Volume of sample

Values of pore volume of samples of porous silica, determined by ethanol titration (v (EtOH)) and by mercury porosimetry (v (Hg, i) and v (Hg, ii)) ... [Pg.182]

The time needed to complete an analysis for a single sample is often fairly similar from method to method. This is somewhat misleading, however, because much of this time is spent preparing the solutions and equipment needed for the analysis. Once the solutions and equipment are in place, the number of samples that can be analyzed per hour differs substantially from method to method. This is a significant factor in selecting a method for laboratories that handle a high volume of samples. [Pg.44]

The volume of sample that can be passed through a solid sorbent before the analytes are no longer retained. [Pg.196]

Procedure. Select a volume of sample requiring less than 15 mL of titrant to keep the analysis time under 5 min and, if necessary, dilute the sample to 50 mL with distilled water. Adjust the pH by adding 1-2 mL of a pH 10 buffer containing a small amount of Mg +-EDTA. Add 1-2 drops of indicator, and titrate with a standard solution of EDTA until the red-to-blue end point is reached. [Pg.326]

Furthermore, the extent to which we can effect a separation depends on the distribution ratio of each species in the sample. To separate an analyte from its matrix, its distribution ratio must be significantly greater than that for all other components in the matrix. When the analyte s distribution ratio is similar to that of another species, then a separation becomes impossible. For example, let s assume that an analyte. A, and a matrix interferent, I, have distribution ratios of 5 and 0.5, respectively. In an attempt to separate the analyte from its matrix, a simple liquid-liquid extraction is carried out using equal volumes of sample and a suitable extraction solvent. Following the treatment outlined in Chapter 7, it is easy to show that a single extraction removes approximately 83% of the analyte and 33% of the interferent. Although it is possible to remove 99% of A with three extractions, 70% of I is also removed. In fact, there is no practical combination of number of extractions or volume ratio of sample and extracting phases that produce an acceptable separation of the analyte and interferent by a simple liquid-liquid extraction. [Pg.544]

Hydrodynamic injection uses pressure to force a small portion of the sample into the capillary tubing. To inject a sample hydrodynamically a difference in pressure is applied across the capillary by either pressurizing the sample vial or by applying a vacuum to the destination reservoir. The volume of sample injected, in liters, is given by the following equation... [Pg.602]

A hydrodynamic injection is made by applying a pressure difference of 2.5 X 10 Pa (approximately 0.02 atm) for 2 s to a 75-cm long capillary tube with an internal diameter of 50 Jtm. Assuming that the buffer solution s viscosity is 10 kg m s what volume of sample is injected ... [Pg.602]

Source Adapted from Baker, D. R. Capillary Electrophoresis. Wiley-Interscience New York, 1995. "Concentration depends on the volume of sample injected. [Pg.605]

Caffeine, benzoic acid, and aspartame in soft drinks are analyzed by three methods. Using several methods to analyze the same sample provides students with the opportunity to compare results with respect to accuracy, volume of sample required, ease of performance, sample throughput, and detection limit. [Pg.614]

Chemical kinetic methods of analysis continue to find use for the analysis of a variety of analytes, most notably in clinical laboratories, where automated methods aid in handling a large volume of samples. In this section several general quantitative applications are considered. [Pg.636]

Although Vickers and DPH microhardness tests should yield the same numerical results on a given material, such is not always the case. Much of the observed variance may be a function of differences ia the volume of sample material displaced by the macro and micro iadentations. [Pg.467]

Another standard test, which is much simpler and more convenient, is the membrane filter technique. A suitable volume of sample is filtered through a sterile, 0.45-p.m membrane filter. The filter is placed in a petri dish containing a specific growth medium (M-Endo nutrient broth, M-Endo medium) and incubated for 24 h at 35°C. If after this time the colonies show the characteristic green sheen, this is taken as positive evidence for the presence of the coliform group (see Water, sewage). [Pg.233]

Fig. 3. Schematic diagram of a dark field system for measuriag the light scatteriag by a spherical red blood cell where V = volume of sample and HC = hemoglobin concentration. Optical flow cell system having double-angular interval detection at angles 9 and 02. Fig. 3. Schematic diagram of a dark field system for measuriag the light scatteriag by a spherical red blood cell where V = volume of sample and HC = hemoglobin concentration. Optical flow cell system having double-angular interval detection at angles 9 and 02.
Specific Gravity. The specific gravity is determined by weighing a known volume of sample in a Lipkin bicapiHary pycnometer as described in ASTM Designation D941. [Pg.35]

Continuously operated, small-scale or pilot-plant thickeners, ranging from 75 mm diameter by 400 mm depth to several meters in diameter, are also effectively used for sizing hill-scale equipment. This approach requires a significantly greater volume of sample, such as... [Pg.1680]

