Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Adsorption systems recommendation

Carbon molecular sieve adsorption desorption at 350°C into a cryogenically cooled troop flash evaporated onto a capillary column GC/MS system recommended sample volume 10 L flow rate 100 mL/min. [Pg.349]

Hexachloroethane is considered to be one of the more toxic chlorinated hydrocarbons. The 1991 ACGIH recommended time-weighted average (TWA) for hexachloroethane was 1 ppm or 10 mg /m of air. Skin adsorption is a route of possible exposure ha2ard. The primary effect of hexachloroethane is depression of the central nervous system (147). Pentachloroethane and tetrachloroethylene are primary metaboHtes of hexachloroethane in sheep (148). [Pg.15]

In addition to assessing nonspecific adsorption with a simple system such as just described, it is recommended that postwash-cycle testing be performed with the same qualification methods and criteria used to evaluate new column... [Pg.84]

Because of the problems encountered with the water system, the use of aliphatic alcohols, ie.g., methanol, ethanol, and isopropanol, as modifiers of the adsorption strength has been recommended (44. 45. 50. 51). Usually, between 0.01 and 0.5% (v/v) alcohol is added to the eluent. As an example, the k values for the benzyl alcohols on a silica column are in the same range when eluted with dichloromethane containing either 0.1% water (50% water-saturated) or 0.15% methanol or 0.3% isopropanol (45). The preparation and preservation of these alcohol-eluent mixtures is accompanied by problems similar to those discussed with water-modified eluents. Also, column equilibration is slow (44). The efficiency of columns operated with alcohol-modified eluents is generally lower than that of water-modulated eluent system. At some alcohol concentrations, distorted peaks with tailing or frontal asymmetry have been observed 44), but olhei workers using another silica could not verify this observa tion (61). [Pg.44]

Wall adsorption, although significant mainly in metallic volumetric systems, appears not to result in major problems if a suitably careful calibration is performed. Rapid transfer of heat from the sample to the cell wall is recommended [164],... [Pg.224]

Abstract To design an adsorption cartridge, it is necessary to be able to predict the service life as a function of several parameters. This prediction needs a model of the breakthrough curve of the toxic from the activated carbon bed. The most popular equation is the Wheeler-Jonas equation. We study the properties of this equation and show that it satisfies the constant pattern behaviour of travelling adsorption fronts. We compare this equation with other models of chemical engineering, mainly the linear driving force (LDF) approximation. It is shown that the different models lead to a different service life. And thus it is very important to choose the proper model. The LDF model has more physical significance and is recommended in combination with Dubinin-Radushkevitch (DR) isotherm even if no analytical solution exists. A numerical solution of the system equation must be used. [Pg.159]

To establish the molecular thermodynamic model for uniform systems based on concepts from statistical mechanics, an effective method by combining statistical mechanics and molecular simulation has been recommended (Hu and Liu, 2006). Here, the role of molecular simulation is not limited to be a standard to test the reliability of models. More directly, a few simulation results are used to determine the analytical form and the corresponding coefficients of the models. It retains the rigor of statistical mechanics, while mathematical difficulties are avoided by using simulation results. The method is characterized by two steps (1) based on a statistical-mechanical derivation, an analytical expression is obtained first. The expression may contain unknown functions or coefficients because of mathematical difficulty or sometimes because of the introduced simplifications. (2) The form of the unknown functions or unknown coefficients is then determined by simulation results. For the adsorption of polymers at interfaces, simulation was used to test the validity of the weighting function of the WDA in DFT. For the meso-structure of a diblock copolymer melt confined in curved surfaces, we found from MC simulation that some more complex structures exist. From the information provided by simulation, these complex structures were approximated as a combination of simple structures. Then, the Helmholtz energy of these complex structures can be calculated by summing those of the different simple structures. [Pg.211]

In a first part of this section, the synchrotron methods are described as they might still not be so common to many scientists in the field of corrosion research. The scanning methods are discussed only briefly, as they have been introduced by numerous papers on in situ studies of the structure of electrode surfaces. Several good reviews are found in literature, and are recommended to the interested reader they describe the application of STM to adsorption and Under Potential Deposition (UPD) metal dissolution and deposition and nano-structuring by deposition of small metal clusters [103-105]. In a following part, results are presented for a number of systems that have been studied in detail with special attention to Cu. [Pg.344]

Snyder7 has thoroughly studied adsorption chromatography, and some of his results were summarized in Chapter 3. He recommends covering 50 to 100% of the stationary solid surface with a monolayer of water. This requires up to 0.04 g of water per 100 m2 of surface, or about 4 to 15% water added to the stationary phase. This process is not as easy as it sounds, and a long time is required for the system to come to equilibrium. This necessity to control the solid surface activity coupled with the pH limitation mentioned earlier has contributed to the decreased use of LSC for analytical separations although it is still popular for preparative LC. [Pg.87]

In the single-flow technique, a carrier gas containing the molecules to be adsorbed pass continuously over the catalyst. The flow method of determining gas adsorption has the advantages that no vacuum system is required and no dead volume corrections need to be made. The method is also rapid and easy to use. Disadvantages are the need to use very pure carrier gases, and the fact that for slow or activated adsorption processes equilibrium adsorption may be difficult to determine. The flow method is not recommended for obtaining total isotherms. [Pg.553]


See other pages where Adsorption systems recommendation is mentioned: [Pg.530]    [Pg.113]    [Pg.86]    [Pg.417]    [Pg.73]    [Pg.1522]    [Pg.273]    [Pg.346]    [Pg.169]    [Pg.70]    [Pg.1045]    [Pg.446]    [Pg.738]    [Pg.303]    [Pg.432]    [Pg.409]    [Pg.139]    [Pg.566]    [Pg.227]    [Pg.3]    [Pg.172]    [Pg.11]    [Pg.50]    [Pg.156]    [Pg.639]    [Pg.9]    [Pg.508]    [Pg.26]    [Pg.257]    [Pg.355]    [Pg.91]    [Pg.212]    [Pg.315]    [Pg.392]    [Pg.378]    [Pg.119]    [Pg.117]    [Pg.377]    [Pg.107]    [Pg.119]    [Pg.303]   
See also in sourсe #XX -- [ Pg.200 , Pg.201 ]