Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Verification status

With software the verification status can be denoted in the software as a comment or on records testifying its conformance with requirements. [Pg.429]

With documentation you can denote verification status either by an approval signature on the document or by a reference number, date, and issue status which is traceable to records containing the approval signatures. [Pg.429]

Control of verification status (inspection and test status) ... [Pg.8]

It may be appropriate, based upon the hazards of the materials processed, for the client company to make a final site visit during the toll shutdown activities to review the toller s methods and completeness of process termination. This review could include termination status such as removal of all hazardous wastes and verification of associated documentation, and the adequate cleanup of equipment and the process area. [Pg.139]

How do you ensure traceability of product to original material identification, quality status, and the unit responsible for both its supply and verification ... [Pg.344]

Although the status of many 3D codes makes it possible to carry out detailed scenario calculations, further work is needed. This is particularly so for 1) development and verification of the porosity/distributed resistance model for explosion propagation in high density obstacle fields 2) improvement of the turbulent combustion model, and 3) development of a model for deflagration to detonation transition. More data are needed to enable verification of the model in high density geometries. This is particularly needed for onshore process plant geometries. [Pg.381]

Working on case studies with the objective of comprehending correlations and implementing in hypotheses (hypothesis generation) is a research strategy that is entirely appropriate for the present status of itmovation research. As such an approach to research necessarily requires a rather qualitative procedure and is based only on a few case studies, from the outset there was no claim to verification in respect of quantitative significance. [Pg.96]

Measuring equipment shall be calibrated or verified at specified intervals or prior to use and adjusted as necessary. The calibration status of each piece of equipment shall be identified and records of the calibration and verification results shall be maintained. When a piece of equipment is found not to conform to requirements, the previous measuring results shall be corrected. [Pg.65]

Quality surveillance refers to the continued monitoring and verification of the status of procedures, methods, conditions, processes, products and services, and analysis of records in relation to stated references to ensure that specified requirements for quality are being met. [Pg.43]

Dynamic Data information related to individual samples or lots (e.g., test results, sample status). This will be required if the implementation is an upgrade to an existing LIMS. The process should enable the extraction, cleansing, verification, loading, and maintenance of the dynamic data from the system being replaced. Dynamic data should be held securely under change control. [Pg.532]

Companies have their own processes for patient enrollment that typically require the completion of an application and a reporting of the patient s health insurance coverage, assets, income, and liabilities. A prescription for the medication is usually required. Many programs allow enrollment over the phone, while others require written correspondence. In order to determine eligibility, many companies require verification of a patient s financial status by documents such as income tax returns, W-2 forms, social security and other benefit... [Pg.531]

Gerszten RE, Asnani A, Carr SA (2011) Status and prospects for discovery and verification of new biomarkers of cardiovascular disease by proteomics. Circ Res 109(4) 463-474. doi 10.1161/CIRCRESAHA. 110.225003... [Pg.476]

Practically all observations [241-243, 245,249, 261, 262,264] of the entropy driven brush stretching (see Eq. 59) have been performed for polystyrene brushes immersed in an identical, except for the isotopic status, PS matrix. The change in the conformational properties of the brush has been observed as a function of surface coverage o [241-243,245,249,261,262,264] and/or host matrix degree of polymerization P [241,243]. These studies were initiated in 1992 by us [241] and two other groups [249,262]. Here we resume the results of these reports focusing on the verification of the schematic conformation diagram (InP/ln N vs lno/ln N) predicted by theory [232, 239, 267] and presented in Fig. 35. [Pg.88]

Status verification—a checklist used to verify that the proper actions were taken... [Pg.83]

THE STATUS OF CHEMICAL PROLIFERATION Chemical Warfare Capabilities of Nations International Agreements and Verification Terrorism... [Pg.111]


See other pages where Verification status is mentioned: [Pg.427]    [Pg.429]    [Pg.531]    [Pg.143]    [Pg.427]    [Pg.429]    [Pg.531]    [Pg.143]    [Pg.135]    [Pg.253]    [Pg.6]    [Pg.605]    [Pg.716]    [Pg.49]    [Pg.56]    [Pg.716]    [Pg.17]    [Pg.230]    [Pg.127]    [Pg.518]    [Pg.13]    [Pg.693]    [Pg.562]    [Pg.65]    [Pg.84]    [Pg.218]    [Pg.45]    [Pg.70]    [Pg.294]    [Pg.84]    [Pg.886]    [Pg.2104]    [Pg.2458]    [Pg.203]   
See also in sourсe #XX -- [ Pg.427 ]




SEARCH



Verification

© 2024 chempedia.info