filter by approaching dissolvent. At XRF loaded filters were specimens. [Pg.207]

Other lesser mechanisms that result in aerosol removal by filters are (1) gravitational settling due to the difference in mass of the aerosol and the carrying gas, (2) thermal precipitation due to the temperature gradient between a hot gas stream and the cooler filter medium which causes the particles to be bombarded more vigorously by the gas molecules on the side away from the filter element, and (3) Brownian deposition as the particles are bombarded with gas molecules that may cause enough movement to permit the aerosol to come in contact with the filter element. Browruan motion may also cause some of the particles to miss the filter element because they are moved away from it as they pass by. For practical purposes, only the three mechanisms shown in Fig. 29-1 are normally considered for removal of aerosols from a gas stream. [Pg.463]


See other pages where Aerosol temperature is mentioned: [Pg.36]    [Pg.397]    [Pg.561]    [Pg.36]    [Pg.397]    [Pg.561]    [Pg.35]    [Pg.7]    [Pg.113]    [Pg.114]    [Pg.137]    [Pg.379]    [Pg.413]    [Pg.400]    [Pg.433]    [Pg.274]    [Pg.25]    [Pg.57]    [Pg.496]    [Pg.497]    [Pg.114]    [Pg.403]    [Pg.317]    [Pg.317]    [Pg.193]    [Pg.478]    [Pg.291]    [Pg.303]    [Pg.398]    [Pg.521]    [Pg.506]    [Pg.1606]    [Pg.2057]    [Pg.2382]    [Pg.464]    [Pg.29]    [Pg.221]    [Pg.246]    [Pg.466]    [Pg.635]   
See also in sourсe #XX -- [ Pg.13 ]




SEARCH



Aerosol decomposition process, high temperature

High temperature aerosol decomposition catalyst synthesis

High-temperature aerosol decomposition

© 2024 chempedia.info