Carrythrough of BW solids with the condensate. Highly alkaline condensate Pre-boiler metal damage pH control out of balance Fouling to DA vent, check valves and FW pump... [Pg.205]

For over 20 years the tank successfully operated with a nitrogen pad to reduce moisture intrusion and a simple hinged breather vent to provide overpressure and vacuum protection. The modification (installed and completed just three days prior to the failure) provided a vent compressor and a new state-of-the-art nearly zero leakage pressure/vacuum device and some unique piping features. See Figure 2—14, which shows impulse block valve No. 4 and the vent check valve No. 2. [Pg.32]

Most small Hquid helium containers are unpressurized heat leak slowly bods away the Hquid, and the vapor is vented to the atmosphere. To prevent plugging of the vent lines with solidified air, check valves of some sort are included in the vent system. Containers used for air transportation are equipped with automatic venting valves that maintain a constant absolute pressure with the helium container in order to prevent Hquid flash losses at the lower pressures of flight altitudes and to prevent the inhalation of air as the pressure increases during the aircraft s descent. Improved super insulation has removed the need for Hquid nitrogen shielding from almost all small containers. [Pg.12]

Blockage of liquid Monitor pressure drop across vent system (e.g., effluent line due local indication, alarm or interlock) to closed valves,, Interlock valve in feed line to centrifuge results in flooding of basket and Equipment/line-up checks overflow from Remove unnecessary valves basket to solid col-. 5, lection system in base. Possibility of liquid spill. ... [Pg.64]

Check and open vents by scheduled preventive maintenance... [Pg.78]

At high pressure experiments the reactor should be installed in a pressure cell. All check valves before it, and the filter with the flow controller after it, can be kept in the vented operating room. As a minimum, the bypass valve and the flow controller must be accessible to the operator. This can be done by extended valve stems that reach through the protecting wall. Both the operating room and the pressure cell should be well ventilated and equipped by CO alarm instruments. [Pg.86]

If a check valve is used in a system without an arrestor, excessive pressure may be exerted on the system when the reversing water column is violently stopped by the check valve. If a float-type air vent is located between the check valve and the closing valve, the float could easily be ruptured. [Pg.313]

Activate steam Introduce steam to Boiler feed water Vent inerts from Check all headers. Check for... [Pg.332]

Does the ground slope Check potential vehicle run-away. Check venting and ventilation facilities. [Pg.485]

Check for underventilation caused by obstructed vents, faulty dampers or other HVAC system malfunctions, or from problems within the occupied space. Furniture, papers, or other materials can interfere with air movement around thermostats or block airflow from wall or floor-mounted registers. If office cubicles are used, a small space (i.e., two to four inches) between the bottom of the partitions and the floor may improve air circulation. [Pg.204]

Check the outdoor air intakes to see whether they are located near contaminant sources (e.g., plumbing vents, exhaust outlets, dumpsters, loading docks, or other locations where vehicles idle). See if the space containing the HVAC system is clean and dry. Examples of problems include cleaning or other maintenance supplies... [Pg.205]

If HjS is never present in the flare gas, seal water effluent should be routed through an open fuimel (to permit checking of seal water flow) to a manhole in a vented section of the oily water sewer. The water inlet to the manhole must be sealed. [Pg.276]

Whenever it is necessary to control the process level, pressure, temperature, etc., a control station is installed. A control station may be as simple as a single control valve or it may contain several control vahes, block valves, bypass valves, check valves, and drain or vent valves. [Pg.465]

TYPE B. FOR HAZARDOUS FLUIDS WITH VENT TO CHECK ISOLATION... [Pg.3]

The best way to prevent accidents such as this is to use rupture discs, which are harder to assemble incorrectly and which can be checked for correct installation after assembly. It is possible to get discs permanently attached to their vacuum supports by the manufacturer and fitted with a projecting tag, which carries the words vent side on one side. The tag also gives the pressure rating. [Pg.80]

Compressed air is often used to empty tank trucks and cars. Plastic pellets are often blown out of tank trucks. When the tank is empty, the driver vents the tank and then looks through the manhole to check that the tank is empty. One day a driver who was not regularly employed on this job started to open the manhole before releasing the pressure. When he had opened two out of five quick-release fastenings, the manhole blew open. The driver was blown off the tank top and killed. [Pg.266]

Another somewhat similar incident occurred when butadiene from a reactor flowed in the wrong direction up a line used for adding emulsifier. The check valve, which should have prevented the flow, was obstructed. The emulsifier tank was in a building and had an open vent. Butadiene came out and exploded. The explosion was heard 15 km away, but damage was minimized by the light construction of the building, w hich ruptured at the junction of the roof and walls [13]. [Pg.332]

Cascading effects Check valve Clogged (of filter) Consensus standard Conservation vent Dike, berm Discharge valve Division (in electrical area classification) Downspout Expansion joint Explosion proof Faucet... [Pg.433]

Vent and purge lines Procedure to indicate how to check if fully purged Ensure training covers symptoms of pressure in line Line pressure indicator at controls. Interlock device on line pressure. [Pg.220]

For conventional valves, pressure drop or variations in back pressure should not exceed 10% of set pressure. Because most process safety valves are sized for critical pressure conditions, the piping must accommodate the capacity required for valve relief and not have the pressure at the end of vent or manifold exceed the critical pressure. Designing for pressure 30% to 40% of critical w ith balanced valves, yields smaller pipes yet allows proper functioning of the valve. The discharge line size must not be smaller than the valve discharge. Check the manufacturer for valve performance under particular conditions, especially with balanced valves w hich can handle up to 70% to 80% of set pressure as back pressure. [Pg.431]

Closed-position indicators on the valves usually satisfy a system check . These show that the valves are nominally in the closed position but do not actually prove that there is no leakage. A proving system can be met by various systems which prove the soundness of the upstream and downstream safety shut-off valves by sequential pressurization, evacuation, mechanical over-travel with limit switches and a normally open vent valve, or other means. [Pg.281]

Blowdown from the boiler(s) should always be taken to either a blowdown sump or blowdown vessel before discharging into drains. Both should be adequately sized to give cooling by dilution and be fitted with vent pipes to dissipate pressure safely. The boiler(s) should have independent drain lines for the main manually operated blowdown valve and the drains from a continuous blowdown system. Where more than one boiler is connected to either system the line should be fitted with a check or secondary valve capable of being locked. [Pg.361]

Steam service, 426 Type, 400 Valves, parts, 412 Pressure-vacuum relief, 466 Calculations, 469 Emergency venting, 476-479 Equipment (valves), 468, 478, 480 Fire exposure, 479 Free air, 469, 474 Specification work sheet, 481 Thermal oulbreathing, 468, 469 Vacuum inbreathing, 468, 469, 475 Process check list, 35 Process design organization, 1, 2 Calculations, 37-39 Costs, 43 Manhours, 40-43 Scope, 2... [Pg.629]

Check the DA original design drawing. Check the position of all inlets, outlets, and baffles. Check to see if any unauthorized modifications have taken place, such as additional vent openings. The vent... [Pg.106]

In addition, the solids may cause fouling problems such as reduced deaerator venting, sticking check valves, and blocked feed pump. [Pg.203]

Scale and corrosion debris transport results in FW line/feed pump blockages Impingement and erosion Poor deaerator venting Sticking check valves Fe, Cu, Ni, Zn, Cr oxides Crystalline magnetite... [Pg.302]

Check automatic air vents for water leaks, especially if they pass directly to a drain. [Pg.660]