As atomic fluorescence spectrometer a mercury analyzer Mercur , (Analytik-Jena, Germany) was used. In the amalgamation mode an increase of sensitivity by a factor of approximately 7-8 is obtained compared with direct introduction, resulting in a detection limit of 0,09 ng/1. This detection limit has been improved further by pre-concentration of larger volumes of samples and optimization of instrumental parameters. Detection limit 0,02 ng/1 was achieved, RSD = 1-6 %. [Pg.171]

Volume overload results from too large a volume of sample being placed on the column, and this effect will be discussed later. It will be seen that volume overload does not, in itself, produce asymmetric peaks unless accompanied by mass overload, but it does broaden the peak. Mass overload, however, frequently results in a nonlinear adsorption isotherm. However, the isotherm is quite different from the Langmuir isotherm and is caused by an entirely different phenomenon. [Pg.177]

Having established that a finite volume of sample causes peak dispersion and that it is highly desirable to limit that dispersion to a level that does not impair the performance of the column, the maximum sample volume that can be tolerated can be evaluated by employing the principle of the summation of variances. Let a volume (Vi) be injected onto a column. This sample volume (Vi) will be dispersed on the front of the column in the form of a rectangular distribution. The eluted peak will have an overall variance that consists of that produced by the column and other parts of the mobile phase conduit system plus that due to the dispersion from the finite sample volume. For convenience, the dispersion contributed by parts of the mobile phase system, other than the column (except for that from the finite sample volume), will be considered negligible. In most well-designed chromatographic systems, this will be true, particularly for well-packed GC and LC columns. However, for open tubular columns in GC, and possibly microbore columns in LC, where peak volumes can be extremely small, this may not necessarily be true, and other extra-column dispersion sources may need to be taken into account. It is now possible to apply the principle of the summation of variances to the effect of sample volume. [Pg.194]

Consider a total of (p) plate volumes of pure mobile phase are injected onto the column followed by a further (v) plate volumes of equilibrated mobile phase. After the injection of (r) plate volumes of pure mobile phase, the new concentration of solute in plate 1 will be eluted by a further (p-r) plate volumes of sample followed by (v) plate volumes of equilibrated mobile phase. Therefore, the concentration of solute leaving the (n)th plate due to the (r)th volume of pure mobile phase will be... [Pg.198]

Let the volume of sample injected be (Vi) ml, then the charge measured in plate... [Pg.200]

The maximum allowable dispersion will include contributions from all the different dispersion sources. Furthermore, the analyst may frequently be required to place a large volume of sample on the column to accommodate the specific nature of the sample. The peak spreading resulting from the use of the maximum possible sample volume is likely to reach the permissible dispersion limit. It follows that the dispersion that takes place in the connecting tubes, sensor volume and other parts of the detector must be reduced to the absolute minimum and, if possible, kept to less than 10% of that permissible (i.c.,1 % of the column variance) to allow large sample volumes to be used when necessary. [Pg.290]

Consider the separation depicted in Figure 1. It is assumed that the pair of solutes represent the elution of the solute of interest and its nearest neighbor. Now, when the sample volume becomes extreme, the dispersion that results from column overload, to the first approximation, becomes equivalent to the sample volume itself as the sample volume now contributes to the elution of the solutes. Thus, from Figure 1, the peak separation in milliliters of mobile phase will be equivalent to the volume of sample plus half the sum of the base widths of the respective peaks. [Pg.421]

MPN index Most Probable Number of coliform-group organisms per unit volume of sample water. Expressed as a density or population of organisms per 100 mL of sample water. [Pg.619]

The diameter of the column is selected from the volume of sample that is to be processed. As a rule of thumb the maximum productivity is obtained at a sample volume of 2-6% of the bed volume in preparative gel filtration on a 50-/rm chromatographic medium (Hagel et al., 1989). Thus, the required column diameter is calculated from the bed volume needed to cope with the sample volume and the column length needed to give the resolution desired. [Pg.62]


See other pages where Volume of sample is mentioned: [Pg.688]    [Pg.165]    [Pg.264]    [Pg.312]    [Pg.340]    [Pg.361]    [Pg.414]    [Pg.416]    [Pg.493]    [Pg.577]    [Pg.651]    [Pg.770]    [Pg.147]    [Pg.106]    [Pg.271]    [Pg.467]    [Pg.113]    [Pg.324]    [Pg.447]    [Pg.490]    [Pg.314]    [Pg.422]    [Pg.425]    [Pg.265]    [Pg.91]    [Pg.477]    [Pg.484]   


SEARCH



Sample volume

Sampling volume