Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Value Diagnostics

In outlier data analysis, we are particularly concerned with also a specific x,-value s leverage and influence on the rest of the data. The leverage value, is equivalent to ha, the diagonal hat matrix, as previously discussed. We will use the term, h, as opposed to ha, when the computation is not derived from the hat matrix used extensively in multivariate regression. The leverage value measures the distance a specific x,y value is from x, or the mean of all the x values. For, F, = /3o + jSiXi - - , , without correlation between any of the x.j variables, the leverage value for the ith observation is of the form  [Pg.311]

This requires that any correlation between the independent x variables is addressed prior to outlier data analysis. Also, all of the Xi variables must be centered, Xj-Xi for a mean of 0 in order to use this procedure. [Pg.311]

Hoaglin and Welsch (1978) recommend that the researcher closely evaluate any observation where h,- 2 k + l)/n. [Pg.312]

An Fi value can be computed for each value in a regression data set by means of [Pg.312]

However, the critical value leverage table (Table H) wiU provide this value at a = 0.10, 0.05, and 0.01 n = sample size and A = number of b, predictors, excluding bo(k=, for linear regression). [Pg.313]


The success and utility of Hammett plots, and the realisation that they are often of most value diagnostically when they do indeed diverge from linearity, has emboldened a number of workers to seek, with suitable modifications, to extend their scope to a much wider range of compounds. The most general and successful of these extensions was proposed by Taft. [Pg.383]

It would be of great benefit to the pathologist if a colour Polaroid shot was enclosed with each sample of laparoscopic material obtained by liver biopsy -in addition to laboratory values, diagnostic issue in question and description of the liver surface. In evaluating the liver biopsy, the pathologist should be aware of the traditional dual assessment of an organ macroscopy + histology. [Pg.157]

A consolidated approach on how to acquire and present MS data using various instmments must be sought and agreed upon. Numerical values diagnostic in structure elucidation must be defined and extracted from experimental data in a reliable and reproducible fashion. [Pg.337]

The typical safety certified smart positioned would, automatieally or on operator request, perform value response testing routines including partial closure tests to exereise a shutdown valve. Data returned to the DCS allows valve condition to be checked against reference values. Diagnostic tests within the positioner improve the eoverage factor for dangerous failures. [Pg.227]

Consider the problem of finding a function (or vector) go given the values of the vector valued diagnostic. [Pg.159]

Transmitters were supplemented with out of range and improper output value diagnostics in the SIS and BPCS logic solvers. [Pg.53]

In the Table 2 presented the actual conventional distribution of different physic diagnostic methods relative to the solution of this or that task of technogenic, social-economic, ecological and medical safety. In the table the relative average sales values of corresponding technique in the world is presented as well. [Pg.915]

Studies on covalent hydration of N-heterocycles (67AG(E)919,76AHC(20)117) have revealed the diagnostic value of alkyl substituents in structural assignments due to their steric hindrance effects in addition reactions. C-Methyl substituents are therefore also considered as molecular probes to solve fine-structural problems in the pteridine field. The derivatives... [Pg.265]

As during diagnostics the major is a selectivity of the suggested devices, the electrode selectivity factors were defined by fixed preventing ion method. As preventing used one polymeric substance to another and synthetic washing means Lotus and OMO that contains cation SAS. The received values of selectivity factors varies in l,l-10 -2,2-10 interval. [Pg.108]

Figure 18.24(b) illustrates the use of a leakage current monitor. The instrument can be used to display or monitor on a computer remotely and store data at intervals as required to provide diagnostic information. Now it is easier to take corrective measures in time. The instrument can also be programmed to give an alarm at a preset value of I, when the actual operating conditions exceed this. [Pg.619]


See other pages where Value Diagnostics is mentioned: [Pg.449]    [Pg.311]    [Pg.318]    [Pg.362]    [Pg.162]    [Pg.449]    [Pg.311]    [Pg.318]    [Pg.362]    [Pg.162]    [Pg.634]    [Pg.694]    [Pg.561]    [Pg.741]    [Pg.42]    [Pg.436]    [Pg.474]    [Pg.383]    [Pg.17]    [Pg.516]    [Pg.538]    [Pg.62]    [Pg.161]    [Pg.324]    [Pg.9]    [Pg.12]    [Pg.50]    [Pg.287]    [Pg.704]    [Pg.735]    [Pg.786]    [Pg.212]    [Pg.31]    [Pg.668]    [Pg.348]    [Pg.732]    [Pg.566]    [Pg.68]    [Pg.146]    [Pg.183]    [Pg.561]    [Pg.741]   


SEARCH



Diagnostic value

Diagnostic value

Residuals diagnostic value

© 2024 chempedia.info